freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

北京市國(guó)際大廈空調(diào)設(shè)計(jì)說明書-wenkub.com

2025-07-31 01:21 本頁(yè)面
   

【正文】 s development. But in the construction energy consumption, uses in passing air conditioning the energy consumption to occupy the construction energy consumption warmly 30%50%, also is rising year by year. Increases unceasingly along with the average per person floor space, passes the airconditioning system warmly the widespread application, will use in passing the airconditioning system the energy consumption further to increase warmly. This will be able to enable the source supply and demand contradictory further intensification inevitably.On the other hand, existing basically passed the energy which the airconditioning system used is warmly the high grade nonrenewable energy, in which electrical energy has accounted for the absolute proportion. To these energy massive uses, causes the earth resource to be day by day deficient, simultaneously also brings the serious environment question, like in our country39。 value and the support, then is realizes the large scale energy conservation, produces the remarkable environment and the social efficiency, the impetus economy development guarantee. Key word: HVAC。PVC/NBR橡塑發(fā)泡保溫板、管殼(難燃B1級(jí))~。 保溫材料的選擇計(jì)算 保溫材料的選擇空調(diào)冷熱水管、風(fēng)管、凝結(jié)水管和屋面冷卻水管均需保溫。1) ,而補(bǔ)水量為制冷機(jī)配套循環(huán)水泵流量的1%到3%。根據(jù)水泵工作時(shí),取流量?jī)?chǔ)備系數(shù) =。如果水泵從低位水箱吸水,吸水管上還應(yīng)該安裝真空表。 冷凍水泵配管布置進(jìn)行水泵的配管布置時(shí),應(yīng)注意以下幾點(diǎn):1.安裝軟性接管:在連接水泵的吸入管和壓出管上安裝軟性接管,有利于降低和減弱水泵的噪聲和振動(dòng)的傳遞。環(huán)路中各種管件的水壓降和沿程壓降之和按估算法計(jì)算:水系統(tǒng)為異程式。 Hmax (76)式中:H——水泵揚(yáng)程,m; Hmax——水泵所承擔(dān)的最不利環(huán)路的水壓降,mH2O; ——揚(yáng)程儲(chǔ)備系數(shù)取=。1)水泵流量的確定單臺(tái)冷水機(jī)組的額定水流量為60 m 3/h , L/s。管長(zhǎng)由所需連接的管的接頭個(gè)數(shù)、管徑及間距確定,兩相鄰管接頭中心線間距為兩管外徑+1200mm,兩邊管接頭中心線距集管斷面宜為管外徑+60mm?!妫徊煌瑱C(jī)型冷凝器單位產(chǎn)冷量的散熱量,可按下式估算:對(duì)于吸收式制冷機(jī)組: (74)式中:——冷水機(jī)組的制冷量,kW;故=3600單臺(tái)冷卻塔冷卻水量W′=W/2= m3/h故選擇2臺(tái)河南開通廠家生產(chǎn)的BNGD100型圓形逆流式中溫低噪聲冷卻塔,中溫系列工況,進(jìn)塔水溫為40℃,出塔水溫為32℃,水溫差為8℃,主要技術(shù)參數(shù)見下:型號(hào)冷卻水量(m3/h)風(fēng)量(m3/h)風(fēng)機(jī)直徑(mm)電機(jī)功率(kw)進(jìn)水壓力(104Pa)BNGD1001006500020003 集水器和分水器的選擇供水集管又稱分水器(或分水缸),回水集管又稱集水器(或回水缸),它們都是一段水平安裝的大管徑鋼管。 水處理裝置的選擇水處理裝置中以安裝軟化水設(shè)備最好,但價(jià)格高,占地面積大,電子水處理裝置是近年來應(yīng)用較好的一種水處理裝置。因此,濕式冷卻塔需要有供給的水源。用這種方式冷卻的稱為濕式冷卻塔?!? ——冷凍水的出口溫度,7℃;——為冷凍水的入口溫度,12℃; 冷卻塔的選擇 冷卻塔的冷卻原理制冷系統(tǒng)產(chǎn)生的熱量,必須導(dǎo)走并耗散掉。進(jìn)行技術(shù)經(jīng)濟(jì)比較后,宜優(yōu)先采用能量調(diào)節(jié)自動(dòng)化程度較高的冷水機(jī)組,本設(shè)計(jì)選用直燃型溴化鋰吸收式冷熱水機(jī)組。選擇冷水機(jī)組時(shí),應(yīng)根據(jù)建筑物用途、冷水溫度、以及電源、水源和熱源等情況,從初投資和運(yùn)行費(fèi)用進(jìn)行技術(shù)經(jīng)濟(jì)比較確定。綜合以上因素,本設(shè)計(jì)選用水冷機(jī)組??照{(diào)系統(tǒng)冷熱源設(shè)計(jì)的合理與否會(huì)直接影響空調(diào)系統(tǒng)是否能正常經(jīng)濟(jì)運(yùn)行。其它水平支干管,沿水流方向,且不允許有積水部位;2)冷凝水管道宜采用聚乙烯塑料管或鍍鋅鋼管,不宜采用焊接鋼管。=178。并將總局部阻力系數(shù)填入水管水力計(jì)算表?,F(xiàn)以一層供(回)水管為例說明基本計(jì)算步驟:1)選擇最不利管路123456789101112。“為了減小風(fēng)機(jī)盤管水系統(tǒng)的管徑,管路設(shè)計(jì)時(shí)通常選用較大的比摩,一般取120~400Pa/m,小管徑取大些的數(shù)值,大管徑取小些的數(shù)值。4摩擦阻力: Pa:該管段的局部阻力系數(shù):∑ξ=則局部阻力為 Pa總阻力為: Pa同理計(jì)算其他各管段的局部阻力及沿程阻力和局部阻力,進(jìn)而求得總阻力。衛(wèi)生間排風(fēng)由各換氣扇的排風(fēng)管集中到排風(fēng)豎井, 通過排風(fēng)豎井將排氣扇排出的氣體排至室外。=夏季工況送風(fēng),= m/s m/s的要求。)189。]=,,則散流器的有效流通面積為F=()178。本工程一層至四層采用風(fēng)機(jī)盤管+獨(dú)立新風(fēng)的空調(diào)系統(tǒng),采用高靜壓型臥式暗裝機(jī)組,為節(jié)省投資,減少噪聲源,采用一機(jī)多口的送風(fēng)方式,即通過機(jī)組出口處附加的多接頭靜壓箱,經(jīng)軟管與兩到三個(gè)出風(fēng)口相連接的送風(fēng)方式,暗裝在吊頂內(nèi),機(jī)組出口接送風(fēng)管,風(fēng)管底部設(shè)有兩到三個(gè)圓形散流器,新風(fēng)采用散流器平送。氣流組織設(shè)計(jì)的任務(wù)是合理地組織室內(nèi)空氣的流動(dòng),使室內(nèi)工作區(qū)空氣的溫度﹑相對(duì)濕度﹑速度和潔凈度能更好地滿足人們的舒適性要求。2.確定M點(diǎn):(44)式中:Q為空調(diào)房間總負(fù)荷,可得 =()/= kJ/kg 3.FP供冷量: 全冷量: =()= kW4.風(fēng)機(jī)盤管的選用:【5】 1 選用FP8型風(fēng)機(jī)盤管機(jī)組1臺(tái),高檔風(fēng)量880;機(jī)組的冷量是5850w,能滿足要求。如果計(jì)算所得的新風(fēng)量不足系統(tǒng)風(fēng)量的10%,則取系統(tǒng)送風(fēng)量的10%。Kg/s,則=[(18)]/[(18+2500) ]= g/kg=18+(2500+18)=()= Kg/s= 最小新風(fēng)量確定的原則:一個(gè)完善的空調(diào)系統(tǒng),除了滿足對(duì)環(huán)境的溫、濕度控制以外,還必須給環(huán)境提供足夠的新風(fēng)。① (41)② (42)③ (43)上式中的已知參數(shù)為Q、W、,未知參數(shù)為、。 風(fēng)機(jī)盤管加新風(fēng)系統(tǒng)的空氣處理風(fēng)機(jī)盤管加新風(fēng)系統(tǒng)的空氣處理方式有:1.新風(fēng)處理到室內(nèi)狀態(tài)的等焓線,不承擔(dān)室內(nèi)冷負(fù)荷;2.新風(fēng)處理到室內(nèi)狀態(tài)的等含濕量線,新風(fēng)機(jī)組承擔(dān)部分室內(nèi)冷負(fù)荷;3.新風(fēng)機(jī)組不僅承擔(dān)新風(fēng)冷負(fù)荷,還承擔(dān)部分室內(nèi)顯熱冷負(fù)荷和全部潛熱冷負(fù)荷,風(fēng)機(jī)盤管僅承擔(dān)一部分室內(nèi)顯熱冷負(fù)荷,可實(shí)現(xiàn)等濕冷卻,可改善室內(nèi)衛(wèi)生和防止水患;4.新風(fēng)處理到室內(nèi)狀態(tài)的等溫線,風(fēng)機(jī)盤管承擔(dān)的負(fù)荷很大,特別是濕負(fù)荷很大,造成衛(wèi)生問題和水患;5.新風(fēng)處理到室內(nèi)狀態(tài)的等焓線,并與室內(nèi)狀態(tài)點(diǎn)直接混合進(jìn)入風(fēng)機(jī)盤管處理。p);26℃時(shí),極輕勞動(dòng)成年男子的小時(shí)散熱量為109 g/(h人體散熱冷負(fù)荷時(shí)間08:0009:0010:0011:0012:0013:0014:0015:0016:0017:0018:00ClQ qs q1 g φ F(101) n5 5 5 5 5 5 5 5 5 5 5 Cls Cl1 合計(jì) Dτ 新風(fēng)冷負(fù)荷目前,我國(guó)空調(diào)設(shè)計(jì)中對(duì)新風(fēng)量的確定原則,仍采用現(xiàn)行規(guī)范、設(shè)計(jì)手冊(cè)中規(guī)定或推薦的原則, 根據(jù)房間用途具體確定。 以101房間為例,結(jié)果如下表。設(shè)備和用具的實(shí)際顯熱散熱量按下式計(jì)算1)辦公設(shè)備散熱量當(dāng)辦公設(shè)備的類型和數(shù)量無法確定時(shí),可按單位面積散熱指標(biāo)估算空調(diào)區(qū)的辦公設(shè)備散熱量,可按下式計(jì)算:CL′=FqS (37)式中: F——空調(diào)區(qū)面積 qS——辦公設(shè)備單位面積平均散熱指標(biāo),本設(shè)計(jì)中取11。必須指出::建筑地點(diǎn)在北緯27176。k) ; ——玻璃窗的冷負(fù)荷溫度逐時(shí)值,℃,在參考文獻(xiàn)[1]中附錄210中查得;——室內(nèi)設(shè)計(jì)溫度,℃ 。; K——玻璃的傳熱系數(shù),W /( m178。 圍護(hù)結(jié)構(gòu)瞬變傳熱形成冷負(fù)荷的計(jì)算方法 外墻和屋面瞬變傳熱引起的冷負(fù)荷在日射和室外氣溫綜合作用下,外墻和屋面瞬變傳熱引起的逐時(shí)冷負(fù)荷可按下式計(jì)算:【3】 (31)式中:——外墻和屋面瞬變傳熱引起的逐時(shí)冷負(fù)荷,W; A——外墻和屋面的面積,㎡;K——外墻和屋面的傳熱系數(shù),W/(㎡分散式:; ;、熱源。 各種空調(diào)系統(tǒng)的適用條件集中式 、多室熱濕負(fù)荷變化情況類似; ; 、濕度、潔凈度、噪聲、振動(dòng)等要求嚴(yán)格;;。,風(fēng)管短,各風(fēng)口風(fēng)量調(diào)節(jié)易達(dá)到均勻;小型機(jī)組余壓小,有時(shí)難以滿足風(fēng)管布置和必需的新風(fēng)量。,節(jié)能效果好,可根據(jù)各房間負(fù)荷情況自行調(diào)節(jié);無法實(shí)現(xiàn)全年多工況節(jié)能運(yùn)行調(diào)節(jié)。,便于管理和維修。 各空調(diào)系統(tǒng)方案比較空調(diào)系統(tǒng)按空氣處理設(shè)備的設(shè)置情況分類可分為集中系統(tǒng)、半集中系統(tǒng)、全分散系統(tǒng),其特征和應(yīng)用如下表:系統(tǒng)分類系統(tǒng)特征系統(tǒng)應(yīng)用集中系統(tǒng)集中進(jìn)行空氣的處理、輸送和分配單風(fēng)管系統(tǒng)、雙風(fēng)管系統(tǒng)、變風(fēng)量系統(tǒng)半集中系統(tǒng)除有集中的中央空調(diào)器外,在各自空調(diào)房間還分別有處理空氣的“末端裝置”末端再熱式系統(tǒng)、風(fēng)機(jī)盤管機(jī)組系統(tǒng)、誘導(dǎo)器系統(tǒng)全分散系統(tǒng)每個(gè)房間的空氣處理分別由各自的整體式空調(diào)器承擔(dān)單元式空調(diào)器系統(tǒng)、分體式空調(diào)器系統(tǒng) 集中式空調(diào)系統(tǒng)優(yōu)缺點(diǎn),機(jī)房面積較大,需要的層高較高。K等,具體取值見下表:【2】維護(hù)結(jié)構(gòu)名稱外墻外窗外門屋面?zhèn)鳠嵯禂?shù)K(W/ m2 空調(diào)相鄰房間溫差較小不考慮內(nèi)墻傳熱;室內(nèi)照明負(fù)荷按11W/m2計(jì)算;辦公室辦公設(shè)備類型和數(shù)量無法確定,故按單位面積散熱指標(biāo)計(jì)算辦公設(shè)備散熱量,一套辦公設(shè)備按主機(jī),顯示器,打印機(jī),傳真機(jī)各一臺(tái),并包括配套的辦公家具,根據(jù)教材表313確定中等強(qiáng)度辦公設(shè)備單位面積平均散熱指標(biāo)為11 w/m2; 辦公室按1人/10 m2。選用保溫層厚度為125mm的II型其K=北京市國(guó)際大廈空調(diào)設(shè)計(jì)說明書 建筑概況本設(shè)計(jì)為北京市國(guó)際大廈,是一個(gè)現(xiàn)代化寫字樓,地下一層,;地上四層,為辦公室;,為辦公室;,辦公室;,為辦公室;總建筑高度為15米。k。冷熱源資料:冷源:直燃型溴化鋰吸收式冷熱水機(jī)組生產(chǎn) 7℃的冷凍水; 熱源:直燃型溴化鋰吸收式冷熱水機(jī)組生產(chǎn)的熱水。K) 室內(nèi)設(shè)計(jì)參數(shù)[2]房間類型室溫(℃)相對(duì)濕度(%)噪聲聲級(jí)(dB(A))新風(fēng)量()辦公室26177。,布置困難,支風(fēng)管和風(fēng)口較多時(shí)不易均衡調(diào)節(jié)風(fēng)量。,使各房間空氣交叉污染;當(dāng)發(fā)生火災(zāi)時(shí)會(huì)通過風(fēng)管迅速蔓延。,維護(hù)管理不方便;水系統(tǒng)復(fù)雜,易漏水。,過渡季不能用全新風(fēng);大多用電加熱,耗能大;靈活性大,各空調(diào)房間可根據(jù)需要進(jìn)行調(diào)節(jié)。半集中式:、濕度控制要求一般的場(chǎng)合;
點(diǎn)擊復(fù)制文檔內(nèi)容
電大資料相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖片鄂ICP備17016276號(hào)-1