【正文】
ry Guide 2 BAGCHI, .: ‘A multilevel distributed microprocessor system for a nuclear power plant fire protection system controls, monitoring, and munication’, IEEE Trans., 1982 3 PUCILL, .: ‘Fire hazard protection, detection and monitoring systems’, , 2, Proceedings of Symposium on ADV in offshore and terminal measurement and control systems, Brighton, England, March 1979, 4 HEAVISID, L.: ‘Offshore fire and explosion detection and fixed fire’.Offshore Technological Conference, 12th Annual Proceedings,4, Houston, Texas, May 1980, 5 CELLENTANI,.,andHUMPHREY,.:‘Coordinated detection/munication approach to fire protection’, Specif: Eng., 6 ‘Motorola Microprocessors Data Manual’(Motorola Semiconductor Products, Austin, Texas, USA)7 Electronic Industries Association : ‘Interface between data terminal equipment and data munication equipment employing serial binary data interchange’(EIA Standard RS232, Washington, DC, 1969)8 MESAROVIC, ., MACKO, D., TAKAHARA, Y.: ‘Theory of hierarchical湖北理工學(xué)院 畢業(yè)設(shè)計(jì)(論文)外文文獻(xiàn)翻譯multilevel systems’(Academic Press, 1970)KASSEM, M.: ‘Fire alarm systems’, , Elec.amp。 ., Concordia University, Montreal, Canada, 1985 10 LIE, P., and KOTAMARTI, U.: ‘The design of a fire alarm system using microprocessors’, C481 Project, ., Concordia University, Montreal, Canada, 1986第四篇:【安全標(biāo)準(zhǔn)】消防安全檢查細(xì)則(超實(shí)用、超詳細(xì))【安全標(biāo)準(zhǔn)】消防安全檢查細(xì)則(超實(shí)用、超詳細(xì))20140731 防損培訓(xùn)網(wǎng)一、賣場(chǎng)(每日)檢查物品堆放是否整齊;與頂部噴淋、報(bào)警探測(cè)器、照明燈具高度是否保持一定水平間距(3050分)。易燃易爆化學(xué)危險(xiǎn)物品存放是否整齊;是否有良好的通風(fēng)環(huán)境。地面是否平整、無(wú)障礙物;是否清潔干凈、無(wú)水跡、無(wú)任何廢棄物、垃圾等。天面頂部懸掛物及繩索是否牢固、清潔;掛壁物是否固定。貨架受力后是否傾斜;物品堆放是否均勻。貨架上的緊固螺絲是否牢固;貨架、促銷臺(tái)四周是否光滑。貨架上照明燈是否有漏電保護(hù)開(kāi)關(guān)。滅火器、消火栓、防火門、安全通道前是否有物品堆放,影響其正常使用。噴淋末端放水閥是否漏水;壓力表是否正常(28kg)。防火卷簾門下是否有移動(dòng)貨架、貨品堆放,影響其正常升降。應(yīng)急照明燈是否正常;安全指示燈是否正常。賣場(chǎng)內(nèi)是否有人動(dòng)用明火;是否經(jīng)過(guò)審批;是否落實(shí)防火措施。1賣場(chǎng)內(nèi)是否有無(wú)人看管的梯子、補(bǔ)貨車、墊倉(cāng)板、液壓車等工具。1賣場(chǎng)內(nèi)是否有異常氣味及煙霧。1電加熱器使用是否經(jīng)過(guò)審批;是否有漏電保護(hù)開(kāi)關(guān)。1電器設(shè)備使用是否規(guī)范、是否有亂拉亂接電源線;試機(jī)臺(tái)、燈具展示柜等電源插座是否正常;電源插座是否固定在墻上、排列整齊。、倉(cāng)庫(kù)(每日)檢查物品堆放是否整齊;與頂部噴淋、報(bào)警探測(cè)器、照明燈具高度是否保持一定水平間距(3050公分);貨架頂部物品是否有防損包裝;是否超高()。物品堆放是否均勻;貨架受力后是否傾斜。物品堆放是否符合堆碼要求。禁示線內(nèi)是否有堆物。托盤是否完好;木檔是否有缺損。地面是否平整、無(wú)障礙物;是否清潔干凈、無(wú)水跡、無(wú)任何廢棄物、垃圾等。天面頂部懸掛物及繩索是否牢固、清潔;掛壁物是否固定;自行車的掛鉤是否安全。高空作業(yè)2米以上是否系好安全帶。滅火器、消火栓、防火門、安全通道、配電箱前是否有物品堆放,影響其正常使用。噴淋末端放水閥是否漏水;壓力表是否正常(28kg)。1是否有人動(dòng)用明火;是否經(jīng)過(guò)審批;是否落實(shí)防火措施。1是否有易燃易爆化學(xué)物品存放。1是否有異常氣味及煙霧。1電器設(shè)備使用是否規(guī)范;是否有亂拉亂接臨時(shí)電線;電源插座是否固定在墻上; 排列是否整齊。1應(yīng)急照明燈是否正常;安全指示燈是否正常。1電加熱器使用是否經(jīng)過(guò)審批;是否有漏電保護(hù)開(kāi)關(guān)。1肉類加工間鋸骨機(jī)是否有防護(hù)工具。1生鮮熟食加工間用氣、用電是否安全;排油煙機(jī)是否清潔;滅火器、石棉毯是否到位;報(bào)警探測(cè)器是否正常。1生鮮冷庫(kù)、加工間頂部是否堆放物品。冷庫(kù)是否有保暖衣服、防滑靴;進(jìn)出冷庫(kù)是否隨手關(guān)門、關(guān)燈。2烤鴨房用火、用氣是否安全;滅火器材是否到位;報(bào)警探測(cè)器是否正常。2面包房電器設(shè)備、烘箱、油炸爐、機(jī)械工具是否正常;工作時(shí)是否有專人看護(hù); 報(bào)警探測(cè)器是否正常;滅火器是否到位。2煤氣分路總閥門是否關(guān)閉。2消控系統(tǒng)、監(jiān)控系統(tǒng)、110報(bào)警系統(tǒng)、紅外報(bào)警系統(tǒng)、防盜報(bào)警系統(tǒng)運(yùn)行情況是 否正常。三、外圍;是否有缺損。三、關(guān)店后檢查內(nèi)容:(每日一次)檢查生鮮熟食加工間、各聯(lián)銷店動(dòng)力照明電源開(kāi)關(guān)、煤氣閥門、水龍頭、鼓風(fēng)機(jī)、排氣扇等設(shè)備是否關(guān)閉。貨架上日光燈是否關(guān)閉。各機(jī)房、配電間、辦公室是否有異常情況。地面、空間、垃圾房是否有不安全情況。是否有人加班。四、消防盲點(diǎn)(每日一次)檢查商場(chǎng)內(nèi)既無(wú)火災(zāi)報(bào)警系統(tǒng)探測(cè)器,又無(wú)噴淋裝置單間獨(dú)立的部位。檢查是否有異常情況。五、滅火器(每周一次)檢查滅火器存放位置是否正確。干粉滅火器壓力表是否正常(指針在綠色區(qū)域)。2kgCO2滅火器重量是否正常()。(,需充液)干粉要上下顛倒搖勻,使干粉不結(jié)塊。瓶體外觀是否生銹、清潔(油污、灰塵)。橡皮導(dǎo)管是否老化有裂縫。噴嘴是否損壞。保險(xiǎn)插銷是否正常。七、消火栓(每周一次)。、關(guān)。、水槍、小榔頭、緊急按鈕是否有缺損。八、化學(xué)危險(xiǎn)品(每周一次)1. 檢查易燃易爆物品周圍是否有熱源。2. 物品存放是否分類,且堆放整齊。3. 物品間存放是否有一定的間距。4. 是否有良好的通風(fēng)環(huán)境。5. 滅火器材是否到位、正常。九、防火門(每周一次)。、關(guān)。十、電加熱器(每周一次)。十一、火災(zāi)報(bào)警系統(tǒng)(每日一次),巡檢主機(jī)面板顯示、報(bào)警功能、打印功能、聯(lián)動(dòng)功能。,并通知工程部、供應(yīng)商處理。,防損部當(dāng)值員工全部知曉,并加強(qiáng)對(duì)故障區(qū)域的檢查十二、鏟車(每月一次)(補(bǔ)貨車、手推車)檢查操作者是否持證;行車時(shí)是否掛牌;思想是否集中。鑰匙保管是否妥當(dāng);是否有領(lǐng)用登記;是否當(dāng)天歸還。鏟車是否有保養(yǎng)記錄;手剎、腳剎、警示燈、喇叭是否正常。行進(jìn)時(shí)鏟子是否放近地面;作業(yè)時(shí)托盤下禁止人員經(jīng)過(guò);登高超2米是否系安全帶。鏟車充電是否在室外;充電區(qū)域是否通風(fēng);電源插座是否規(guī)范;周圍是否有可燃及易燃物品。鏟車是否停放在指定地點(diǎn);停放時(shí)是否拉緊制動(dòng)、檔次置零、鏟子放近地面、切斷電源、取下鑰匙。十三、消防水泵房(每月一次);電源指示燈是否亮;開(kāi)關(guān)位置是否在自動(dòng)狀態(tài)。、噴淋泵、穩(wěn)壓泵閥門開(kāi)關(guān)是否在正常工作狀態(tài)(常開(kāi)或常閉);電機(jī)啟動(dòng)、停止運(yùn)行是否正常;壓力表是否正常(28kg)。(常開(kāi)或常閉);壓力表是否正常(28kg);警鈴是否能報(bào)警。,消控中心是否有反饋信號(hào)。(28kg)。、消防結(jié)合器、噴淋結(jié)合器、室外消火栓周圍是否有物品堆放;閥門開(kāi)關(guān)是否正常;是否有漏水。十四、室內(nèi)、外消火栓出水檢測(cè)(每半年一次)、接口是否有漏水現(xiàn)象。(2kg以上)。;消控中心是否有反饋信號(hào)。十五、防火卷簾門檢測(cè)(每半年一次),防火卷簾門正常工作。、貨品堆放。(手動(dòng))。十六、火災(zāi)報(bào)警系統(tǒng)聯(lián)動(dòng)檢測(cè)(每半年一次)(消控系統(tǒng)處于手動(dòng)狀態(tài))(1)防排煙系統(tǒng):防排煙風(fēng)機(jī)動(dòng)作,排煙閥打開(kāi);(2)防火卷簾門動(dòng)作:主通道防火卷簾門二次降, 處延時(shí)30秒后全部下降,其它防火卷簾門一次全降;(3)正壓送風(fēng)系統(tǒng):正壓送風(fēng)機(jī)動(dòng)作(4)噴淋泵動(dòng)作;(5)消火栓泵動(dòng)作。(消控系統(tǒng)處于自動(dòng)狀態(tài))(1)賣場(chǎng)手報(bào)動(dòng)作或卷簾門兩側(cè)煙感、溫感報(bào)警后 a)警鈴報(bào)警; b)防火卷簾門下降,主通道二次降; c)排煙風(fēng)機(jī)啟動(dòng),排煙閥打開(kāi); d)送風(fēng)、空調(diào)停止運(yùn)行。(2)噴淋末端放水,壓力下降,消控中心水流指示器報(bào)警,消防泵房噴淋泵啟動(dòng);(3)啟動(dòng)室內(nèi)消火栓緊急按鈕,消防泵房消防泵啟動(dòng)動(dòng)作。各項(xiàng)檢測(cè)內(nèi)容需由供應(yīng)商、工程部、防損部共同參與,并由供應(yīng)商提供完整的檢測(cè)報(bào)告及對(duì)檢測(cè)存在問(wèn)題提出的改進(jìn)建議。所有消防外控設(shè)備在H機(jī)房?jī)?nèi)電控箱開(kāi)關(guān),應(yīng)全部處于自動(dòng)狀態(tài)。所有設(shè)備檢測(cè)要有檢測(cè)人員在現(xiàn)場(chǎng)查看設(shè)備運(yùn)行情況。本檢測(cè)要求適用于賣場(chǎng)每年6月、11月份消防聯(lián)動(dòng)檢測(cè),另每年11月份消防聯(lián)動(dòng)檢測(cè)還需對(duì)報(bào)警探測(cè)器等其它設(shè)備,進(jìn)行全面100%檢測(cè)、試驗(yàn)。十七、動(dòng)用明火檢查每次動(dòng)火地點(diǎn)、焊割材質(zhì)及周圍的環(huán)境要求相同,如若不同,要求施工單位重新申請(qǐng)。動(dòng)火證明需注明動(dòng)火時(shí)間,當(dāng)天12小時(shí)內(nèi)有效,逾期要求施工單位重新申請(qǐng)。動(dòng)火前及在動(dòng)火過(guò)程,防損部需對(duì)現(xiàn)場(chǎng)進(jìn)行檢查,確保安全。動(dòng)火申請(qǐng)人必須持有政府部門原件操作證,才能上崗操作。要求防損部員工熟記“十不燒”原則。(1)不是焊工,不能燒;(2)重點(diǎn)部門及重要場(chǎng)所未經(jīng)有關(guān)部門批準(zhǔn)和落實(shí)措施不能燒;(3)不了解焊、割地點(diǎn)及周圍情況不能燒;(4)不了解焊割件內(nèi)部是否安全不能燒;(5)盛過(guò)易燃易爆液體、氣體容器,未經(jīng)徹底清洗和排除危險(xiǎn)前不能燒;(6)用可燃材料作保護(hù)層,不能燒;(7)有壓力的容器管道不能燒;(8)焊割部位有易燃易爆物品,未清理或采取安全措施不能燒;(9)作業(yè)部位與外單位相接觸,在未弄清是否安全或已知有危險(xiǎn)而未采取措施的不能燒;(10)附近有與明火作業(yè)相抵觸的工種作業(yè),不能燒。第五篇:超詳細(xì)水電安裝工程交房標(biāo)準(zhǔn)超詳細(xì)水電安裝工程交房標(biāo)準(zhǔn),拿走不謝!筑龍施工|2015081819:56給排水工程基本要求:給水管道安裝牢固,橫平豎直,部件齊全,接口嚴(yán)密無(wú)滲漏;支架選型正確,安裝牢固,間距均勻;管道表面清潔無(wú)劃傷;功能性試驗(yàn)合格;管道標(biāo)識(shí)正確。排水管道安裝牢固,坡向正確,部件齊全,接口嚴(yán)密無(wú)滲漏,管道暢通、無(wú)堵塞;支架選型正確,安裝牢固,間距均勻;地漏選型正確,水封符合要求;管道表面清潔無(wú)劃傷;功能性試驗(yàn)合格;管道標(biāo)識(shí)正確。預(yù)埋套管標(biāo)高一致,管口圓滑,穿樓板套管冒出板面高度一致,防腐涂刷均勻。管道保溫封閉嚴(yán)實(shí),無(wú)縫隙、空隙,表面平整。噴淋管道布置合理,排列整齊,成行成線;部件齊全,接口嚴(yán)密無(wú)滲漏;支架選型正確,安裝牢固,間距均勻;管道表面清潔無(wú)劃傷;功能性試驗(yàn)合格;管道標(biāo)識(shí)正確設(shè)備安裝布置合理,排列整齊,固定牢固,標(biāo)高一致;運(yùn)行正常,安全可靠。管道及支架油漆涂刷均勻,無(wú)流墜、針孔、氣泡,色澤一致。器具安裝牢固,與墻地面接縫嚴(yán)密、平行;器具表面潔凈無(wú)污染、破損、滲漏;支托架固定牢固。電氣工程基本要求:戶內(nèi)強(qiáng)弱電箱安裝牢固,位置正確,部件齊全;箱體開(kāi)孔與導(dǎo)管管徑適配,箱蓋緊貼墻面表面無(wú)劃傷及碰傷。箱內(nèi)配線整齊,無(wú)絞接現(xiàn)象。墊圈下螺絲兩側(cè)壓的導(dǎo)線截面積相同,同一端子上導(dǎo)線連接不多于2根,防松墊圈等零件齊全,接地可靠。箱內(nèi)開(kāi)關(guān)動(dòng)作靈活可靠,箱內(nèi)接線整齊,回路編號(hào)齊全,標(biāo)識(shí)正確。預(yù)埋的燈頭盒、轉(zhuǎn)線盒蓋板安裝到位,標(biāo)高一致,標(biāo)示清晰;預(yù)埋的穿墻(梁)套管管口圓滑、管內(nèi)干凈、標(biāo)高一致,標(biāo)示清楚。衛(wèi)生間等電位聯(lián)結(jié)其金屬部件或零件,應(yīng)有專用接線螺栓與等電位聯(lián)結(jié)支線連接,且有標(biāo)識(shí),連接處螺帽緊固,防松零件齊全。插座、開(kāi)關(guān)安裝牢固、板面端正、排列整齊;四周無(wú)縫隙,表面光潔,無(wú)劃傷;導(dǎo)線分色、相序、接線正確。PE線在插座間不串聯(lián)。燈具安裝牢固、燈具及配件齊全,表面光潔,無(wú)損傷、變形、燈罩破損等缺陷;,燈具接地或接零可靠。橋架部件齊全、表面清潔,不變形,連接牢固,跨接準(zhǔn)確,接地可靠;支架設(shè)置合理、固定牢固;過(guò)墻、樓板處防火封堵嚴(yán)密,表面平整?!緛?lái)源】