【正文】
ic College BU Western Europe China September 2022 62 自動平衡閥 型? 防脫鋅 (DZR)銅合金閥體 , 英制標(biāo)準(zhǔn)螺紋接口。 ? 閥芯的筒體和彈簧由等級 300的不銹鋼制成。 彈簧 閥芯 測量點 關(guān)斷 (球閥 ) 接盤管的連接末端 JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 63 全 “ 自動 操作? 自動流量限制式平衡閥芯。 ? 平衡閥由工廠預(yù)設(shè), 避免在施工現(xiàn)場調(diào)整 。 JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 64 自動平衡閥自動限制流量JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 65 自動平衡閥自動限制流量JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 66 自動平衡閥自動限制流量JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 67 自動平衡閥自動限制流量JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 68 自動平衡閥自動限制流量JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 69 自動平衡閥自動限制流量JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 70 不同壓差下工作狀態(tài)壓差超過最大設(shè)計要求,閥芯筒體全收縮 與節(jié)流孔板的功能一致。 閥芯筒體根據(jù)壓差的變化調(diào)整開度精確保持設(shè)計流量在177。5%的范圍內(nèi)。 壓差低于最小設(shè)計要求,閥芯筒體全開 與節(jié)流孔板的功能一致。 JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 71 不同壓差下工作狀態(tài)? 如下所示例子,壓差范圍 14 – 210 kPaD Design Flow Pressure drop (kPaD) 14 (22) kPaD Range Minimum 210 kPaD Range Maximum Flow (L/s) Flow limiting zone Best to avoid operating above control range JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 72 ? 解決冷凍機分步啟動的問題 ? 在沒有自動平衡設(shè)備的條件下,即使每臺冷凍機都安裝一臺泵,流量也會因為冷凍機分步啟動而產(chǎn)生波動。 Chiller Condenser ON 10 L/s Cooling Towers 30L/s Chiller Condenser ON 10 L/s Chiller Condenser ON 10 L/s JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 73 ? 解決冷凍機分步啟動的問題 對并聯(lián)運行的定流量水泵,總流量由總的阻力決定 包括管道。 Head Pressure Total flow (l/s) System resistance curve 30 All units on 0 3 Combined pumps head curve 1 pump head curve 2 Combined pumps head curve 10 20 Operating point – all units running JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 74 ? 解決冷凍機分步啟動的問題 ? 在系統(tǒng)沒有自動平衡的條件下,當(dāng)部分設(shè)備關(guān)閉時,管道中流量減少,泵頭阻力減少,保持工作的泵加速運行產(chǎn)生過流。 Chiller Condenser ON 17 L/s Cooling Towers 17L/s Chiller Condenser OFF 0 L/s Chiller Condenser OFF 0 L/s JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 75 ? 解決冷凍機分步啟動的問題 ? 在沒有自動平衡設(shè)備的條件下,當(dāng)管道中的流量降低,泵頭的壓力將導(dǎo)致泵速度的增加和持續(xù)工作設(shè)備的過流。 Head Pressure Total flow (l/s) System resistance curve 30 All units on 0 3 Combined pumps head curve 1 pump head curve 2 Combined pumps head curve 10 Design 1 unit 17 Actual 1 unit Operating point 1 pump JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 76 解決冷凍機分步啟動的問題 在冷機后安裝平衡閥可以有效地解決問題 Chiller Condenser ON 10 L/s Cooling Towers 30L/s Chiller Condenser ON 10 L/s Chiller Condenser ON 10 L/s JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 77 ? 解決冷凍機分步啟動的問題 ? 當(dāng)泵的工作數(shù)量變化時,自動平衡閥將根據(jù)系統(tǒng)阻力的變化調(diào)整以保持設(shè)計流量 。 Head Pressure Total flow (l/s) System resistance curve 30 All units on 0 3 Combined pumps head curve 1 pump head curve 2 Combined pumps head curve 10 Design 1 unit Operating point 1 pump JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 78 ? 重要 : 檢查閥門的最小 和最大 作用壓差在閥門的調(diào)整范圍內(nèi) ! ? 最大 kPaD將在一臺泵工作的時候得到。 Head Pressure Total flow (l/s) System curve All 3 units on 30 All units on 0 10 1 unit on dPmax applied dPmin applied System curve 1 unit on dPmax valve Problematic selection JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 79 ? 自動平衡簡化系統(tǒng)設(shè)計 ? 自動平衡閥只需要裝在空氣處理機組,風(fēng)機盤管,冷機,冷凝器等處。 ? 不需要模塊設(shè)計 。 Cooling Tower Cooling Tower Chiller Chiller Primary pump Primary pump Secondary VSD pump/s Decoupling Bypass = 自動平衡閥 FCU amp。 AHU FCU amp。 AHU JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 80 水力循環(huán)系統(tǒng)的三個條件Let controllers control 使控制器發(fā)揮作用 Make your HVAC system satisfy the three hydronic conditions 確保暖通空調(diào)系統(tǒng)滿足三個水力工況條件 JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 81 ? 定流量系統(tǒng)與變流量系統(tǒng) ? 定流量系統(tǒng) – 定流量是指系統(tǒng)中不含任何動態(tài)閥門,主要用于末端設(shè)備無須通過流量來調(diào)節(jié)的系統(tǒng),如風(fēng)機盤官采用三速開關(guān),空調(diào)箱采用變風(fēng)量調(diào)節(jié)溫度的空調(diào)系統(tǒng)以及系統(tǒng)要求較低,只需補償器調(diào)節(jié)供暖水溫即可滿足需要的采暖系統(tǒng)。 – 定流量系統(tǒng)只存在靜態(tài)水力失調(diào),不存在動態(tài)水力失調(diào),因此只要在相關(guān)部位安裝靜態(tài)水力平衡閥即可。 – 通常在系統(tǒng)機房的 集水器 以及 關(guān)鍵的垂直、水平回水支管上 安裝靜態(tài)水力平衡閥。 水力系統(tǒng)平衡簡介JeanChristophe Carette, Hydronic College BU Western Europe China September 2022 82 ? 定流量系統(tǒng)與變流量系統(tǒng) ? 變流量系統(tǒng) – 變流量是指在系統(tǒng)運行過程中各分支環(huán)路的流量隨著外界環(huán)境負(fù)荷的變化而變化的。大部分時間系統(tǒng)流量是低于設(shè)計流量。 – 變流量系統(tǒng)一般即存在靜態(tài)水力失調(diào)也存在動態(tài)水調(diào),因些既要安裝靜態(tài)水力平衡閥,又要合理選擇動態(tài)水力平衡設(shè)備。 – 通常在系統(tǒng)機房的 集水器 以及 關(guān)鍵的垂直、水平回水支管上 安裝靜態(tài)水力平衡閥。 – 在需要 恒定流量的鍋爐及冷機管路 附近安裝固定式動態(tài)流量平衡閥。 – 在需可調(diào)式動態(tài)流量平衡時采用靜態(tài)閥與差壓閥結(jié)合,對流量進行調(diào)節(jié),主要 用于重要分支管理及需精確調(diào)節(jié)的空氣處理單元。 水力系統(tǒng)平衡簡介Jean