【正文】
177。2℃溫度變化率≤5℃/h 相對濕度:50%177。5%潔凈度:符合標(biāo)準(zhǔn)ASHRAE5276,粒度≥,個(gè)數(shù)≤10000粒/dm噪聲:關(guān)閉主設(shè)備的條件下,在工作人員正常辦公位置處測量不高68dB(A).(GB)機(jī)房單位面積的冷負(fù)荷為:257w/m2h系統(tǒng)控制室單位時(shí)間換氣數(shù):≥23次/h數(shù)據(jù)中心機(jī)房單位時(shí)間換氣數(shù):≥22次/h(2)防火防火系統(tǒng)基于以下原則建設(shè):采用高靈敏度火災(zāi)自動報(bào)警系統(tǒng);采用環(huán)保型FM200氣體滅火系統(tǒng);FM200氣體火火系統(tǒng)保護(hù)區(qū)及存儲環(huán)境溫度為0~54℃,存儲壓力25kg/cm2本氣體滅火系統(tǒng)能以自動、機(jī)械手動和遠(yuǎn)程啟動三種方式啟動;設(shè)有備用電源,操作時(shí)間為24小時(shí)。所有氣體滅火保護(hù)區(qū)的維護(hù)構(gòu)件滿足一定的抗壓要求。;;火災(zāi)發(fā)生時(shí),自動聲光報(bào)警,警示相應(yīng)區(qū)域人員撤離。防火動作原理:當(dāng)防護(hù)區(qū)火災(zāi)發(fā)生,感煙探測器報(bào)警時(shí):火災(zāi)自動報(bào)警系統(tǒng)報(bào)警,閃燈、警鈴動作,提示工作人員撤離火災(zāi)發(fā)生區(qū)域;當(dāng)感煙探測器報(bào)警和感溫探測器同時(shí)報(bào)警時(shí):火災(zāi)自動報(bào)警系統(tǒng)報(bào)警,防護(hù)區(qū)外閃燈、蜂鳴器動作,控制聯(lián)動系統(tǒng)切除非消防電源、關(guān)閉相應(yīng)區(qū)域防火閥等聯(lián)動設(shè)備,同時(shí)啟動紅外探測系統(tǒng);當(dāng)紅外探測系統(tǒng)確認(rèn)相應(yīng)保護(hù)區(qū)無人員存在時(shí),啟動氣體滅火系統(tǒng)進(jìn)行滅火。(3)地板抬升系統(tǒng)阻燃性:60REI抗靜電性:105109隔 音:大于32DB集中承受力 20007000N地板抬升高度 ≥350mm分散承受力 1500035000N/ m2施工標(biāo)準(zhǔn)為:國家標(biāo)準(zhǔn)《計(jì)算機(jī)機(jī)房用活動地板技術(shù)條件》(GB665086)布線系統(tǒng)在每個(gè)機(jī)架上提供結(jié)構(gòu)化布線槽,為每個(gè)機(jī)架提供局域接入服務(wù)。機(jī)架布線槽有兩種規(guī)格:16端口或8端口。綜合布線系統(tǒng)采用下走線方式布線。偉伯?dāng)?shù)據(jù)中心綜合布線系統(tǒng)建設(shè)采用的標(biāo)準(zhǔn)如下:中華人民共和國建筑物結(jié)構(gòu)化布線標(biāo)準(zhǔn):建筑與建筑群結(jié)構(gòu)化布線系統(tǒng)工程設(shè)計(jì)規(guī)范修訂本(CECS 72:97)中華人民共和國建筑物結(jié)構(gòu)化布線標(biāo)準(zhǔn):建筑與建筑群結(jié)構(gòu)化布線系統(tǒng)工程施工及驗(yàn)收規(guī)范修訂本(CECS 89:97)中華人民共和國行業(yè)標(biāo)準(zhǔn):城市住宅區(qū)和辦公樓電話通信設(shè)施設(shè)計(jì)標(biāo)準(zhǔn)(YD/T200893)中華人民共和國通信行業(yè)標(biāo)準(zhǔn):總配線架技術(shù)要求和試驗(yàn)方法(YD/T69493)中華人民共和國通信行業(yè)標(biāo)準(zhǔn):通信設(shè)計(jì)安裝抗震設(shè)計(jì)暫行規(guī)定(YD200392)中華人民共和國郵電部部標(biāo)準(zhǔn):市內(nèi)通信全塑電纜線路工程設(shè)計(jì)規(guī)范(YDJ990)中華人民共和國郵電部部標(biāo)準(zhǔn):電信網(wǎng)光纖數(shù)字傳輸系統(tǒng)工程施工及驗(yàn)收暫行技術(shù)規(guī)定(YDJ4489)中華人民共和國郵電部部標(biāo)準(zhǔn):市內(nèi)電話程控交換設(shè)備安裝工程施工及驗(yàn)收暫行技術(shù)規(guī)定(YDJ5088)中華人民共和國郵電部部標(biāo)準(zhǔn):市內(nèi)電話線路工程施工及驗(yàn)收技術(shù)規(guī)范(試行)(YDJ3885)ISO/IEC 11801國際商用建筑物布線標(biāo)準(zhǔn)EIA/TIA 568商用建筑物電信布線標(biāo)準(zhǔn)EIA/TIA 569電信通路和空間商用建筑標(biāo)準(zhǔn)EIA/TIA 570住宅和輕工業(yè)建筑布線標(biāo)準(zhǔn)IEEE 、IEEE 、IEEE 、IEEE 歐洲標(biāo)準(zhǔn) EN 5016EN 5016EN 50169具體施工指標(biāo)遵循如下相關(guān)國家標(biāo)準(zhǔn):《計(jì)算站場地技術(shù)要求》(GB288789)《電子計(jì)算機(jī)機(jī)房工程施工及驗(yàn)收規(guī)范》(SJ/T3000393)《建筑裝飾工程施工及驗(yàn)收規(guī)范》(JGJ7391)《電子計(jì)算機(jī)機(jī)房設(shè)計(jì)規(guī)范》GB5017493《火災(zāi)自動報(bào)警系統(tǒng)設(shè)計(jì)規(guī)范》GB5011698《建筑物防雷設(shè)計(jì)規(guī)范》GB5005794《低壓配電設(shè)計(jì)規(guī)范》GB5005495《計(jì)算站場地安全要求》GB9361《處理保密信息的電磁屏蔽室的技術(shù)要求和測試方法》BMB31999《通訊機(jī)房靜電防護(hù)通則》YD/T75495《環(huán)境電磁衛(wèi)生標(biāo)準(zhǔn)》GB917588《電磁輻射防護(hù)規(guī)定》GB870288(1)強(qiáng)電系統(tǒng)采用雙路強(qiáng)電引入,每個(gè)機(jī)架都通過配電柜引出單獨(dú)的供電線路到機(jī)架,每個(gè)機(jī)架可用電源功率≥5KVA。(2)UPS系統(tǒng)機(jī)房UPS系統(tǒng)和備用柴油發(fā)電機(jī)系統(tǒng)共同提供IDC冗余電源。UPS 系統(tǒng)的建設(shè)容量為斷電后滿足以下系統(tǒng)用電1530分鐘。機(jī)房設(shè)備用電;應(yīng)急照明;門禁系統(tǒng)用電;空調(diào)用電;消防系統(tǒng)用電。(3)備用柴油發(fā)電機(jī)系統(tǒng)柴油發(fā)電機(jī)系統(tǒng)設(shè)計(jì)為N+1冗余備份系統(tǒng),額定功率N≥IDC 各系統(tǒng)功率之和。設(shè)計(jì)儲油滿足油機(jī)系統(tǒng)運(yùn)行時(shí)間≥8小時(shí)。外文資料Network cablingsolutionNow,information industry is booming,information has bee a key strategic resource,puter technology in people39。s lives have been playing an in creaingly important thegradual popularization ofthe network,network constructionisthe development ofinformation technologyenterprises tothe inevitable choice, corporate networkis a verylarge and plexsystem, It not onlymodern development, integratedinformation management andoffice automationapplicationsand a series ofbasicoperating platform, but also providea variety ofapplication servicesto make the informationtimelyand accurately transmitted to the varioussystems. in Richcondition,make ahigh level and plete puternetwork. Typically, Structured Cabling System can run for 10 to 15 order to adapt to Requirements of System Changes, Must fully considerthe mostconvenient way, the minimuminvestmentfor system expansion andmaintenance. After running Structured Cabling System, so thatoncethe entirenetworkafter routing, in 10 to15 yearsto meetthe development needs ofenterprise networks, establishment of amodern management,means of municationin puter networks,meet to shareresources,improve operational capability andefficiency. During this timedo not need toexpand it, Will not increaseinvestment, Does not destroy the Structural layout and change the way of zhe wire,the ability what adapt to diversification is powerful, conducive tolongterm using and expanding, meet thetechnological advances and The economic isreasonable At structured Cabling system use advancedwiringmaterials to lay the way,it is UTP, transfer ratethanin the100M, fully able to meet10 to 15years of developmentneeds. Structured Cabling System hat adoptUTPtwisted pairas the transmissionmedium,by StarParkstructure,so that all ways of information is General. Access toall equipment, alteration, orremovaldid not change thewiring system, Justchangethe appropriatenetwork equipmentand the necessaryjumpersto connect. Structured Cabling System used highquality materialsand binationscrimp way that Constitute a set ofhigh standards ofinformation channel uses a dedicated instrument calibration ineattenuation, crosstalk,signal to noise ratio,To ensure theelectricalcapacity,and thus will not cause crossinterference information. In addition,the structure ofthe physicalcharacteristics ofthe startopology, Makesaline faultshall not affectanyother linesof operation, At the same timeas thecircuitoperation, maintenance andfault detection and maintenance ofa convenient,in order to protectthe reliable operation ofthe systemfor a long time.中文翻譯:網(wǎng)絡(luò)布線方案在當(dāng)今信息產(chǎn)業(yè)蓬勃發(fā)展的今天,信息已經(jīng)成為一種關(guān)鍵性的戰(zhàn)略資源,計(jì)算機(jī)技術(shù)在人們的生活中已經(jīng)起到了越來越重要的作用。隨著網(wǎng)絡(luò)的逐步普及,企業(yè)網(wǎng)絡(luò)的建設(shè)是企業(yè)向信息化發(fā)展的必然選擇,企業(yè)網(wǎng)絡(luò)是一個(gè)非常龐大而復(fù)雜的系統(tǒng),它不僅為現(xiàn)代化發(fā)展、綜合信息管理和辦公自動化等一系列應(yīng)用提供基本操作平臺,而且能提供多種應(yīng)用服務(wù),使信息能及時(shí)、準(zhǔn)確地傳送給各個(gè)系統(tǒng)。 在一定的資金資源下,建立一個(gè)高水平、完善的計(jì)算機(jī)網(wǎng)絡(luò)。通常情況下,綜合布線系統(tǒng)的使用壽命為10~15年。為了適應(yīng)系統(tǒng)變化的要求,必須充分考慮以最簡便的方法、最低的投資,實(shí)現(xiàn)系統(tǒng)的擴(kuò)展和維護(hù)。 采用綜合布線后,使到整個(gè)網(wǎng)絡(luò)系統(tǒng)一次布線后在10~15年內(nèi)能滿足企業(yè)網(wǎng)絡(luò)的發(fā)展需求,建立一個(gè)具有現(xiàn)代化管理、通信手段的計(jì)算機(jī)網(wǎng)絡(luò),滿足共享資源、提高業(yè)務(wù)能力和工作效率。在這段時(shí)間內(nèi)可不必進(jìn)行擴(kuò)建,不會增加投資,也不破壞建筑物內(nèi)現(xiàn)在的結(jié)構(gòu)布局和改變布線方式,適應(yīng)變化能力強(qiáng),有利于長期的使用和今后的擴(kuò)展,符合技術(shù)上的先進(jìn)和經(jīng)濟(jì)上的合理。在綜合布線系統(tǒng)中采用先進(jìn)的材料進(jìn)行布線——超五類UTP,傳輸?shù)乃俾试?00M以上,完全能夠滿足10~15年的發(fā)展需要。 綜合布線系統(tǒng)采超五類UTP雙絞線作為傳輸介質(zhì),物理上采用星型樸結(jié)構(gòu),因此所有的信息通道全部可以通用。所有設(shè)備的接入,改動,或者移除均不改變布線系統(tǒng),只需增減相應(yīng)的網(wǎng)絡(luò)設(shè)備以及必要的跳線來連接即可。 綜合布線采用高品質(zhì)的材料和組合壓接的方式構(gòu)成一套高標(biāo)準(zhǔn)的信息通道。每條通道都采用專用的儀器校核線路衰減、串音、信噪比,以保證電氣的能力,因而不會造成信息的交叉干擾。另外物理拓樸星形結(jié)構(gòu)的特點(diǎn),使得任何一條線路故障均不影響其他線路的運(yùn)行,同時(shí)為線路的運(yùn)行維護(hù)及故障檢測及維修提供了方便,從而保障了系統(tǒng)長時(shí)間的可靠運(yùn)行。THANKS !!!致力為企業(yè)和個(gè)人提供合同協(xié)議,策劃案計(jì)劃書,學(xué)習(xí)課件等等打造全網(wǎng)一站式需求歡迎您的下載,資料僅供參考可修改編輯