freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

基站空調(diào)維修手冊(cè)-資料下載頁(yè)

2024-11-02 08:12本頁(yè)面

【導(dǎo)讀】一.基礎(chǔ)理論··································································3. ····························································3. ····················································3. ································································3. ····································································3. ····································································4. ····································································4. ··········································&

  

【正文】 332)RN5 機(jī)型出現(xiàn) E1 告警所有問(wèn)題全部列出: 氟利昂多引起高壓保護(hù)器動(dòng)作(斷開)。 該機(jī)使用的時(shí)間過(guò)長(zhǎng),制冷系統(tǒng)內(nèi)部有泄漏處理完后常加冷劑或更換過(guò)壓縮機(jī)不注意, 臟物入進(jìn)制冷系統(tǒng)引起毛細(xì)管堵塞不能達(dá)到節(jié)流、降溫、降壓作用。倒至空調(diào)器高壓壓力過(guò) 高、低壓壓力過(guò)低,壓力保護(hù)器動(dòng)作(斷開)。 室外風(fēng)機(jī)壞(注:風(fēng)機(jī)啟動(dòng)電容壞,風(fēng)機(jī)也是不動(dòng)轉(zhuǎn)),不轉(zhuǎn),倒至保護(hù)器動(dòng)作(斷開)。 室外機(jī)相序電流保護(hù)電路板壞 室外機(jī)凝器積太多塵土、太臟倒至空調(diào)過(guò)熱保護(hù) 故障檢測(cè)排除: 經(jīng)過(guò)檢測(cè),空調(diào)器制冷時(shí)用壓力表測(cè)量低壓壓力過(guò)高為 Mpa( ~ Mpa),停機(jī)后 平衡壓力為 (表示系統(tǒng)里氟利昂不多不少)。該機(jī)使用的時(shí)間只有一年,并且沒(méi)有更 換過(guò)壓縮機(jī),空調(diào)器制冷時(shí)用壓力表測(cè)量低壓壓力為 Mpa 不是負(fù)壓狀態(tài),可以排除毛 細(xì)管堵塞的可能??照{(diào)器制冷時(shí)直觀室內(nèi)風(fēng)機(jī)和室外風(fēng)機(jī)都正常運(yùn)行,可以排除風(fēng)機(jī)壞的可 能。如果是室外機(jī)相序電流保護(hù)電路板壞,空調(diào)器室內(nèi)機(jī)運(yùn)行 3 到 5 分鐘后,室內(nèi)機(jī)電腦 板輸送信號(hào)給室外機(jī)相序電流保護(hù)電路板時(shí)就馬上出現(xiàn) E1 告警,空調(diào)器是不能夠制冷的。 由此可見,只有室外機(jī)凝器積太多塵土、太臟倒至空調(diào)過(guò)熱保護(hù)出現(xiàn) E1 告警。 處理過(guò)程: 清洗干凈空調(diào)室外機(jī)冷凝器,試機(jī)正常,故障處理完畢! 注: 發(fā)現(xiàn) E1 告警,又不是室外機(jī)過(guò)臟過(guò)熱保護(hù)時(shí),最大的可能原因是室外機(jī)相序電流 保護(hù)電路板壞,在沒(méi)有配件更換的情況下,我們可以臨時(shí)跳開不用。方法:打開室內(nèi)機(jī)底下 面蓋,在打開室內(nèi)機(jī)風(fēng)機(jī)頂上的鐵皮蓋就可以看到室內(nèi)機(jī)電腦板上有一根黃色電源線(標(biāo)有 OVC 字母,這 根線就是保護(hù)線),找一根電源線從室內(nèi)機(jī)零線接好引到這根黃色線上(在電 腦板上不能取肖它,照常接好,只是多引一根零線和它串連),連接好后空調(diào)就能夠制冷正 常,如果還是不能夠制冷說(shuō)明室外機(jī)保護(hù)繼電器壞。 注: 到了基站我們發(fā)現(xiàn)格力室內(nèi)和室外機(jī)都運(yùn)行正常,又是在制冷模試狀態(tài)下,空調(diào)不 能制冷時(shí),原因是空調(diào)器三相錯(cuò)相,更換好相序即可制冷 。 案例 3: 故障現(xiàn)象: 格力 KF72LW(72332)RN5 整機(jī)無(wú)顯示 問(wèn)題 : 室內(nèi)機(jī)變壓器燒壞 故障分析 : 基站格力空調(diào)室內(nèi)機(jī)是由交流市電 220 伏供給, 220 伏經(jīng)過(guò)壓敏電阻和保險(xiǎn)絲在到變壓器初 級(jí)變壓后次級(jí)為 AC12~ 14V 左右輸出供給室內(nèi)電腦板使用。由此我們可以分析為: 外部電路出現(xiàn)問(wèn)題(如空調(diào)電源空開有問(wèn)題或電源線斷路)。 變壓器燒壞或室內(nèi)機(jī)電腦板上的保險(xiǎn)、壓敏電阻( ZNR)燒壞。 室內(nèi)機(jī)電腦板上的穩(wěn)壓元件 7812 或 7805 損壞。 23 空調(diào)維修實(shí)用手冊(cè) 操作板故障(如接線松動(dòng)或按鍵損壞) 故障檢測(cè)排除: 按 “開/關(guān)鍵 ”開機(jī),整機(jī)無(wú)反應(yīng)。打開室內(nèi)機(jī)接線盒,檢查接線端子已有市電 220177。10% 電壓輸入。再檢查室內(nèi)機(jī)電腦板上的保險(xiǎn)絲和壓敏電阻均良好,再測(cè)量檢查變壓器的初級(jí)有 AC220V,次級(jí)沒(méi)有有 AC12~ 14V 左右輸出,正明變壓器已燒壞。 處理過(guò)程: 更換上好的變壓器,試機(jī)正常。 案例 4: 故障現(xiàn)象: 格力 KF72LW(72332)RN5 室內(nèi)機(jī)工作正常,室外機(jī)風(fēng)扇運(yùn)轉(zhuǎn),壓縮不運(yùn)轉(zhuǎn)。 問(wèn)題 : 室外機(jī)三相保護(hù)器壞 故障分析 : 室內(nèi)機(jī)工作正常,室外機(jī)風(fēng)扇也運(yùn)轉(zhuǎn)(說(shuō)明室內(nèi)機(jī)沒(méi)有故障,已有信號(hào)輸送到室外機(jī)) 室外機(jī)故障:一、壓縮機(jī)壞。二、市區(qū)電缺相。三、壓縮機(jī)交流接觸器壞。四、三相保 護(hù)器壞。 故障檢測(cè)排除: 室內(nèi)機(jī)工作正常,室外機(jī)風(fēng)扇也運(yùn)轉(zhuǎn)(說(shuō)明室內(nèi)機(jī)沒(méi)有故障),打開室外機(jī)則蓋發(fā)現(xiàn)壓縮機(jī) 不工作。測(cè)量市電已有 380V 電壓到室外機(jī),在測(cè)量三相保護(hù)器上的接線觸點(diǎn)發(fā)現(xiàn)( A 點(diǎn)與 零線測(cè)量有 220V,但是 C 點(diǎn)與零線測(cè)量沒(méi)有 220V,正明三相保護(hù)器已壞) 處理過(guò)程: 更換上好的三相保護(hù)器,試機(jī)正常。 海爾三菱空調(diào) 案例 5: 故障現(xiàn)象: 海爾三菱重工 3 匹機(jī),室外機(jī)空調(diào)連接銅管被盜,重新焊接好連接管,抽真空加氟利昂,開 機(jī)前 3 分鐘后,室內(nèi)機(jī)和室外機(jī)運(yùn)行正常,每次重新開機(jī)都只能正常制冷 5 到 10 分種后左 右就不能制冷。 問(wèn)題 : 空調(diào)制冷系統(tǒng)冰堵 故障分析: 查三相供電電壓是否正常,三相接線端子是否都接穩(wěn)接撈。因?yàn)榭照{(diào)壓縮機(jī)啟動(dòng)時(shí)電流 比較大,如果電壓不穩(wěn)定,接線接觸不良,電流會(huì)不斷慢慢增大,倒至電流保護(hù)或壓縮 機(jī)熱保護(hù)。 室內(nèi)和室外機(jī)通信是否正常。海爾三菱重工重新開機(jī)后 3 到 5 分鐘,從室內(nèi)機(jī)電腦板輸 送信號(hào)給室外機(jī),室外機(jī)才能夠得到信號(hào)正常運(yùn)行。 空調(diào)分為兩大系統(tǒng)(控制電器系統(tǒng)和制冷系統(tǒng))??照{(diào)器的高、低壓保護(hù)器是否動(dòng)作, 充加氟利昂時(shí)是否加多或加少。 故障檢測(cè)排除: 經(jīng)測(cè)量三相供電電壓都很正常( 380V177。10%),三相接線端子接線也很撈固。由此可以排 除電壓不穩(wěn)定問(wèn)題。 開機(jī) 3 分鐘后,室內(nèi)室外機(jī)運(yùn)行正常,能夠正常制冷 5 到 10 分種才不能制冷。由此可 見,可以排除內(nèi)外機(jī)通信信號(hào)異常的可能。 24 空調(diào)維修實(shí)用手冊(cè) 制冷幾分鐘后,空調(diào)壓力保護(hù)器動(dòng)作(斷開)。在空調(diào)還能夠正常運(yùn)行時(shí),用壓力表 量空調(diào)壓力:高壓壓力特別高,低壓壓力在從正常制冷時(shí)的 ,運(yùn)行幾分鐘后緩慢變 小,最后到負(fù)壓,空調(diào)保護(hù)器動(dòng)作停機(jī),停機(jī) 15 到 20 分鐘后平衡壓力逐步慢慢回升至 左右(表示氟利昂充加不多不少)。經(jīng)過(guò)逐步分析到這,就可以找到故障的原因:由于該機(jī) 室外銅管被盜,壓縮機(jī)吸入大量潮濕空氣或大量水份,致使制冷系統(tǒng)里積存了大量的水分, 當(dāng)焊接好連接銅管抽真空充注好氟利昂后,空調(diào)機(jī)制冷工作時(shí),水分和氟利昂混合在一起, 經(jīng)過(guò)壓縮機(jī)高壓排氣到毛細(xì)管:節(jié)流、降溫、降壓后,水份結(jié)成冰,堵塞毛細(xì)管,使空調(diào)器 制冷系統(tǒng)不能夠組成制冷巡環(huán)的過(guò)程。本機(jī)工作情況明顯是冰堵。 處理過(guò)程: 放掉制冷系統(tǒng)中的氟利昂,在高壓管截流毛細(xì)管前端加焊一個(gè)能夠扭開放出硅膠的干燥 硅膠過(guò)濾器,重新抽真空加冷劑。其后第一次開機(jī)運(yùn)行 15 分鐘左右收氟關(guān)機(jī),打開干燥硅 膠過(guò)濾器,把里面由原來(lái)的藍(lán)色硅膠變成變白色硅膠放出來(lái),重新在加入硅膠,扭好,排空 氣在運(yùn)行,第二次運(yùn)行 30 分種左右,在放出變?yōu)榘咨墓枘z。以此操作 3 到 4 次左右,直 到放進(jìn)去的硅膠在也不會(huì)變面白色(表明制冷系統(tǒng)里面已不在有水份)。收好氟后,即可將 過(guò)濾器拆除,重新焊接好銅管,排室內(nèi)機(jī)管道里的空氣,試機(jī) 30 分鐘制冷正常。故障處理 完畢! 力博特空調(diào) 案例 6: 故障現(xiàn)象: 力博特空調(diào)室內(nèi)室外機(jī)運(yùn)行正常,但不能制冷,停機(jī)重新開機(jī)后有時(shí)又能制冷一下,到現(xiàn)場(chǎng) 用手摸室外機(jī)儲(chǔ)液灌感覺(jué)很燙手。 問(wèn)題 : 室外機(jī)平衡閥壞,有時(shí)串氣引起制冷系統(tǒng)流向錯(cuò),制冷系統(tǒng)不經(jīng)過(guò)室內(nèi)機(jī)蒸發(fā)器循環(huán),倒至 不能夠達(dá)到制冷系統(tǒng) 4 大件循環(huán)的目的。 故障分析 : 室內(nèi)室外機(jī)啟動(dòng)正常,但不制冷,由此可以考慮到空調(diào)器電器部分沒(méi)有問(wèn)題,只有檢測(cè)制冷 系統(tǒng)部分: 氟利昂多或少。 熱力膨脹閥壞,不能達(dá)到節(jié)流、降溫、降壓作用。 電磁閥壞或室外機(jī)冷凝器灰塵積多過(guò)臟 ,引起室外機(jī)保護(hù)繼電器動(dòng)作(斷開)。 室外機(jī)平衡閥壞 , 引起制冷系統(tǒng)流向錯(cuò) 故障檢測(cè)排除: 經(jīng)過(guò)檢測(cè),用壓力表測(cè)量制冷系統(tǒng)停機(jī)平衡壓力為 (表示系統(tǒng)里氟利昂不多不 少),檢查室外機(jī)保護(hù)繼電器是否動(dòng)作(斷開)都為正常(表示電磁閥正常,室外機(jī)冷凝器 沒(méi)有因灰塵積多過(guò)臟),當(dāng)時(shí)以為是電壓相序錯(cuò),調(diào)相 序后一樣不能夠制冷 ,最后用手摸儲(chǔ)液 灌感覺(jué)很燙手,正常時(shí)儲(chǔ)液器不是燙手反而有點(diǎn)冰涼,由此可以斷定是室外機(jī)平衡閥串氣, 冷劑經(jīng)過(guò)壓縮機(jī)吸收壓縮后排出的高溫高壓氣體冷劑流向冷凝后直接循環(huán)回儲(chǔ)液灌到壓縮 機(jī),冷劑沒(méi)有循環(huán)到室內(nèi)機(jī)蒸發(fā)器和熱力膨脹,所以達(dá)不到空調(diào) 4 大件制冷系統(tǒng)循環(huán)的目的。 處理過(guò)程: 將系統(tǒng)內(nèi)冷劑全部放空,焊出平衡閥不用,不會(huì)影響制冷效果(此閥的主要作用是保證 流經(jīng)冷凝器內(nèi)的冷媒量保持穩(wěn)定,其實(shí)現(xiàn)在的定頻壓縮機(jī)在額定工況下輸出冷媒量是比較穩(wěn) 定,所以此閥可以不用),重新連接焊好制冷系統(tǒng)回路,抽空加氟利昂,開機(jī)制冷正常。故 障處理完畢! 25 空調(diào)維修實(shí)用手冊(cè) 案例 7: 故障現(xiàn)象: 力博特空調(diào)整機(jī)不工作,操作面板無(wú)反應(yīng)。 問(wèn)題 : 變壓器燒壞 故障分析 : 在這我就不針對(duì)變壓器單一問(wèn)題來(lái)分析,把力博特空調(diào)( 2 板本和 3 板本)從室內(nèi)到室外機(jī) 整個(gè)電器控制系統(tǒng)一一分析: 外部電路出現(xiàn)問(wèn)題(如空調(diào)電源空開有問(wèn)題或電源線斷路)。 (室內(nèi)機(jī)部分)變壓器燒壞。 (室內(nèi)機(jī)部分)變壓器次級(jí)輸出端保護(hù)開關(guān)動(dòng)作(斷開) (室內(nèi)機(jī)部分)電源接口板燒壞 (室內(nèi)機(jī)部分)風(fēng)機(jī)繼電器燒壞 (室外機(jī)部分)保護(hù)繼電器動(dòng)作 (室外機(jī)部分)交流接觸燒壞 故障檢測(cè)排除: 力博特空調(diào)通常接線: 380 伏電壓從空氣開關(guān)直接接到室外機(jī)交流接觸器輸放端(注: 也有少部分力博特空調(diào)是 220V 的,從空開接 220V 電壓到力博特空調(diào)室外機(jī)交流接觸器輸 入端的,該機(jī)為 220V 壓縮機(jī)),室內(nèi)機(jī)另從空開供給 220V 電壓。整機(jī)不工作,操作面板無(wú) 反應(yīng): 測(cè)量是否有市電或缺相斷路,正常。 測(cè)量變壓器初級(jí)有 220V 交流輸入,次級(jí) 是否有交流 AC24V 左右輸出,有表示變壓器完好,無(wú) AC24V 輸出表示變壓器燒壞。 變 壓器次級(jí)輸出端保護(hù)開關(guān)是否動(dòng)作,如動(dòng)作,重新按回去即可(它的作用是:電壓電流過(guò)大 時(shí),動(dòng)作斷開保護(hù)后面的電路斷開)。 變壓器次級(jí)有 24V 左右電壓輸出,正級(jí)接入電源 接口板,另一根(白色)接機(jī)殼。測(cè)量風(fēng)機(jī)繼電器線圈(面對(duì)機(jī)子,風(fēng)機(jī)繼電器最低部那兩 根) 1 口和 3 口有 AC24V 左右電壓和測(cè)量室內(nèi)機(jī)連到室外機(jī)的接線端子 3 號(hào)線(棕、 紅、橙)端子, 1 號(hào)和 2 號(hào)線或 1 號(hào)和 3 號(hào)線有 24V 左右交流電輸出(表示電源接口板已有 信號(hào)輸出,電源接口板無(wú)故障)。 測(cè)量風(fēng)機(jī)繼電器線圈 1 口和 3 口有 AC24V 左右電壓, 再測(cè)量面對(duì)風(fēng)機(jī)繼電器最左上角的端子和 220V 零線是否有 220V 電壓,有表示這個(gè)繼電器 完好,無(wú)表示繼電器壞室內(nèi)風(fēng)機(jī)不運(yùn)轉(zhuǎn)。 室外機(jī)保護(hù)繼電器到目前還沒(méi)有發(fā)現(xiàn)壞過(guò),它 的作用是:制冷系統(tǒng)壓力過(guò)高保護(hù),電壓電流過(guò)大保護(hù)。正常制冷時(shí),它是由室內(nèi)機(jī)接線端 子 號(hào)線(棕、紅)輸入 24V 電壓,再由這個(gè)保護(hù)繼電器來(lái)控制室外機(jī)的交流接觸器 線圈。有時(shí)發(fā)現(xiàn)空調(diào)器能制冷幾分鐘后,室外機(jī)不運(yùn)轉(zhuǎn),就是這個(gè)保護(hù)繼電器動(dòng)作,這時(shí)測(cè) 量不是 1 號(hào)和 2 號(hào)線(棕、紅)有 24V 電壓,反是 1 號(hào)和 3 號(hào)線(棕、 3 號(hào)橙色是保護(hù)線) 有 24V 電壓。 1 號(hào)和 3 號(hào)線有 24V 電壓,表示制冷系統(tǒng)壓力過(guò)高保護(hù),可能的原因有:室 外風(fēng)機(jī)不運(yùn)轉(zhuǎn),氟利昂多,室外機(jī)冷凝器過(guò)臟,電磁閥不吸合。 室外交流接觸器是控制 壓縮機(jī)和室外風(fēng)機(jī)供電啟動(dòng)的重要元器件,交流接觸燒壞,室外機(jī)整機(jī)不工作。測(cè)量方法: 只 要交流接觸器線圈有 AC24V 電壓,交流接觸又能吸合正常(表示交流接觸器完好 ),測(cè) 量線圈有 AC24V 電壓,但交流接觸又不能吸合(表示交流接觸器線圈已燒壞,已不能在使 用)。 處理過(guò)程: 測(cè)量有交流市電 220V 電壓到空調(diào)室內(nèi)機(jī)。再測(cè)量變壓器初級(jí)有 220V 交流輸入,測(cè)量變壓 器次級(jí)無(wú)交流 24V 輸出(表示變壓器燒壞),更換新的變壓器,開機(jī)制冷正常。故障處理完 畢! 案例 8: 26 空調(diào)維修實(shí)用手冊(cè) 故障現(xiàn)象: 力博特空調(diào)高溫告警 ,室內(nèi)機(jī)運(yùn)行正常 . 室外機(jī)不能工作 問(wèn)題 : 室外機(jī)三相交流接觸器壞,導(dǎo)致室外機(jī)不能工作 故障分析 : 力博特空調(diào)高溫告警 ,室內(nèi)機(jī)運(yùn)行正常,室內(nèi)機(jī)運(yùn)行正常,室外機(jī)不能工作。有制冷式 COOL. 但不能制冷。 可能原因有: 1:內(nèi)機(jī)接口板壞,沒(méi)有 24V 電壓送給外機(jī)保護(hù)繼電器 2:保護(hù)繼電器壞,沒(méi)有 24V 電壓送給室外機(jī)三相交流接觸器壞 3:室外機(jī)三相交流接觸器壞,室外風(fēng)扇電機(jī)和壓縮機(jī)沒(méi)得到市區(qū)電。 故障檢測(cè)排除: 用萬(wàn)用表來(lái)測(cè)量,室外機(jī)三相交流接觸器線圈已獲有交流 24V 電壓(表明內(nèi)機(jī)接口板和外 機(jī)保護(hù)繼電器是完好的),交流接觸器線圈已獲有交流 24V 電壓但外機(jī)三相交流接觸器伋不 吸合。斷電用電阻檔量三相交流接觸器線圈無(wú)窮大。這時(shí)證明三相交流接觸器線圈已燒壞, 更換三相交流接觸器,試機(jī)正常。 處理過(guò)程: 更換三相交流接觸器,試機(jī)正常。 案例 9: 故障現(xiàn)象: 力博特空調(diào)啟動(dòng)運(yùn)行后空氣開關(guān)跳閘的現(xiàn)象。 故障分析: 空調(diào)電源部分有對(duì)地或配件短路。 處理辦法: 首先關(guān)電,再用萬(wàn)用表(歐姆擋)開始從空調(diào)電源線路開始檢查或選擇性的排查。 其次檢查看線路有沒(méi)有短路或?qū)Φ亍?照{(diào)線路短路主要是注意線和線之間有沒(méi)有短路或空調(diào) 配件燒壞造成內(nèi)部短路,線路短路主要是電路板和一些保險(xiǎn)裝置損壞;空調(diào)線路對(duì)地主要檢 查火線是否有直接對(duì)地的或配件燒壞后導(dǎo)致對(duì)地的,線路對(duì)地主要是火線和壓縮機(jī)、內(nèi)外風(fēng) 機(jī)繞阻損壞對(duì)地。 檢查出故障點(diǎn)后,整改線路或更換損壞配件,最后開機(jī)試機(jī)查看是否恢復(fù)。 案例 10: 故障現(xiàn)象: 力博特空調(diào)控制面板按鍵失靈現(xiàn)象。 可能有的故障: 空調(diào)控制面板壞或低壓電壓異常。 處理辦法: 首先檢測(cè)電源部分的低壓部分供電是否正常(主要是空調(diào)內(nèi)機(jī)變壓器 的好壞),變壓器使用 24V。檢測(cè)辦法是用萬(wàn)用表( 200 毆)檢測(cè),線圈的阻值(初級(jí)是 13 左右毆、次級(jí) 6 毆這樣 左右),超出范圍或無(wú)限的可判斷已壞。也可以帶電測(cè)量,用萬(wàn)用表電壓檔檢測(cè)查看有沒(méi)有 24V 輸出,有 24V 輸出表示正常,如超出范圍表示已損壞。 其次空調(diào)低壓部分正常,就可能是電路板壞,主要是檢電路板的保險(xiǎn)部分是否完好和輸出給 控制面板的直流 5V( N5 和 T 口電壓)否正常來(lái)判斷。 檢查出故障點(diǎn)后,更換損壞的控制面板配件,最后開機(jī)試機(jī)查看是否恢復(fù)。 案例 11: 27 空調(diào)維修實(shí)用手冊(cè) 故障現(xiàn)象: 力博特空調(diào)內(nèi)機(jī)正常運(yùn)行外機(jī)不工作。 可能有的故障: 電路板故障。 元件故障。 系統(tǒng)故障。 處理辦法: 電路故障。 外機(jī)到電的啟動(dòng)過(guò)程。 (市電 380V 外機(jī)同時(shí)引 220V 到內(nèi)機(jī),內(nèi)機(jī)的 220V 通過(guò)變壓器后輸出 24V 交流低壓給 電路板檢測(cè),檢測(cè)后的 24V 提供給外機(jī)的交流接觸器工作,交流接觸器工作后外機(jī)啟動(dòng)運(yùn) 行) 根據(jù)啟動(dòng)過(guò)程一路排查元件和線路的好壞排查。 首先檢測(cè)市電是否正常(線電壓 380V 左右,相電壓 220V 左右),在市電正常情況下停 電用萬(wàn)用表歐姆檔檢測(cè)空調(diào)電路,先檢測(cè)電源部分的低壓部分供電是否正常(主要是空調(diào)內(nèi) 機(jī)變壓器的好壞),變壓器使用 24V。檢測(cè)辦法是用萬(wàn)用表( 200 毆)檢測(cè),線圈的阻值(初 級(jí)是 13 左右毆、次級(jí) 6 毆這樣左右),超出范圍或無(wú)限的可判斷已壞。也可以帶電測(cè)量,用 萬(wàn)用表電壓檔檢測(cè)查看有沒(méi)有 24V 輸出,有 24V 輸出表示正常,如超出范圍表示已損壞。 變壓器輸出 24V 通過(guò)室內(nèi)電路板檢測(cè)后,傳到外機(jī)交流接觸器,如無(wú)輸出就可能是電路板 壞,電路板檢測(cè)主要是檢電路板的保險(xiǎn)部分是否完好和輸出給控制面板的直流 5V( N5 和 T 口電壓)否正常來(lái)判斷。有 24V 到外機(jī)后還有檢測(cè)交流接觸器好壞(交流接觸器主要檢查 線圈電阻是否在 6 毆左右和觸電的好壞)才檢測(cè)完線路和元件。 系統(tǒng)故障。 (系統(tǒng)壓力過(guò)低或過(guò)高,低壓保護(hù)開關(guān)和高壓保護(hù)開關(guān)動(dòng)作保護(hù)空調(diào),外機(jī)不啟動(dòng)或啟 動(dòng)平凡) 檢測(cè)辦法首先用壓力表檢測(cè)系統(tǒng)靜壓壓力,正常的靜壓在九到十公斤左右,如果低于表 示壓力過(guò)低,需充加制冷劑,如過(guò)高排出制冷劑。 案例 12: 故障現(xiàn)象: 力博特制冷效果差,內(nèi)外機(jī)都正常,重啟后能短時(shí)能制冷。 可能存在問(wèn)題: 平衡閥故障。 膨脹閥問(wèn)題。 處理辦法 : 平衡閥主要平衡壓力的,損壞后制冷劑不通過(guò)蒸發(fā)器循環(huán),空調(diào)不能制冷,需更換平衡 閥。 膨脹閥在系統(tǒng)中主要是節(jié)流降壓作用,膨脹閥壞系統(tǒng)可能出現(xiàn)堵塞,出現(xiàn)系統(tǒng)壓力參數(shù) 改變,制冷效果差或不制冷。出現(xiàn)的現(xiàn)象有膨脹閥前后的溫差很大或系統(tǒng)高低壓壓力高壓偏 高低壓偏低。修復(fù)需要更換膨脹閥。 三洋空調(diào) 案例 13: 故障現(xiàn)象: 三洋 SPWV253DHL5 機(jī)型,按 “開/關(guān)鍵 ”開機(jī),整機(jī)無(wú)反應(yīng),燈不亮。 故障分析 : 28 空調(diào)維修實(shí)用手冊(cè) 外部電路出現(xiàn)問(wèn)題(如空調(diào)電源空開有問(wèn)題或電源線斷路)。 變壓器燒壞或室內(nèi)機(jī)電腦板上的保險(xiǎn)、壓敏電阻( ZNR)燒壞。 室內(nèi)機(jī)電腦板上的穩(wěn)壓元件 7812 或 7805 損壞。 操作板故障(如接線松動(dòng)或按鍵損壞) 故障檢測(cè)排除: 按 “開/關(guān)鍵 ”開機(jī),整機(jī)無(wú)反應(yīng)。檢查接線端子空氣開關(guān)是有市電 380V177。10%電壓輸入。 有,再檢查室
點(diǎn)擊復(fù)制文檔內(nèi)容
公司管理相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1