freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

冬季雞舍通風(fēng)ppt課件-資料下載頁

2025-01-12 10:33本頁面
  

【正文】 ! 理論 /計(jì)算的數(shù)值只能作參考 ? The right minimum rate is critical for bird performance and to minimise heat consumption 正確的最小通風(fēng)量是雞群生產(chǎn)性能和最小保溫成本的關(guān)鍵 ? Under ventilation – bird performance is promised 通風(fēng)不足 – 雞群生產(chǎn)性能受影響 ? Over ventilation – excessive heat consumption, dry house, possible drafts on birds 通風(fēng)量過大 – 加熱成本高,雞舍干燥,可能造成賊風(fēng) ? Evaluate your minimum ventilation setting every day 每天評估最小通風(fēng)量的設(shè)定 ? Minimum ventilation fans should operate on a cycle timer 最小通風(fēng)風(fēng)機(jī)應(yīng)該由定時鐘控制 Example of Minimum Ventilation Rate 最小通風(fēng)量舉例 Example Calculation 計(jì)算舉例 Assume: 假設(shè) ? Bird weight = 800g 。 10 000 birds 體重 =800克, 10000只雞 ? Ventilation “factor” = 0,594m179。/hr/kg 通風(fēng)系數(shù) = 0,594m179。/hr/kg Calculation: 計(jì)算 ? Ventilation = 10 000 x 0,594m179。/hr/bird = 5 940m179。/hr Cycle Timer Setting: 定時鐘設(shè)定 ? 5 minute cycle 。 1 x fan @ 20 000m179。/hr (example) 5分鐘循環(huán) Time ON = (5 940 x 5) 247。 (1 x 20 000) = 1,6 minutes Time ON = 1 min 36 sec Time OFF = 3 min 24 sec Note: This is an example on how to perform the calculation, and does not necessarily suggest that the “Ventilation Factor” used above is the only way to calculate minimum ventilation Evaluating Minimum Ventilation 最小通風(fēng)評估 ? The only way is by visiting the house 只有一種方式:進(jìn)雞舍 ? Done preferably first thing each morning 每天早上的第一件事 ? Evaluate in the first 3060 seconds: 剛進(jìn)入雞舍 3060秒時評估 – Bird fort, spread, activity 雞群的舒適度,分布,活動 – “ Stuffiness” “ 悶” – Humidity level 濕度 – Ammonia 氨氣 – Condensation/sweating (walls, drinker pipes, steel) 冷凝水 – “ AIR QUALITY” “ 空氣質(zhì)量” – What you feel in first 3060 seconds is what the chicken lived with all night 進(jìn)雞舍后前 3060秒的感覺就是雞群整晚所處的環(huán)境 ? “Purging” the house in the morning is unacceptable 早晨大量通風(fēng)不可取 (Purging – running many fans to clear the air) Evaluating Minimum Ventilation 評估最小通風(fēng) Always ask yourself: 經(jīng)常問自己: ? Is the air quality and house conditions acceptable? 空氣質(zhì)量和雞舍條件是否可接受? – If not, then you need to increase the minimum rate 如果不能接受,增加最小通風(fēng)量 ? Is it too fresh? 空氣是否太好? – If so, then you could be ventilating more than you need to 如果是,則通風(fēng)量太多 – This will use more heat 這將浪費(fèi)熱量 – Could cause cold drafts on the chicks 可能造成賊風(fēng) Remember! 切記! ? House sealing is critical and non negotiable 雞舍密閉最關(guān)鍵,沒有商量的余地 ? Minimum ventilation (cycle timer) determines how much fresh air you bring into the house (air quality) 最小通風(fēng)量(定時鐘設(shè)定)決定了有多少新鮮空氣進(jìn)入雞舍(空氣質(zhì)量) ? Pressure is used to make the air go where you want it to when it enters the house 負(fù)壓是控制進(jìn)入雞舍的新鮮空氣以何種方式進(jìn)入 Summary 總結(jié) ? Seal the house as tight as possible 盡可能密閉雞舍 ? Make sure there is more than enough heating capacity, and evenly distributed 加熱能力要足夠,分布均勻 ? Choose minimum/side wall inlets very carefully 小心挑選最小進(jìn)風(fēng)口 ? Make sure there are enough inlets for transitional ventilation 確保有足夠數(shù)量的進(jìn)風(fēng)口以滿足過渡通風(fēng)的需要 ? Install side wall inlets correctly 正確安裝進(jìn)風(fēng)口 ? Ensure inlets are correctly set up and managed 確保正確設(shè)定與管理進(jìn)風(fēng)口 ? Inlets MUST operate based on negative pressure 進(jìn)風(fēng)口必須通過負(fù)壓操作 ? Operate minimum fans on a cycle timer 最小通風(fēng)風(fēng)機(jī)由定時鐘控制運(yùn)轉(zhuǎn) ? Manage the cycle timer for good air quality 管理好定時鐘設(shè)定,確??諝赓|(zhì)量 THANK YOU 謝謝
點(diǎn)擊復(fù)制文檔內(nèi)容
教學(xué)課件相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1