【文章內(nèi)容簡介】
................................................................................ 65 接地的種類 .............................................................................................................. 65 保護接地裝置的確定 .............................................................................................. 65 人工接地裝置的確定 .............................................................................................. 66 單根垂直接地體的接地電阻的確定 ...................................................................... 66 接地體根數(shù)的確定 .................................................................................................. 66 第十一章 箱變電氣五防保護 .................................................................................... 67 電氣 “ 五防 ” 內(nèi)容 ................................................................................................... 67 實現(xiàn) “ 五防 ” 的途徑 .............................................................................................. 67 第十二章 變電站的平面布置 及交流原理圖 ....................................................... 67 箱式變電站總體布置 ............................................................................................. 67 變電站一次系統(tǒng)圖 見附頁 圖 001 .......................................................................... 68 35KV 側箱體的平面布置圖見附頁 圖 002 ........................................................... 68 10KV 側箱體的平面布置圖見附頁 圖 003 ........................................................... 68 電容箱箱體的平面布置圖見附頁 圖 004 ............................................................ 68 變電站的整體平面布置圖見附頁 圖 005.............................................................. 68 五防鎖程序圖見附頁 圖 006 .................................................................................... 68 各柜交流原理 圖見附頁 圖 007011 ...................................................................... 68 第十三章 結論 ................................................................................................................. 68 參考文獻 ............................................................................................................................. 69 摘 要 本課題的主要內(nèi)容包括箱式變電站的發(fā)展應用,箱式變電站的結構分類,箱式變電站一次系統(tǒng)設計及其設備選型,二次系統(tǒng)設計,以及箱式變電站的智能監(jiān)控系統(tǒng)。 本次設計中進行了電氣主接線的設計、短路電流計算、主要電氣設備選擇及校驗(包括斷路器、隔離開關、電流互感器、電壓互感器、母線等)、各電壓等級配電裝置設計、各器件繼電保護和整定設計以及防雷保護的配置。35kV 箱式變電站的設計高壓側額定電壓為 35kV,低壓側額定電壓為 10kV,主變壓器容量為5000kVA。 35kV 側母線采用單母線, 10kV 側母線采用單母線分段接線方式 。 關鍵詞 : 箱變;結構;一次系統(tǒng);二次系統(tǒng) Design of 35 kV agricultural boxtype transformer substation Abstract The article regard boxtype transformer substation as a development for relating boxtype transformer substation applied, the construction of boxtype transformer substation divides into sesection, emphasizing the treatise boxtype transformer substation a the very equipments in design in subsystem chooses the type, two subsystems design, and the intelligence of boxtype transformer substation supervises and control the system. There is also a design for main electrical connection in this engineering, the calculation for shortcircuit electric current,the selection of electrical device and calibration (including circuit breaker, isolator, current transformer, potential transformer ,bus bar etc.) and the design for distribution installation per. voltage grade, direct current system and lightning protection is also design high pressure side sum of boxtype transformer substation settles electric voltage as 35 kV, the lowpressure side sum settles electric voltage as 10 kV, main transformer capacity is 5000 lord connects the single mother in adoption in line line cent segment connects the voltage of 35 kV sectionalized single bus bar scheme, electric voltage of 10 kV sectionalized single and transfer bus bar. Keywords : boxtype transformer substation。construction。 first system。second system 第一章 緒論 引言 隨著市場經(jīng)濟的發(fā)展,國家在城鄉(xiāng)電網(wǎng)建設和改造中,要求高壓直接進入負荷中心,形成高壓受電 —變壓器降壓 —低壓配電的供電格局,所以供配電要向節(jié) 地、節(jié)電、緊湊型、小型化、無人值守的方向發(fā)展,箱式變電站 (簡稱箱變 )正是具有這些特點的最佳產(chǎn)品,因而在城鄉(xiāng)電網(wǎng)中得到廣泛應用。其次隨著社會發(fā)展和城市化進程的加快,負荷密度越來越高,城市用地越來越緊張,城市配電網(wǎng)逐步由架空向電纜過渡,架桿方式安裝的配電變壓器越來越不適應人們的要求。因此,預裝式變電站成為主要的配電設備之一。與此同時,由于信息化、網(wǎng)絡化和智能化住宅小區(qū)發(fā)展,因此不僅要求箱變安全可靠,同時要求具有 “ 四遙 ” (遙測、遙 信 、遙調(diào)、遙控 )的智能化功能。這種智能箱式變電站 (簡稱智能箱變 )環(huán)網(wǎng)供電時,在特定自 主軟件配合下,能完成故障區(qū)段自動定位、故障切除、負荷轉帶、網(wǎng)絡重構等功能,從而保證在一分鐘左右恢復送電 [1]。 箱式變電站的類型 箱式變電站有美式箱式變電站和歐式箱式變電站。美式預裝式變電站在我國叫做“ 預裝式變電站 ” 或 “ 美式箱變 ” ,它將變壓器器身、高壓負荷開關、熔斷器及高低連線置于一個共同的封閉油箱內(nèi),構成一體式布置。用變壓器油作為帶電部分相間及對地的絕緣介質(zhì)。同時,安裝有齊全的運行檢視儀器儀表,如壓力計,壓力釋放閥,油位計,油溫表等。歐式預裝式變電站以前在我國習慣稱為 “ 組合式變電站 ” ,它是將高壓開 關設備、配電變壓器和低 壓配電裝置布置在三個不同的隔室內(nèi),通過電纜或母線來實現(xiàn)電氣連接 , 我的設計主要是采用組合變電站 設計 。 箱式變電站的結構 歐式預裝式變電站的總體結構包括三個主要部分:高壓開關柜、變壓器及低壓配套裝置,其總體結構主要有兩種形式:一種為組合式;另一種為一體式。組合式布置是高壓開關設備、變壓器和低壓配電裝置三部分個為一室,即由高壓室、變壓器室和低壓室三個隔室組成,可按 “ 目字型 ” 或 “ 品字型 ” 布置,如圖 11 所示。 “ 目字型 ” 布置與“ 品字型 ” 布置相比, “ 目字型 ” 接線較為方便,故大多采用 “ 目字 型 ” 布置。但 “ 品字型 ” 布置結構較為緊湊,特別是當變壓器室排布多臺變壓器時, “ 品字型 ” 布置較為有利 [2]。 (a)目字型布置 (b)品字型布置 圖 11 歐式預裝式變電站的整體布置形式 HV高壓室; LV低壓室; TM變壓器室; ZL操作走廊 箱式變電站的技術特點 箱式變電站的高壓室一般是由高壓負荷開關、高壓熔斷器和避雷器等組成的,可以進行停送電操作并且有過負荷和短路保護。低 壓室由低壓空氣開關、電流互感器、電流表、電壓表等組成的。為了可靠實現(xiàn)五防要求,各電器元件之間采用了機械聯(lián)鎖,各電器元件都安裝在有足夠強度和剛度的結構上,以便于導線的連接。另外箱變還都具有電能檢測、顯示、計量的功能,并能實現(xiàn)相應的保護功能,還設有專用的接地導件,并有明顯的接地標志。此外為適應戶外工作環(huán)境,箱式變電站的殼頂一般都采用隔層結構,內(nèi)裝有隔熱材料,箱體底部和各室之間都有冷卻進出風口,采用自然風冷和自動控制的 HV TM LV TM HV LV ZL LV TM LV HV HV LV TM TM TM LV LV HV HV 強迫風冷等多種形式,以保證電氣設備的正常散熱,具有防雨、防塵、防止小動物進入等措施。 箱式變電站 有如下特點: ① 技術先進安全可靠 箱體部分采用目前國內(nèi)領先技術及工藝,可保證在- 40℃ ~+ 40℃ 的惡劣環(huán)境下正常運行。箱體內(nèi)一次設備采用單元真空開關柜、干式互感器、真空斷路器 (彈簧操作機構 )等國內(nèi)技術領先設備,安全性高,二次采用微機綜合自動化系統(tǒng),可實現(xiàn)無人值守。 ② 自動化程度高 全站智能化設計,可實現(xiàn) “ 四遙 ” ,即遙測、遙信、遙控、遙調(diào),每個單元均具有獨立運行功能,繼電保護功能齊全,可對運行參數(shù)進行遠方設置,對箱體內(nèi)濕度、溫度進行控制,滿足無人值班的要求 [3]。 ③ 工廠預制化。 ④ 組合方式靈活。 ⑤ 投資省、 見效快。 ⑥ 占地面積小。 設計任務 變電站設計原始數(shù)據(jù):本變電站位于縣城邊緣,公路交通方便; 35kV 單回路進線,進線長度 l=25km;導線型號 LGJ150,均為三類負荷,生活用電和農(nóng)