freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

蘇州市隆鑫大廈通風(fēng)及空調(diào)工程設(shè)計(jì)說明書(留存版)

2025-08-11 12:31上一頁面

下一頁面
  

【正文】 n in the face this summer as the hot weather, Changsha will not exceed the current peak power systems and electricity was cut off. 2 HVAC field ways and means of energy conservation Science and technology advances, so HVAC emerging field of new technologies, a number of ways we can achieve energy saving HVAC systems. HVAC system is designed so that the economic situation in the efficient running HVAC system, particularly the central air conditioning system is a large and plex systems, system design will directly affect the system performance. Such systems are often designed by the maximum load, while the actual operation is basically the part load operation, if the system part of the design can not meet the requirements of part load operation, then the system39。出入頻率較低的住宅建筑,按5次換氣次數(shù)。 第八章 消聲、減震與保溫設(shè)計(jì)(1) 在進(jìn)行風(fēng)管和水管的布置計(jì)算時(shí),要結(jié)合聲音學(xué)的測(cè)量方法,對(duì)室內(nèi)的噪聲進(jìn)行控制,必要時(shí)需要進(jìn)行消聲器的安裝;(2) 在水泵間和制冷機(jī)房的布置時(shí),宜考慮周圍房間對(duì)隔振和消聲是否有較嚴(yán)格的要求,對(duì)機(jī)房里面設(shè)備的控制,要把消聲減震放在首位,吸聲就是其次;(3) 在考慮通風(fēng)機(jī)和空調(diào)系統(tǒng)的噪音時(shí),最好采用然衰減,當(dāng)自然衰減不能達(dá)到效果時(shí),要在系統(tǒng)管路上加消聲器。平衡閥也能同時(shí)進(jìn)行流量測(cè)定、流量調(diào)節(jié)、關(guān)斷和排污。5=,選用同樣兩臺(tái)冷卻塔與制冷機(jī)組相對(duì)應(yīng),這樣可以在負(fù)荷校時(shí)暫停一臺(tái),以達(dá)到節(jié)能的目的,選擇南京大洋的兩臺(tái)冷卻塔,其性能參數(shù)如下:型號(hào)冷卻水量m3/h主要尺寸風(fēng)機(jī)直徑mm風(fēng)量m3/h電機(jī)功率kW進(jìn)水壓力104Pa總高度mm最大直徑mmHYB11011035002120120012003水泵的揚(yáng)程利用下列公式計(jì)算: (7—5)式中:——水管道的總阻力,Pa; ——冷凝設(shè)備阻力,Pa; ——水泵軸線與冷卻塔布水器噴水口高度差, mH2O; ——冷卻塔噴嘴噴霧壓力,mH2O,約等于7 mH2O。在進(jìn)行空調(diào)設(shè)計(jì)的前期要充分考慮設(shè)計(jì)方案的可行性,考慮選用不同方案的經(jīng)濟(jì)性和可靠性。(2) 設(shè)定個(gè)管段的假定流速,一般空調(diào)主風(fēng)道風(fēng)速為5~,支風(fēng)管為3~ m/s。(3) 對(duì)于對(duì)空調(diào)風(fēng)速及空調(diào)溫度有嚴(yán)格要求的房間,送風(fēng)氣流要沿著頂棚徑向流動(dòng),以貼附的方式形成射流。對(duì)于五、六層,分成主樓區(qū)和、副樓區(qū),主樓區(qū)用兩個(gè)新風(fēng)機(jī)組,副樓區(qū)用一個(gè)新風(fēng)機(jī),七、八、九、十層各自用兩個(gè)新風(fēng)機(jī)組。℃),=℃,=26℃;=()=根據(jù)已定=,=,=,=,=174 ,=,==照明負(fù)荷采用指標(biāo)法,參考《實(shí)用供熱空調(diào)設(shè)計(jì)手冊(cè)》,查得客房的照明指標(biāo)是Cz=15W/㎡。劃分標(biāo)準(zhǔn):176。這種方式能保證新風(fēng)的新鮮度,控制也比較靈活。對(duì)風(fēng)機(jī)盤管加新風(fēng)系統(tǒng)使用的建筑樓層共十層,為了節(jié)約空間,每層的新風(fēng)機(jī)組采用吊頂?shù)姆绞剑瑔坞娫垂╇姷姆块g,和風(fēng)機(jī)盤管一起滿足室內(nèi)的熱量和水分的要求。3. 當(dāng)空調(diào)房間個(gè)數(shù)較多、房間內(nèi)人員的數(shù)量不集中時(shí),同時(shí)建筑樓層較低,各房間的使用獨(dú)立,選用獨(dú)立的風(fēng)機(jī)盤管和獨(dú)立新鮮空氣系統(tǒng)。 設(shè)計(jì)依據(jù) 設(shè)計(jì)任務(wù)書建筑圍護(hù)結(jié)構(gòu):外墻:按照《實(shí)用供熱空調(diào)設(shè)計(jì)手冊(cè)》、240墻、保溫材料為水泥膨脹珍珠巖的I范例,=注:滯留人數(shù)多及人員稠密的地方,采用變速風(fēng)機(jī)節(jié)能效果較明顯。,有以下四種系統(tǒng)可供選擇:全空氣式空調(diào)系統(tǒng)、空氣—水式空調(diào)系統(tǒng)、全水式空調(diào)系統(tǒng)、冷劑式空調(diào)系統(tǒng)。用以下兩種方式為房間送新風(fēng):(1) 新風(fēng)機(jī)獨(dú)立調(diào)節(jié),可隨室外氣象變化進(jìn)行調(diào)節(jié),保證室內(nèi)濕度與新風(fēng)量的要求。按下式計(jì)算:39。 (311)式中: ——單位時(shí)間內(nèi)成人的散濕量,;——房間內(nèi)的人數(shù);——群集系數(shù),由附錄;——成人單位時(shí)間散熱量, 房間最小新風(fēng)量人員密度辦公室 30m179。本工程五層至十層采用風(fēng)機(jī)盤管+獨(dú)立新風(fēng)的空調(diào)系統(tǒng),新風(fēng)單獨(dú)送入房間,由于是賓館是標(biāo)準(zhǔn)間一般都采用吊頂?shù)男问?,所以五到七層風(fēng)盤采用臥式暗裝,通過百葉風(fēng)口側(cè)送入房間內(nèi),八到十層采用散流器下送。寫字間的樓層衛(wèi)生間排風(fēng)同樣是次計(jì)算方法得到,排風(fēng)由各換氣扇的排風(fēng)管集中到排風(fēng)豎井,通過排風(fēng)豎井將排氣扇排出的氣體排至室外。(2)標(biāo)出管段的流量,然后進(jìn)行標(biāo)號(hào)。 水系統(tǒng)總的沿程阻力和局部阻力損失為 設(shè)備阻力損失為3 mH2O則= 3mH2O=故選ISG型管道離心泵,型號(hào)為80100A(I)離心泵三臺(tái),其中兩用一備,該冷凍水泵的主要技術(shù)參數(shù)為: 冷凍水泵型號(hào)型號(hào)流量Q總揚(yáng)程轉(zhuǎn)速電動(dòng)機(jī)功泵效率葉輪直徑重量H(m)Kw%D mmKgL/h r/min    80100A(I)891029004748087進(jìn)行水泵的配管布置時(shí),應(yīng)注意以下幾點(diǎn):(1)考慮水泵的震動(dòng)問題,在安裝基座上加橡膠墊,接管位置連接冷水柔性軟管,可以延長(zhǎng)機(jī)組使用年限。水系統(tǒng)的立管最高點(diǎn)處很容易聚集管路中的氣體,所以在立管的最高點(diǎn)處應(yīng)該設(shè)置自動(dòng)排氣閥,同時(shí)在接管上應(yīng)設(shè)置閘閥。(4)當(dāng)設(shè)備間的走廊長(zhǎng)度超過20米的時(shí)候,制冷機(jī)房要配有兩個(gè)門,兩個(gè)門的間距要盡可能的離得遠(yuǎn),最少要有一個(gè)門的開門方向要向外。 (3)不需要保溫的金屬管道可以采用仿佛措施,可以刷防銹漆。因?yàn)閷痈叽笥?m,所以就按3m高度計(jì)算;地下停車場(chǎng)按全面通風(fēng)考慮,按最大的防煙分區(qū)來計(jì)算排煙量,規(guī)范中規(guī)定每個(gè)防煙分區(qū)最大面積為500㎡,每平米的排煙量按120m179。之外,各個(gè)防火分區(qū)的排煙、排風(fēng)、送風(fēng)系統(tǒng)宜單獨(dú)設(shè)置,若排煙風(fēng)道穿越防火分區(qū),則需要在管道兩端加防火隔斷閥,應(yīng)按置進(jìn)風(fēng)豎井、排風(fēng)豎井,進(jìn)風(fēng)口應(yīng)設(shè)在地面潔凈處,若能與地面主樓有一定范圍更好,其受火災(zāi)煙氣影響會(huì)小。軟接材料一般為帆布或人造革,其具體尺寸可根據(jù)現(xiàn)場(chǎng)施工情況和風(fēng)機(jī)的機(jī)號(hào)來確定; (3)水泵兩端的管道連接的地方也要加裝軟性橡膠連接; (4)在安裝支撐懸吊架或減震裝置前,設(shè)備和管道的連接應(yīng)該通過軟管或管道繞性連接。機(jī)房?jī)?nèi)應(yīng)設(shè)值班室、控制室、維修間和衛(wèi)生間等。對(duì)于表冷器和加熱器可在總?cè)肟诨蚍种Ч苈飞显O(shè)過濾器。總冷量: Q=(1+10%)=因?yàn)橹评湎到y(tǒng)的冷負(fù)荷大于1160 KW,但是主副樓的兩個(gè)系統(tǒng)分開設(shè)計(jì),所以考慮宜選用離心式或螺桿式制冷機(jī)組。 (64)式中:——管段總阻力 ——管段部件的局部阻力 ——管段沿程阻力 本次設(shè)計(jì)風(fēng)管材料采用鍍鋅薄鋼板,風(fēng)管形狀選用矩形風(fēng)管。 初選散流器(3)計(jì)算射程() (51)式中:—以散流器中心為起點(diǎn)的射流水平距離; —在處的最大風(fēng)速; —出口喉部送風(fēng)速度; —平送射流原點(diǎn)距離風(fēng)口中心的長(zhǎng)度,; —風(fēng)口的實(shí)際流通面積m2; —系數(shù)。根據(jù)上訴的參數(shù)結(jié)合建筑物的特點(diǎn)性質(zhì)及工藝特點(diǎn)選擇合理的氣流組織方案。根據(jù)空氣處理的過程,繪制出焓濕圖如下:(1)空調(diào)房間的風(fēng)量 (2)風(fēng)盤風(fēng)量 (3)風(fēng)量關(guān)系 具體的計(jì)算實(shí)例數(shù)據(jù)見風(fēng)量計(jì)算附表考慮到五層到七層的房間主要功能是客房標(biāo)間,因此風(fēng)機(jī)盤管主要采用吊頂臥室暗裝,送風(fēng)口采用側(cè)送方式,休息廳采用下送散流器。夏季,室外空氣送入室內(nèi)需要的冷負(fù)荷按下式計(jì)算: (39)式中:——處理新風(fēng)需要的冷負(fù)荷,;——單位時(shí)間的風(fēng)量,;——房間外部狀態(tài)點(diǎn)的焓,;——空調(diào)房間的焓值。 圍護(hù)結(jié)構(gòu)瞬變傳熱引起的冷負(fù)荷外墻和屋面瞬變傳熱引起的冷負(fù)荷:在太陽和室外溫度的綜合影響,墻和瞬態(tài)熱傳導(dǎo)的逐時(shí)負(fù)荷引起的屋頂可以計(jì)算如下: (31) (32)式中 ——土建結(jié)構(gòu)傳熱,; ——外墻和屋面的面積,; ——建筑結(jié)構(gòu)傳熱系數(shù),/(優(yōu)優(yōu)點(diǎn)1)安放靈動(dòng),能夠和集中處理的新風(fēng)系統(tǒng)結(jié)合使用,也可以獨(dú)自使用2)空調(diào)房間互不干涉,可自主調(diào)節(jié)室溫,并可隨時(shí)根據(jù)需要啟動(dòng)停止裝置,節(jié)省運(yùn)行成本,靈活性高,節(jié)能效果好3)與集中式空調(diào)相比不需回風(fēng)管道,節(jié)約建筑空間4)機(jī)組部件多為裝配式、定型化、規(guī)格化程度高,便于用戶選擇和安裝5)只需新風(fēng)空調(diào)機(jī)房,機(jī)房面積小6)使用季節(jié)長(zhǎng),可以保證空調(diào)質(zhì)量7)各房間之間不會(huì)互相污染新風(fēng)系統(tǒng)提供新鮮空氣,同時(shí)完成室內(nèi)正壓和新風(fēng)的需求。設(shè)計(jì)是蘇州市隆鑫大廈空調(diào)及通風(fēng)工程設(shè)計(jì),主要功能為商務(wù)、餐飲、娛樂、辦公性質(zhì)的綜合樓,每層樓的功能基本相同,總體功能綜合型強(qiáng);寫字間樓層的廁所通風(fēng)設(shè)置獨(dú)立的排氣系統(tǒng),消防樓梯可靠的外窗進(jìn)行自然排煙。其他按1人/20 。外門: 5. 如果空調(diào)房間要求空調(diào)狀態(tài)相差挺大,并要求溫度單獨(dú)調(diào)節(jié)的辦公、商業(yè)等建筑,如有較大的需全年供冷的區(qū)域,在冬季或過渡季節(jié)需同時(shí)供冷與供熱, 且所需供冷量較大時(shí)可采用水環(huán)式水源熱泵空調(diào)系統(tǒng)。根據(jù)建筑物的走向以及每個(gè)區(qū)域房間的使用情況,對(duì)水系統(tǒng)的整體進(jìn)行水平和縱向的劃分,力求每個(gè)系統(tǒng)的冷量分配均勻,系統(tǒng)管路阻力和壓力不能超過規(guī)范的規(guī)定值。我國(guó)通常采用冷負(fù)荷系數(shù)法和諧波反應(yīng)法,冷負(fù)荷系數(shù)法是基于傳遞函數(shù)法,計(jì)算工程的一種簡(jiǎn)化計(jì)算的過程。其計(jì)算式按下列計(jì)算: (37)式中 ——照明冷負(fù)荷,; ——辦公室的面積,; ——負(fù)荷的密度w/ m2因?yàn)檫@里都是標(biāo)準(zhǔn)客房、寫字間所以取=11 w/ m2。新風(fēng)需處理到與室內(nèi)狀態(tài)點(diǎn)等焓值處,新風(fēng)單獨(dú)送入室內(nèi),不承擔(dān)多于負(fù)荷,室內(nèi)負(fù)荷由風(fēng)盤解決。因此,對(duì)設(shè)備的氣流組織進(jìn)行計(jì)算是十分重要也是十分必要的。(2)初選送風(fēng)口 按3m/s選擇風(fēng)口,選擇頸部尺寸為400mm100mm的百葉風(fēng)口。(5)通過得到的阻力及風(fēng)量選出需要的風(fēng)機(jī)來。制冷系統(tǒng)的制冷量應(yīng)包括用戶實(shí)際所需的制冷量以及制冷系統(tǒng)本身和供冷系統(tǒng)冷損失,按下式計(jì)算 (71)式中 : ——制冷機(jī)房的制冷量,; ——管路系統(tǒng)的實(shí)際需要的制冷量,; ——冷損失附加系數(shù),m=,。選用100010001000補(bǔ)水量為 ,選用JK200—3502型自動(dòng)化軟水設(shè)備。 (1)制冷機(jī)房最好設(shè)置在系統(tǒng)的中心位置,盡量做到節(jié)省管材。風(fēng)壓較低的風(fēng)機(jī)的機(jī)座,選用堅(jiān)固型的鋼機(jī)構(gòu);(2)為了避免設(shè)備之間產(chǎn)生共振的現(xiàn)象,不能多個(gè)設(shè)備共同用一個(gè)基座,要為每臺(tái)設(shè)備單獨(dú)設(shè)置專屬的基座;(3)工程中一般使用軟木木墊、橡膠減震墊、海綿乳膠等有彈性的具有韌性和柔性的減震材料。、排煙方式地下停車庫的通風(fēng)、排煙風(fēng)機(jī)可以采用離心風(fēng)機(jī)或排煙軸流風(fēng)機(jī),并應(yīng)在排煙管上設(shè)有排煙防火閥,當(dāng)煙氣溫度超過280時(shí),能夠自動(dòng)關(guān)閉,避免火災(zāi)通過風(fēng)道蔓延。另外15%20%補(bǔ)風(fēng)由門窗縫隙和成庫的出入口等處滲入補(bǔ)充。根據(jù)我國(guó)目前的《全國(guó)民用建筑工程設(shè)計(jì)技術(shù)措施暖通空調(diào)》規(guī)定:停車庫機(jī)械通風(fēng)的排風(fēng)量,按下式計(jì)算:一般停車庫為單層停放,可按照體積換氣次數(shù)來計(jì)算:汽車出入頻繁的商業(yè)類建筑,按次換氣次數(shù)。(6) 在對(duì)設(shè)備的位置進(jìn)行設(shè)計(jì)和選址的前期,應(yīng)該充分參考設(shè)備安裝說明以及安裝施工規(guī)范,保證設(shè)備正確安裝的前提下還需保證設(shè)備的安裝和修理的預(yù)留空間。閥門一般用于檢修時(shí)關(guān)閉,也能調(diào)節(jié)系統(tǒng)流量。冷卻塔是對(duì)冷卻水進(jìn)行降溫的設(shè)備,為提高換熱效率,配有風(fēng)機(jī)則冷卻水量: (7—4)式中:—冷卻水量m3/h; —總制冷量Kw; —冷卻水比熱,℃;—冷凍水進(jìn)/出口溫度,那么冷卻水量為: G=247。按照水力計(jì)算的步驟得到:最不利環(huán)路阻力(Pa)46980最有利環(huán)路阻力20945樓層內(nèi)不平衡率%編號(hào)Q(W)G(kg/h)L(m)D(mm)υ(m/s)R(Pa/m)ΣξΔPy(Pa)ΔPj(Pa)ΔP(Pa)不平衡率FG1417005015694081977%FG22340040984361020%FG32070040
點(diǎn)擊復(fù)制文檔內(nèi)容
試題試卷相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1