【正文】
Fi=FEK 層 次層 高(m)高 度(m)重 量 (KN)GiHiFi=FEK 剪力 Vi5202485419011331455252100939158582根據(jù)《建筑抗震設(shè)計(jì)規(guī)范》(GB50011—2010)的要求,本結(jié)構(gòu)須進(jìn)行多遇地震作用下的抗震變形驗(yàn)算,要對(duì)結(jié)構(gòu)的變形加以限制,使其層間彈性位移以及結(jié)構(gòu)頂點(diǎn)位移不超過(guò)一定的限值。m MBA=MCD=(+)= 水平地震荷載作用下的V圖(單位:kN)注:從左至右依次為A、B、C、D柱。m第四層:MAB=MDC=+=m)注:從左至右依次為A、B、C、D柱。用分層法計(jì)算梁、柱端的彎矩(1))第五層 恒載作用下第五層梁、柱端彎矩傳遞位 置A 節(jié) 點(diǎn)B 節(jié) 點(diǎn)E節(jié)點(diǎn)下 柱右 梁左 梁下 柱右 梁左 梁分配系數(shù)—固端彎矩A彎矩分、傳B彎矩分、傳A彎矩分、傳B彎矩分、傳A彎矩分、傳B彎矩分、傳A彎矩分、傳最后彎矩柱另端彎矩注:,節(jié)點(diǎn)B向節(jié)點(diǎn)E傳遞彎矩系數(shù)為1。屋面框架梁線載標(biāo)準(zhǔn)值屋面活載為 屋面板傳給邊跨梁的線載為: 2= 屋面板傳給中跨梁的線載為: 2=樓面框架梁線載標(biāo)準(zhǔn)值辦公室樓面活載為 過(guò)道樓面活載為 樓面板傳給邊跨梁的線載為: 2= 樓面板傳給中跨梁的線載為: 2=屋面框架節(jié)點(diǎn)集中荷載標(biāo)準(zhǔn)值(1)邊柱縱向框架梁傳來(lái)的屋面板荷載 GA=GD=(2)中柱縱向框架梁傳來(lái)的屋面板荷載 (+)/2= GB=GC=樓面框架節(jié)點(diǎn)集中荷載標(biāo)準(zhǔn)值(1)邊柱縱向框架梁傳來(lái)的樓面板荷載 GA=GD=(2)中柱縱向框架梁傳來(lái)的樓面板荷載 (+)/2= GB=GC=豎向活載作用下的結(jié)構(gòu)計(jì)算簡(jiǎn)圖注:從左至右依次為A、B、C、D柱。利用支座彎矩和實(shí)際荷載求邊跨跨中彎矩各層梁邊跨的跨中彎矩為:第五層:M中=-+() = kN177。177。177。m,MBC= kNm,MBC= kN內(nèi)力組合①+②①+(②+③)①+②+④ 截 面 號(hào) 荷 載 類 型四 層A+BB+恒 載①活 載②風(fēng) 載③177。177。 177。177。 177。內(nèi)力組合①+②①+(②+③)①+②+④ 截 面 號(hào) 荷 載 類 型二 層A+BB+恒 載①活 載②風(fēng) 載③177。177。m,MB=- kNm、MA+= kN177。177。金陵科技學(xué)院學(xué)士學(xué)位論文 第4章 梁、柱的內(nèi)力組合4梁、柱的內(nèi)力組 合 在進(jìn)行梁的內(nèi)力組合時(shí),每層的框架梁均取邊跨左支座、邊跨跨中、邊跨右支座、中跨支座和中跨跨中五個(gè)截面來(lái)進(jìn)行。(2)第四層、第三層、第二層 活載作用下中間層梁、柱端的彎矩傳遞位 置A 節(jié) 點(diǎn)B 節(jié) 點(diǎn)E節(jié)點(diǎn)上柱下柱右梁左梁上柱下柱右梁左梁分配系數(shù)-固端彎矩A彎矩分、傳B彎矩分、傳A彎矩分、傳B彎矩分、傳A彎矩分、傳B彎矩分、傳最后彎矩柱另端彎矩 注:,節(jié)點(diǎn)B向節(jié)點(diǎn)E傳遞彎矩系數(shù)為1。 恒載下柱軸力圖(kN)注:從左至右依次為A、B、C、D柱。m MEB =-ql2=-=-m風(fēng)荷載作用下的框架內(nèi)力圖(左向)框架的彎矩圖由柱端彎矩和梁端彎矩可以直接做出,彎矩圖畫在構(gòu)件的受拉邊,不標(biāo)正負(fù)號(hào)。m)注:從左至右依次為A、B、C、D柱??蚣艿募袅D根據(jù)框架彎矩圖,通過(guò)對(duì)梁或柱取脫離體,求某一點(diǎn)ΣM=0,則可以求出梁端和柱端剪力,然后即可做出剪力圖。梁端彎矩計(jì)算——根據(jù)節(jié)點(diǎn)平衡來(lái)計(jì)算第五層:MAB=MDC=5434172090544341720905343417209052434172090513435213540注:底層=,α=;非底層=,α=④邊框架邊柱側(cè)移剛度D值的計(jì)算層次截面 (m2) 層高 (m)線剛度αD=α——凝土軸心抗壓強(qiáng)度設(shè)計(jì)值,對(duì)于C30。(1)基礎(chǔ)(墻基)防潮層:,20厚的1:2水泥砂漿摻5%避水漿,適用于磚墻墻身。 根據(jù)《建筑采光設(shè)計(jì)標(biāo)準(zhǔn)》(GB/T500332001):教室為III級(jí)采光,面積比大于1/5;走廊和樓梯間為V級(jí)采光,面積比大于1/12。500;層數(shù):5層;合理布置教室、衛(wèi)生間、老師休息室、管理辦公室、值班室、開水房等;層高:。 Secondly, pleted a load of the structural ponent of the framework of the reinforcement design, handpainted structural construction blueprint, and pleted the entire structure design. The whole design programs satisfy the state standard requirements in respect of architecture and structure,the construction design satisfy the reality on the ground.The instruction booklet introduce a load of frame, First of all, selecte the type of structure, calculate and analyze the framework of the load, by the stratification and method D calculate respectively the internal forces of frame on the act of vertical load and wind loads . Through the bination of internal forces, conclude the control framework drawn forces, Finally , finishe the reinforcing bar calculation about the ponents of framework , and paint structural construction drawing. The booklet also design a foundation and stairs, and conclude the reinforcing bar calculation of the stairs and the base, and plete their structural construction blueprint.Key words: Construction Design。 The Frame。走廊、。教室采光面積比為1/5樓梯間: 1/12均滿足要求。(2)地面:人造大理石板地面10厚1:2水泥砂漿找平層120厚C30混凝土100厚素土夯實(shí)(3)樓面:人造大理石板地面20厚1:2水泥砂漿找平層120厚鋼筋混凝土樓板10厚底板抹灰(4)踢腳臺(tái)度做法:釉面瓷磚踢腳臺(tái)度5厚釉面磚(白瓷磚)水泥擦縫5厚1:1水泥細(xì)砂結(jié)合層12厚1:3水泥砂漿打底(5)內(nèi)墻面做法: 水泥砂漿粉面:刷(噴)內(nèi)墻涂料10厚1:2水泥砂漿抹面15厚1:3水泥砂漿打底(6)外墻面:用15厚1:3水泥沙漿找平,20060高級(jí)無(wú)釉質(zhì)瓷磚飾面。(3)計(jì)算過(guò)程現(xiàn)只計(jì)算中柱,邊柱以中柱為準(zhǔn):=155=AC≥ /=1000/()= b=h=mm=取b=h=500mm500mm。5434171567844341715678343417156782434171567813435211748注:底層=,α=;非底層=,α=(3)各層柱側(cè)移剛度之和(層間剛度)的計(jì)算層次中框架中柱中框架邊柱邊框架中柱邊框架邊柱∑D52371922=5218181849222=406824209054=83620156784=62712107497445218184068248362062712107497435218184068248362062712107497425218184068248362062712107497411473522=3241701274422=280368135404=54160117484=46992705690結(jié)構(gòu)基本自振周期T1的計(jì)算層次各層重量(kN)總重量(kN)層間剛度∑DiΔui=∑um=∑Δui510749744107497431074974210749741705690采用頂點(diǎn)位移法計(jì)算結(jié)構(gòu)基本自振周期T1=a0== s <== s注:上式中,對(duì)于民用框架結(jié)構(gòu)周期調(diào)整系數(shù)取a0=~,本設(shè)計(jì)取a0=;對(duì)于Ⅲ類場(chǎng)地土,設(shè)計(jì)地震分組為第一組,取特征周期值Tg= s橫向水平地震作用的計(jì)算本設(shè)計(jì)的建筑為7度近震,地震影響系數(shù)αmax=,則相應(yīng)于基本自振周期的α1值為:α1=αmaxm MBA=MCD== kN框架軸力圖即柱軸力圖,根據(jù)框架剪力圖,取節(jié)點(diǎn)脫離體,求ΣY=0,即可求出柱的軸力圖,軸力以柱受壓為正。梁端彎矩計(jì)算——根據(jù)節(jié)點(diǎn)平衡來(lái)計(jì)算第五層:MAB=MDC=框架的剪力圖根據(jù)框架彎矩圖,通過(guò)對(duì)梁或柱取脫離體,求某一點(diǎn)ΣM=0,則可以求出梁端和柱端剪力,然后即可做出剪力圖。m 第三層、第二層、第一層各梁端的固端彎矩