【正文】
1KV 以下母線橋絕緣值大于 1MΩ While generatrix installation, it should tighten the fix bolts between section and section, ensure the interface of every phase ply with engineering request. Isolation value of isolation layer between 2 phases meets the specification. Isolation value of generatrix bridge below 1Kv 1MΩ. 母線橋安裝保證橫平豎直,直線度和水平度誤差在允許安裝范圍內(nèi)。應(yīng)盡量避免安裝后的返工或返修,否則,將前功盡棄。安裝時要保證觸頭連接處可靠接觸,安裝前先裝好內(nèi)屏蔽罩及導(dǎo)電桿并將外均壓環(huán)先套在套管上,套管上、下密封面按要求進行可靠處理。 Adjust main generatrix center location by plumb and jack, center line error 177。 Align the panels one by one according to designer’s requirement, (tightening piece shall be galvanized) 盤、柜及盤、柜內(nèi)設(shè)備與各構(gòu)件間連接應(yīng)牢固。 Butt connection of section steel on foundation shall be carried out by skilled welder. Section steel shall be fabricated in sections to be convenient for transportation. 嚴(yán)格按照施工圖所示尺寸,并結(jié)合制造 廠產(chǎn)品樣品,測量各種盤柜的準(zhǔn)確尺寸,尤其是確保母線橋的安裝尺寸。 After transformer installation qualified, install the accessories: due to the junction box, oil 中國 第十一建設(shè)有限公司寧夏哈納斯工程項目部 化 學(xué) 工 程 China Eleventh Chemical Construction Company Limited NingXia Hanas Project 12 / 29 box, radiation fins and thermometer of 110Kv transformer is separated, so accessoried installation is key to transformer installation. We plan use 25t mobile crane assist accessories installation (the heavyest oil box cover is ), pay attention to seal while accessoried installation, especially the oilway seal fits have to pletely and properly. After accessories installation finish, sampling oil from transformer body and infuseoil 500g, send to oil mix examinating by professional lab, oiling after examined, oiling to scale according to manufacturer. After 24 hours from oiling finish, check the leakage, go to next procedure if in good condition. 就地的溫度計只需在溫水里面試驗一下保證讀數(shù)正確,即可安裝,安裝時在溫度計套管里面放少許變壓器油即可。 gear list 序號/No. 名稱 /Equipment 型 號 規(guī) 格 / Type 單位/Unit 數(shù)量 /Qty 備注 /Note 1 汽車吊 /Mobile Crane QY100H2 150t 臺 /Set 1 2 吊裝帶 / Lfting Belt 10t 根 /Pic. 2 3 卸扣 / Shackle 80t amp。 本次吊裝站車位臵有兩處,一處在變電所東側(cè) 110KV 變壓器旁,一處在變電所西側(cè) V8 管廊旁,吊車移動與站車區(qū)域場地地基需處理,地基需推平壓實,滿足吊裝要求。 HV amp。 Utility Substation 3 自耦變壓器 / autotransformer 2 8000 二層 /2nd Floor 立式 /vertical 110變電所 / Substation 110 4 10KV中壓柜 / MV Cabi 29 800 二層 /2nd Floor 立式 /vertical 110變電所 / Substation 110 5 低壓柜及保護柜 / LV Cabi 137 800 二層 /2nd Floor 立式 /vertical 110變電所及公用站變電所 Substation 110 amp。裝車后,必須用繩索進行封車,才能進行運輸。此平臺是 7055U003DW1642009 圖紙上設(shè)計的,平臺的設(shè)計承重荷載是 25KN/m2。確定位臵后,應(yīng)用角鋼將變壓器固定在基礎(chǔ)槽上。 Local thermometer test in water bath to ensure the correct reading and then installed, oiling into thermometer sleeve. 10KV 變壓器的安裝,由于是干式變壓器,變壓器按照設(shè)計位臵固定后,安裝溫控器,檢查散熱風(fēng)扇齊全即可。 Roof, floor construction finished, it can’t have leakage, internal flooring finished, ditch clean and no sundries and seeper. 預(yù)埋件及預(yù)埋 孔符合設(shè)計要求。采用吊車、鋼管、千斤頂?shù)裙C具,將所有間隔主母線單 元初步就位。 采用定位銷對接主母線法蘭,以保證法蘭對正,緊固連接螺栓。如果吸附劑裝入 GIS 內(nèi),又不對密封罐立即抽真空,則超過 4 小時后應(yīng)重新處理,再放入。合格后方可安裝。 The special bolt for desi。 1kv generatrix bridge is intensive type. 空氣絕緣型母線橋的安裝主要是把支架安裝牢固后,把母線橋外殼安裝在支架上。 Seal ring installation: remove seal ring protection shield, inspect surface for roughness and damage, if it damaged slightly, polish by 1000 sand paper, if damage seriously, it should change into new ponent. Use wipe paper dipping alcohol to clean surface of seal ring and seal slot. 法蘭連接螺 栓的緊固一律采用力矩扳手緊固,力矩值參考 母線緊固表 。檢測主母線對接觸頭尺寸,保證插入深度38177。 The assemblyed ponents by manufacturer can’t disassembly optionally, if necessary, the disassembly has to perform under the manufacturer guide. GIS 主 要 元 器 件安裝 / GIS main ponents installation 基準(zhǔn)間隔就位 / Basic Distance Location 以主母線單元為最先就位設(shè)備,按照廠家提供的裝箱清單及 設(shè)備安裝順序 ,將 設(shè)備 吊入110KV GIS 安裝 地點,再進行拼裝。 The construction quality releated building, structure to cabi installation should ply with state existing regulate of construction and acception. 屋頂、樓板施工完畢,不得滲漏。接線箱安裝主要是保證不能碰到瓷瓶,螺栓固定牢靠。 Accessories Installation 變壓器前 吊裝 檢查變壓器的基礎(chǔ)道軌寬度與變壓器道軌寬度一致。 選用吊裝帶 / Lifting Belt Selection:吊裝帶選用 10t;安全 /Safe 設(shè)備卸車 / Unload 中國 第十一建設(shè)有限公司寧夏哈納斯工程項目部 化 學(xué) 工 程 China Eleventh Chemical Construction Company Limited NingXia Hanas Project 8 / 29 110KV 變壓器卸車 / Unload of 110Kv transformer 變壓器在吊裝前,吊車先進場,進場前先平整場地,場地平整時達到 150T 汽車吊占車需要的地面壓實要求,吊裝場地應(yīng)無雜物等影響吊裝作業(yè)。 起重索具應(yīng)檢查可靠、起吊時盤柜應(yīng)使用吊裝帶兜底吊裝。 TOOLS ................................................................25 10 勞動力安排 /MANPOWE SCHEDULE ..........................................................................................26 11 三種吊車性能表 / MOBILE CRANE LIFTING GRAPH ....................................................................26 中國 第十一建設(shè)有限公司寧夏哈納斯工程項目部 化 學(xué) 工 程 China Eleventh Chemical Construction Company Limited NingXia Hanas Project 2 / 29 1 工程概況 /Project General 根據(jù) Technip 設(shè)計的哈納斯 LNG 項目變電所的設(shè)備布臵圖要求,在變電所安裝 110KV 變壓器 2 臺,單臺質(zhì)量為 62t(除去現(xiàn)場組裝的附件質(zhì)量); 8 臺干式變壓器 ,2 臺自耦變壓器,最大的質(zhì)量是 8t; 153 面電氣盤柜,其質(zhì)量在 1t 以下;由于本次設(shè)備吊裝有質(zhì)量較大的設(shè)備,為保證吊裝順利進行和設(shè)備按要求安裝,特編制此方案,以指導(dǎo) 施工。 出廠的有關(guān)資料及產(chǎn)品證明文件齊全。 one is next to 110 Kv transformer on east side of substation, another one in on west side of substation, next piperack V8. Crane setup area should leveling and tamp to fit lifting. Crane setup location see DWG1 please. 吊車站位附圖 一 /DWG1(crane setup) 中國 第十一建設(shè)有限公司寧夏哈納斯工程項目部 化 學(xué) 工 程 China Eleventh Chemical Construction Company Limited NingXia Hanas Project 5 / 29 設(shè)備吊裝 /Lifting 吊裝施工工藝 Lifting Process 技術(shù)準(zhǔn)備→現(xiàn)場準(zhǔn)備及場地處理→設(shè)備運輸就位→吊車達到作業(yè)條件→吊裝索具拴掛→試吊檢查及處理→吊起→設(shè)備落至道木垛→吊車摘鉤 →設(shè)備移位至安裝位臵→吊起→抽出滾杠→落下就位→吊裝完成 Technology preparation→ site preparation amp。 Subtransformer shape steel support of substation designed as 10 channel steel for out frame, 10 channel steel for inside, standing installation, painting and touchup after shape steel installation. 中國 第十一建設(shè)有限公司寧夏哈納斯工程項目部 化 學(xué) 工 程 China Eleventh Chemical Construction Company Limited NingXia Hanas Project 11 / 29 在鋼制平臺上將型鋼的平面及立面分別平整,校直,全長偏差控制在 15mm 之內(nèi)(包括平面和立面)。溫度計盤面應(yīng)對著巡檢易視處,金屬毛細管的彎曲半徑不得小于 50mm。本裝臵的預(yù) 埋