【正文】
ed by 69%.Adding smoke detectors would reduce the death rate by a further 13%, resulting a total reduction in the death rate of 82% (Hall, 1993). ??Sprinklers do not operate properly 8% of the time and smoke detectors do not operate properly 15% of the time (Hall, 1993). ??Detectors are nonoperational 32% of the time when a fire occurs (Hall, 1993). This information of this type would be very useful in a quantitative risk assessment, however for other fire safety measures it is not readily available. In addition to this, it is difficult to assess the contribution of an individual fire safety measure to the safety of occupants. The safety of occupants is usually provided through the bination and interaction of different fire safety measures. Therefore the assessment of the contribution to life safety from individual safety measures is difficult without the consideration of these interdependencies. Another problem is that some fire safety measures provide protection indirectly. For example 18 sprinkler protection would provide direct protection, but smoke detectors will provide indirect protection. Direct protection can be defined as the fire safety measures that can directly affect the fire or products of bustion. The limited information and data available makes it difficult to assess the matrix quantitatively. A relative risk assessment of the matrix with respect to the building code would be the next logical stage, but the statistics on the effectiveness of the fire safety systems is limited. Reliability data is relatively easy to determine, but data on the ability of a fire safety measure or a bination of measures to increase life safety is difficult to determine. Some of the problems with a quantitative risk assessment are: ??Limited data ??Assessment of matrix variables Fire safety systems. Assessment of reliability and effectiveness of fire safety systems. Fire. Assessment of fire growth, spread, production of toxic products. Building characteristics. Level of safety provided by architectural characteristics, number of stairs, egress path widths, travel distances. Occupant characteristics. Assessment of occupant characteristics, human behaviour, physical and mental abilities. Training and Education. Decision making ability of occupants. Maintenance and inspections. Assess the frequency and effectiveness of maintenance program. Fire brigade intervention. Assessment of response time of fire brigade and time to extinguish or control the fire. ??Assessment of interdependencies and interrelationships between matrix variables. For example, the fire size is related to the ability of sprinklers to control the fire. ??Changes to the risk to life safety during a fire. Occupant behaviour, occupant location, occupant characteristics, fire characteristics, fire safety measures and fire brigade intervention can all change as the situation evolves. Therefore the level of risk faced by occupants also changes. To avoid the inherent difficulties in quantitative risk assessment, the fire safety design matrix is based on providing multiple levels of protection for the occupants. Therefore, if one of the fire safety measures fails, there is at least one other mechanism to provide protection. In addition to this, fire safety training is essential to educate occupants on what to do in the event of a fire, and 19 how to maximise their chances of survival. 中文譯文: 第十三章 防火安全矩陣 防火安全矩陣 以 為公寓 防 火工程設計提供指南 為 宗旨。其它居住者保留在他們的屋子 , 等待消防隊協(xié)助 、 忠告 或 在 被 保護 的 地方 執(zhí)行 活動 。這些 可變量 必須一致地被認為提供多數(shù)有效的設計。 低和高保護 在于 區(qū)別 已 21 3 被動保護 耐火性規(guī)定值 自已 closers 在門 走廊里 的防煙門 煙和火制音器 火災定級 的逃命道路 低被動保護 高被動保護 4 避難地區(qū) 避難 樓層 避難 域 逃脫的居住者和仍留在他們房間的居住者,在他們房間的居住者部分會受到保護或處于一中低的受保護水平。 煙控制 分隔 包括煙大廳和走廊煙障礙。并且 這 中 方法 被 用來 評估哪 中 突發(fā)事件的策略 更 有效 , 或 在相同建筑條件下哪 中 灑水裝置更有用 。 此 矩陣 提供了對公寓建筑的受歡迎的防火安全方法,這些方法充分考慮到噴水龍頭保護和突發(fā)事件。聲音強度達在 關閉 時 到極小值 75 dB。 選擇 使 各個 樓層的火 是分開的隔間和垂直 的軸是分開的火隔間。 在危險中 的 居住者 以下矩陣概述是多數(shù)在危險中的居住者 能遇到的 三 中 情況 和三個緊急戰(zhàn)略 ,。 1 撤離 警 告 所有居住者撤離建筑物。矩陣 僅僅作 為 能 指 導和 適當?shù)睾藢嵑细穹阑鸢踩こ痰淖詈笤O計。 3 分批 撤離 居住 在 火災發(fā)生的房間的和火災層的人員 首先撤離。 防火安全 措施 的選擇 在許多情況下 是有很多 中 的 。 避難所地區(qū)應該提供 給殘疾 人 或他們 被 指示保留在他們公寓。 密封 系統(tǒng)不應該激活在火的偵查在區(qū)域是被 密封 的區(qū)域 。被推薦的防火安全方案 的理由 將 中 講述 。 高于 25 米的建筑 高于 25 米的建筑的 防火安全矩陣 在 表 15 中 介紹 。 報警系統(tǒng) 如果在公寓內將是更有效。 表 14 矩陣 可變量 可變量 次級 可變量 評論 建筑物和 出 口 特征 1 建筑物特征 建筑物高度 多居 民 或 多用途 房屋面積 公寓 數(shù)量 安全 防護 2 出 口 特征 臺階的數(shù) 目 緊急 電梯 被保護的道路 逃出距離 出口 寬度 應急照明和標志 通常建筑管理,強制保護 。 消防隊干預可能 改變 撤離 順序 , 或制止撤離以回應當前情況或任何改變。 緊急戰(zhàn)略 緊急戰(zhàn)略的簡要的描述或緊急辦法 在下面的情況下的 矩陣中被使用 。 在公寓設計 中 應該被考慮的三 中 情況 是 : 在公寓悶燃的火 , 在公寓的明火 和 公共空間的火 (即 臺階和走廊 ) 。 剩下 的居住者 按順序撤離 。例如 , 噴水 裝置保護能降低建筑物火災發(fā)生率,并允許消防隊到達時間延長。這需要 編入 建筑物的緊急 計劃 。 這是防止煙傳播。 表 15 防火安全矩陣 : 高于 25m 的建筑 噴水 龍 頭保護 非噴水 龍 頭保護 撤離 1 FRR 30 2 避難所 3 密封的樓梯 4 自動關閉 和煙封印公寓和逃命道路。 外在火傳播包括 三角壁 、陽臺和分離距離。 推薦使用 硬聯(lián)線探測器。 表 14 列出應該被考慮的一些 建筑物 的 防火安全措施 , 被提出 的 可變量 并 不是 全面 的 , 其它防火安全措施也許 更適合 更加復雜的設計 。在 起火層 之下 的 居住者 最后 被 疏散。下列是應該被提供在所有公寓防火安全名單的方案 : 1 煙檢測器 2 熱化、透氣和空調 (HVAC) 系統(tǒng)在火警報 時 關閉 3 垂直的軸之間和地板 之間最小 耐火 時間是 30 分鐘 。 不 考慮 建筑物和居住者特征 , 一些最小的防火安全措施 應該 被實施在所有公寓。 立即撤離那些在起火層之上的居住者 。 這些交易和相互聯(lián)系在防火安全措施之間需要被認為獲得多數(shù)高效率和有效的防火安全設計。 防火安全系統(tǒng) 1 偵查 煙檢測器 熱探測器 模式可尋址的系統(tǒng) 中心 探測器 /手工電話點 2 警報 發(fā)聲器 緊急警告和相互 交流 系統(tǒng) (EWIS) 與消防隊的 聯(lián)系 火顯示盤區(qū) 仿造盤區(qū) 3 滅火 噴水 保護裝置 滅火器 滅火水龍帶卷軸 消 火栓 煙檢測器應該被提供在所有公寓。 緊急辦法 撤離 非撤離 分批 撤離 檢查和維護 檢修頻率 逃命道路維護和 遠離 可燃燒物 按 相關標準和建 筑條例進行維護 訓練和教育 消防演習頻率 防火安全簡報 小冊子和文 章 用舞臺煙霧 模仿現(xiàn)實情況 防火安全訓練和緊急狀態(tài)計劃訓練 建筑物 負責人 居住者特征 年齡 心理上和體質上的特點 /易變性 教育 文化背景 消防隊干預 警報時間 (連接到消防隊 )時刻 到達公寓時刻 設定和 穿越樓層 時刻與起火 /搜尋 和搶救戰(zhàn)斗 與居住者的通信 23 可利用水 火 內部火傳播 外在火傳播 火增長率 火發(fā)展階段 火大小 圍墻影響 內部火傳播包括襯里 和可燃燒的材料