freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內容

★紡織廠10kv供配電畢業(yè)設計(完整版)

2025-01-16 11:24上一頁面

下一頁面
  

【正文】 量: MV AMV AX SS kd )4()3(4k ??? ? ?? K5 點短路計算 求 K5 點 ( ) 的短路電路和總電抗及三相短路電流和短路容量 (1)總電抗標幺值 )5( ??????? ?????? XXXX k (2)三相短路電流周期分量有效值 kAkVX II kd )5( 25k)3( ??? ? ??? )( (3)其他短路電流 kAIII 39。一般不應小于所在系統(tǒng)的額定電壓 NU 。當 stk 1? 時, kima tt ? 。 即 )3(koc II ? 或 )3(koc SS ? ( 63) 短路條件校驗 隔離開關、負荷開關和斷路器的短路穩(wěn)定度校驗 ( 1)動穩(wěn)定性校驗條件 )3(max shii ? 或 )3(max shII ? ( 64) 式中 maxi 、 maxI —開關的極限通過電流(又稱動穩(wěn)定電流)峰值和有效值,洛陽理工學院畢業(yè)設計(論文) 29 單位為 kA; )3(shi 、 )3(shI —開關所在處的三相短路沖擊電流瞬時值和有效值(單位kA) ( 2)熱穩(wěn)定校驗條件 imat tItI 2)3(2 ?? ( 65) 式中 tI —開關的熱穩(wěn)定電流有效值,單位為 kA。 )3(6k)3()3( ??? ? )( kAkAIi sh )3()3( ?????? kAkAII sh )3()3( ?????? (4)三相短路容量: MV AMV AX SS kd )6()3(6k ??? ? ?? 通過計算得表 51 表 51 短路點數(shù)據(jù)統(tǒng)計表 三相短路電流 /KA 三相短路容量 (MVA) 短路計算點 KI)3( )3(I? )3(?I shi shI )3(kS 1?K 2?K 3?K 4?K 5?K 6?K 洛陽理工學院畢業(yè)設計(論文) 28 第 6 章 高低壓電氣設備選擇 一次設備選擇與校驗的條件和項目 為保證一次設備安全可靠的運行,必須按下列條件選擇和校驗: (1)按正常工作條件包括電壓、電流、頻率及開斷電流等選擇。 2)3()3()3( ??? ?? kAkAIi sh )3()3( ?????? kAkAII sh )3()3( ?????? (4)三相短路容量: MV AMV AX SS kdK )2(2)3( ??? ? ??? K3 點短路計算 求 K3 點 ( ) 的短路電路和總電抗及三相短路電流和短路 容量 (1)總電抗標幺值 )3( ??????? ?????? XXXX k (2)三相短路電流周期分量有效值 kAkVX II kd )3( 23k)3( ??? ? ??? )( (3)其他短路電流 kAIII K 39。在等效電路圖上,只需將被計算的短路電流所流經(jīng)的一些主要元件表示出來,并標明其序號和阻抗值,然后將等效電路化簡。 低壓出線的選擇 饋電給各車間(鍛工車間、紡紗車間、制條車間、軟水站、機修車間、職工車間、染工車間、鍋爐房、水泵房、油泵房、化驗區(qū))用 VLV22 型聚氯乙烯絕緣鋁芯電纜。 (2)校驗短路熱穩(wěn)定 按式計算滿足短路熱穩(wěn)定的最小截面 22)3(m in 2277 mmmmCtIA im a ???? ?< A=25 2mm C 值由表查得 , imat 按終端變電所保護動作時間 ,加斷路器短路時間 ,再加 計,故 stima ? 。 由上可知,單母線分段便于分段檢修母線減小母線故障影響范圍,提高供電的可靠性和靈活性。 例如,固定式開關柜中的斷路器工作一段時間需要檢修時,在斷路器斷開電路的情況下,拉開隔離開關;恢復供電時,應先合隔離開關,然后合斷路器。 安全:要求選擇合適的電氣設備,具有良好的監(jiān)視和保護系統(tǒng),以保證人身和設備安全。39。由于它沒有旋轉部件,維護較為方便,為了在運行中調節(jié)電容器的功率,可將電容器連接成若干組,根據(jù)負荷變化,分組投入或切除。 5%,足以保證電壓質量。 2. 變壓器調壓方式選擇 視負荷大小、可靠性要求、電壓質量要求而定,一般車間變電所不使用有載調壓變壓器。239。 ?????? Tcc Q 22239。 ???? Ncc USI : ?cP ?cQ ?cS 3803 ???? Ncc USI ????? cT SP 4 2 6 79 2 6 239。39。 ?????? Tcc Q ??cS 22 ????? cc QP = AUSINcc 39。故: ( 1) TPPP ??? c39。 該廠有二級負荷這三級負荷。 1r? < 1。 電力負荷的表達式 電力負荷根據(jù)其對供電可靠性的要求及中斷供電在政治、經(jīng)濟上所造成損失或影響的程度,可分為三級:一級負荷、二級負荷、三級負荷。 ( 8) 變電所的防雷和接地設計,總降的電照設計。要求設計成果能應用于生產實際,能夠讓該供電系統(tǒng)安全、可靠、經(jīng)濟的分配電能,滿足工業(yè)生產的需要。 ( 3) 優(yōu)質 供電系統(tǒng)提供的電能應該滿足電力用戶對電壓、頻率等電能質量的要求。供電系統(tǒng)一旦確定,就決定了用戶內部用電負荷的供電可靠性和供電質量。本人完全意識到本聲明的法律后果由本人承 擔。從而使整個供電系統(tǒng)更 具有其可靠性和靈活性。 關鍵詞: 電源進線 短路計算 電氣設備選擇 繼電保護 洛陽理工學院畢業(yè)設計(論文) II 10kV Power Distribution Design of Textile Factory ABSTRACT With the development of factory automation, power supply system bees more and more important. It not only can guarantee normal production of the factory ,but also reduce the cost of the products, save the electrical energy and increase productivity. The paper is about the design of the supply and distribution system of a textile factory .It mainly includes the load calculation, the design of substation bus, the design of the inlet line and the high voltage distribution line, short circuit calculation, high and low voltage electrical equipment selection, the layout of the relay protection and the design of the lightningprotection and grounding. At the same time the design uses shunt capacitor to pensation reactive power to decrease energy losses and voltage losses in the power supply can also improve the quality of the power supply voltage. So the whole design of the power supply system bees more reliability and flexibility. KEY WORDS: power system, short circuit calculation, electrical equipment, relay protection 畢業(yè)設計(論文)原創(chuàng)性聲明和使用授權說明 原創(chuàng)性聲明 本人鄭重承諾:所呈交的畢業(yè)設計(論文),是我個人在指導教師的指導下進行的研究工作及取得的成果。 作者簽名: 日期: 年 月 日 學位論文版權使用授權書 本學位論文作者完全了解學校有關保留、使用學位論文的規(guī)定,同意學校保留并向國家有關部門或機構送交論文的復印件和電子版,允許論文被查閱和借閱。電能 易于轉換,易于傳輸,分配簡單經(jīng)濟,便于調節(jié)、控制和測量等特點,使得電能成為了工業(yè)生產的主要能源。 ( 4) 經(jīng)濟 在保證供電可靠性的情況下,供電系統(tǒng)的投資要盡量少,運行費用要盡量低,并盡可能的節(jié)約電能和減少有色金屬的消耗量。設計的具體步驟如下: ( 1) 按照廠區(qū)用電設備的資料 和其他具體情況,計算負荷。 ( 9) 需要核算建設所需器材與總投資。 年最大負 荷 maxP 就是全年中負荷最大的工作班內消耗電能最多的半小時平均負荷30P 。 用電設備組有功計算負荷: cP = edPK (kW ) (17) 用電設備的無功計算負荷: cQ = cP ?tan ( kvar) (18) 用電設備組的視在計算負荷為: cS = ?coscP = 22 cc QP ? ( kVA) (19) 5 用電設備組的計算電流為: cI =NcUS3 ( A) (110) 按二項式發(fā)確定三相用電設備組計算負 荷 . 同一工作制單組用電設備 有功計算負荷為 xec cPbPP ?? 無功計算負荷為 cQ = cP ?tan ( kvar) 式中 b、 c— 為二項式系數(shù),對于不同類型的設備取值不同。二級負荷也屬 于重要負荷,供電變壓器可由一臺或者兩臺變壓器。c ( 122) ( 2) Tcc Q ???39。39。 ???? Ncc USI : 710?cP 5..532?cQ ?cS 38 03 73 ???? Ncc USI ????? cT SP 2 1 039。 ?????? Tcc PPP 6 8 7 2 2 ????? cT SQ 8 7 39。239。39。 3. 變壓器相數(shù) 的 選擇 一般選擇三相變壓器。 表 12 變壓器型號一覽表 車間 變壓器型號 額定容 空載 負載 空載 阻抗 聯(lián)結 13 量(KVA) 損耗(kW) 損耗(kW) 電流(%) 電壓(%) 組標 號 車變 )6(10/10009 ?S 1000 Yyn0 車變 )6(10/2509 ?S 250 4 Yyn0 車變 )6(10/10009 ?S 1000 Yyn0 車變 )6(10/4009 ?S 400 1 4 Yyn0 車變 )6(10/2509 ?S 250 4 Yyn0 14 第 2 章 無功補償 無功補償方案設計 提高功率因數(shù)的意義 工廠中由于有大量的感應電動機、電焊機、電弧爐及 氣體放電燈等感性負荷,還有感性的電力變壓器,從而使功率因數(shù)降低。 本次設計為 10kV,從補償裝置的維護和性能的角度來考慮,就選用并聯(lián)電容器裝置。 ????? Cc qnQ 2239。 可靠:滿足各級負荷的不中斷供電要求。這就是隔離開關與斷路器配合操作的原 則。 電氣主接線詳見附錄 1。 因此 YJL2210000325 電纜滿足短路熱穩(wěn)定條件。饋電給倉庫用 BLV 鋁芯聚氯乙烯絕緣導線。對于工廠供電系統(tǒng)來說,由于將電力系統(tǒng)當作無限大容量電源,而且短路電路也比較簡單,因此一般只需采用阻抗串、并聯(lián)的方法即可將電路化簡,求出其等效總阻抗。39。 (2)按短路條件包括動動穩(wěn)定性和熱穩(wěn)定性進行校驗。 t—開關的熱穩(wěn)定試驗時間,單位為 s; )3(?I —開關所在處的三相短路穩(wěn)態(tài)電流,單位為 kA。
點擊復制文檔內容
公司管理相關推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1