畢業(yè)設(shè)計-330kv樞紐變電站設(shè)計-文庫吧在線文庫

2025-01-16 18:08上一頁面

下一頁面
  

【正文】 西安工程大學本科畢業(yè)設(shè)計(論文) 21 *100 1000* %2X2 === SN SBUk *100 1000* %3X3 === SN SBUk 對 OSFPSZ10- 360000/330 主變壓器: Uk1%=1/2[Uk(12)%+ Uk(13)% - Uk(23)%]=1/2(13+ 25- )= Uk2%=1/2[Uk(23)%+ Uk(21)% - Uk(13)%]=1/2(13+ - 25)=- Uk3%=1/2[Uk(31)%+ Uk(32)% - Uk(12)%]=1/2(25+ - 13)= X4=SNSBUk100%1=360*100 1000*= X5= SNSBUk100%2 = 360*100 1000*? =- X6= SNSBUk100%3 = 90*100 1000* = d1短路時 (330KV 母線 ) 其等效電路圖為 轉(zhuǎn)化為 西安工程大學本科畢業(yè)設(shè)計(論文) 22 再轉(zhuǎn)化為 再轉(zhuǎn)化為 * 32X 3/ / X 27 ==== ?? XX XXX * 56X 5/ / X 6X8 ????????? XX XX 0 . 3 50 . 3 60 . 0 17X1X9 =+=-= X? 0 . 1 5 1 0 =-== X? 1 7 ???? XXXX . 1 7 81111* ??? XI 短路電流有名值 KAU avSNII *310 00**` * ??? 沖擊電流 KAK s h I **2`2i s h ??? 式中 Ksh—— 沖擊系數(shù)。 短路電流計算的目的和條件 (1)短路電流計算的目的: 在發(fā)電廠和變電站的設(shè)計中,短路計算是其中的一個重要環(huán)節(jié)。 (3)在變電站安裝避雷針,在變壓器附近和線路上安裝避雷器,減少雷擊損害。短路時電壓下降的愈大,持續(xù)時間愈長,破壞整個電力系統(tǒng)穩(wěn)定運行的可能性 愈大。 例如,在發(fā)電機端發(fā)生短路時,流過發(fā)電機的短路電流最大瞬時值可達發(fā)電機額定電流的 10~ 15 倍,在大容量的電力系統(tǒng)中,短路電流可高達數(shù)萬安培。 經(jīng)短路電流計算,在 330 千伏變電所可能發(fā)生的各種短路類型中 ,330 千伏母線發(fā)生三相對稱短路時,短路電流最大, 110 千伏母線發(fā)生單相接地短路時,短路電流最大。缺點:調(diào)節(jié)速動慢,產(chǎn)生高次諧波。 減少設(shè)計容量 ,減少投資 ,增加電網(wǎng)中有功功率的輸送比例 ,以及降低線損都直接決定和影響著供電企業(yè)的經(jīng)濟效益 .所以 ,功率因數(shù)是考核經(jīng)濟效益的重要指標 ,規(guī)劃、實施無功補償勢在必行 . ( 4) 裝設(shè)無功補償裝置的 原因 在正常情況下,用電設(shè)備不但要從電源取得有功功率,同時還需要從電源取得無功功率。變壓器也同樣需要無功功率,才能使變壓器的一次線圈產(chǎn)生磁場,在二次線圈感應出電壓。比較以上三種接線,雙母線及雙母線帶旁路接線,供電可靠想高,任一回路開關(guān)故障或檢修,或任一回線故障或檢修,都不影響用戶用電,但是倒閘操作復雜,造價高,單母線分段接線,接線簡單,操作方便,便于擴建,在一定程度上也能提高供電可靠性,但是當一段母線上刀閘檢修時,該段母線上的全 部出線端都要長時停電,對于本所 35KV出線用戶均為一級,為保證對這些重要用戶得供電,采用雙母線接線方式。 適用范圍:適用于最終進出線為 3~5 回的 110kV及以上配電裝置。 d) 每回路有兩臺斷路器供電,任一臺斷路器檢修,不需中斷供電,也不需旁路設(shè)施。 ( 2) 調(diào)度靈活,當雙母線的兩組母線同時工作時,通過母線聯(lián)絡(luò)斷路器并聯(lián)運行,電源與負荷平均分配在兩組母線上。該接線具有可靠性高,運行靈活,節(jié)省占地等優(yōu)點。 ( 3) 短路電流計算和主要電器選擇 對選定的電氣主接線進行短路電流計算,并選擇合理的電氣設(shè)備。 ③ 負荷情況,包括負荷的性質(zhì)及其地理位置、輸電電壓等級、出線回路數(shù)及輸送容量等。 電氣主接線關(guān)系著全站電氣設(shè)備的選擇,配電裝置的布置繼電保護及自動裝置的確定,關(guān)系著電力系統(tǒng)的安全穩(wěn)定,靈活和經(jīng)濟運行,是本次變電站設(shè)計中心的主要環(huán)節(jié),我們在電氣主接線設(shè)計中,依據(jù)以下原則: ①保證必要的供電可靠性和電能質(zhì)量。 ( 3) 經(jīng)濟性 ① 投資省 a) 主接線應力求簡單,以節(jié)省斷路器、隔離開關(guān)、電流和電壓互感器。 ③ 盡量避免發(fā)電廠。 (4)繞 組連接方式的確定原則 我國 330kV 及以上電壓、變壓器都采用 Y。 ②對于 330 kV及以下的變電站,在設(shè)備運輸不受條件限制時,均采用三相變壓器。具體設(shè)計要綜合考慮 “ 每個設(shè)備的合理性、每個布置的合理性、每項改進的合理性、每個方案的合理性 ” 。 主要設(shè)計原則 變電站設(shè)計的原則是:安全可靠、技術(shù)領(lǐng)先、投資合理、標準統(tǒng)一、運行高效。這三個功能區(qū)即能相互獨立,又相互關(guān)聯(lián)和制約,不僅構(gòu)成了變電站總平面的基本模塊,也構(gòu)成模塊化設(shè)計的基本元素。 斷路器的選型:目前和將來很長一段時間內(nèi),瓷柱式斷路器、罐式斷路器、 HGIS、GIS、仍是主要的斷路器型式。示范變電站設(shè)計的成果及其應用和發(fā)展基本上代表了330kV 變電站的設(shè)計現(xiàn)狀,示范變電站設(shè)計的成果已經(jīng)廣泛用于近年來的工程建設(shè)當中,變電站設(shè)計已經(jīng)相當成熟。 總平面布置:從開始的一字型立環(huán)式布置開始也經(jīng)歷了很多演變, 20 世紀 80 年代開始基本上一直采用 330kV 配電裝置、主變壓器及抵低壓無功補償區(qū)和 110kV 配電裝置的三列式布置,所區(qū)占地面積也 有很大的下降。 330kV 變電站設(shè)計也相應經(jīng)歷了初期階段、成長階段和成熟階段。各個電壓等級分別采用 211 斷路器接線 、雙母線和 雙 母線的接線方式。 關(guān)鍵詞: 主變壓器、電氣主接線、 短路計算、繼電保護 ABSTRACT This design introduces a 330KV substation hubs throughout the design process, principles and methods. Transformers and wiring in the Main part of the main part of the content is the foundation, introduces the main connection in the form of an overview of the characteristics of different connection methods, their advantages and disadvantages and the principle of the transformer principle, according to mandate of the book chose to meet the design requirements The main task of wiring options. Shortcircuit current is a very important part, which introduces the purpose of calculating shortcircuit, principles, methods and specific data information for the design needs of the choice of high voltage electrical equipment, setting, checking and so to prepare. Selection and verification of electrical equipment is mainly employed symmetrical shortcircuit calculations for highvoltage electrical equipment (circuit breaker, disconnecting switch) validation. And protection of power configuration options, setting and calibration principles and methods. KEY WORDS: main transformer, main electrical wiring, relay, setting and calibration 目 錄 前 言 ..................................................................................................................................... 1 第 1 章 緒論 ......................................................................................................................... 2 設(shè)計的技術(shù)基礎(chǔ)和前提 ............................................................................................. 2 現(xiàn)行變電站設(shè)計的基本思路 ..................................................................................... 4 主要設(shè)計原則 ............................................................................................................. 4 第 2 章 主變壓器及電氣主接線的選擇 ............................................................................. 6 主變壓器的選擇 ......................................................................................................... 6 主變壓器型式及范圍 .......................................................................................... 6 變壓器型號的表示含義 ...................................................................................... 8 電氣主接線的選擇 ................................................................................................... 9 電氣主接線概念 .................................................................................................. 9 電氣主接線的基本要求 ...................................................................................... 9 設(shè)計步驟和內(nèi)容如下 ........................................................................................ 10 所選電氣主接線 .............................................................................................. 11 無功補償 ................................................................................................................... 15 第 3 章 短路電流計算 ....................................................................................................... 17 短路電流計算 ........................................................................................................... 17 短路電流和短路 容量 ............................................................................................... 17 短路電流將引起下列嚴重后果 ............................................................................... 17 限制短
點擊復制文檔內(nèi)容
公司管理相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1