freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

60kv變電站一次部分設(shè)計(jì)方案(存儲(chǔ)版)

2025-06-13 03:05上一頁面

下一頁面
  

【正文】 uce the flux.In general, it will be found that the transformer reacts almost instantaneously to keep the resultant core flux essentially constant. Moreover, the core flux φ0 drops very slightly between n o load and full load (about 1 to 3%), a necessary condition if Ep is to fall sufficiently to allow an increase in Ip.On the primary side, Ip’ is the current that flows in the primary to balance the demagnetizing effect of Is. Its MMF NpIp’ sets up a flux linking the primary only. Since the core flux φ0 remains constant. I0 must be the same current that energizes the transformer at no load. The primary current Ip is therefore the sum of the current Ip’ and I0.Because the noload current is relatively small, it is correct to assume that the primary ampereturns equal the secondary ampereturns, since it is under this condition that the core flux is essentially constant. Thus we will assume that I0 is negligible, as it is only a small ponent of the fullload current.When a current flows in the secondary winding, the resulting MMF (NsIs) creates a separate flux, apart from the flux φ0 produced by I0, which links the secondary winding only. This flux does no link with the primary winding and is therefore not a mutual flux.In addition, the load current that flows through the primary winding creates a flux that links with the primary winding only。變壓器是高效率的,因?yàn)樗鼪]有旋轉(zhuǎn)損失,因此在電壓等級(jí)轉(zhuǎn)換的過程中,能量損失比較少。3. 變壓器的工作原理當(dāng)二次側(cè)電路開路是,即使原邊被施以正弦電壓Vp,也是沒有能量轉(zhuǎn)移的。第二個(gè)分量Ie=I0sinθ0,與原邊電壓同相。因此,它于施加的電壓有180186。從交流電原理可知,有效值是一個(gè)正弦波,;因此E = 因?yàn)橐淮蝹?cè)繞組和二次側(cè)繞組的磁通相等,所以繞組中每匝的電壓也相同。為了計(jì)算電壓,我們需要更多數(shù)據(jù)。當(dāng)a=1時(shí),變壓器的二次側(cè)電壓就等于起一次側(cè)電壓。在上面公式中一次側(cè)和二次側(cè)的功率因素是相等的;因此VpIp = VsIs從上式我們可以得知 = ≌ ≌ a它表明端電壓比等于匝數(shù)比,換句話說,一次側(cè)和二次側(cè)電流比與匝數(shù)比成反比。產(chǎn)生電壓的平均值如下Eavg = turns即是法拉第定律在瞬時(shí)時(shí)間里的應(yīng)用。相同的磁通會(huì)通過原邊自身,產(chǎn)生一個(gè)電動(dòng)勢(shì)Ep。顯然可見電流分量Im= I0sinθ0,被稱做勵(lì)磁電流,它在相位上滯后于原邊電壓VP 90186。變壓器在原邊接收電能的同時(shí)也在向副邊所帶的負(fù)荷輸送電能。兩個(gè)線圈之所以相互耦合,是因?yàn)樗鼈冞B接著共同的磁通。 that is, it has no losses. ThusPm = PoutorVpIp primary PF = VsIs secondary PFwhere PF is the power factor. For the abovestated assumption it means that the power factor on primary and secondary sides are equal。 and (2) it provides a ponent to account for the hysteresis and eddy current losses in the core. There bined losses are normally referred to as the core losses.The noload current Iθ is usually few percent of the rated fullload current of the transformer (about 2 to 5%). Since at noload the primary winding acts as a large reactance due to the iron core, the noload current will lag the primary voltage by nearly 90186。此次設(shè)計(jì)能夠完成,首先我要感謝的是我的指導(dǎo)老師朱東柏老師?!敖Y(jié)論”以前的所有正文內(nèi)容都要編寫在此行之前。本設(shè)計(jì)中所選矩形母線為三相水平布置且平放,故W=bh2/6(mm2)只要母線滿足動(dòng)穩(wěn)定的條件: 即可認(rèn)為母線動(dòng)穩(wěn)定滿足校驗(yàn)。 單位長(zhǎng)度母線上所受相間電動(dòng)應(yīng)力(N/m);其可由下式求出: (722)式中 三相短路沖擊電流(A);相間距離;動(dòng)態(tài)應(yīng)力系數(shù)。經(jīng)過計(jì)算,母線初選為63,平放。母線起匯集和分配電能的作用。表712 避雷器的主要參數(shù)型號(hào)額定電壓有效值(kV)滅弧電壓有效值(kV)工頻放電電壓有效值(kV)沖擊放電電壓峰值()不大于(kV)8/20μ雷電沖擊波殘壓峰值不大于(kV)泄漏或電導(dǎo)電流(μA)不小于不大于5kA10kAFZ—6060140173220227250400~600FS—1010263150475010FZ60及FS10避雷器型號(hào)含義:F—閥型避雷器;Z—電站用;S—變電所用;60/10—額定電壓(kV)。兩種電流互感器的技術(shù)數(shù)據(jù)如下表所示:表711 LAJ10和LFZ110型電流互感器參數(shù)型號(hào)額定電壓(KV)額定變流比次級(jí)組準(zhǔn)確級(jí)10%倍數(shù)二次負(fù)荷1S熱穩(wěn)定倍數(shù)動(dòng)穩(wěn)倍數(shù)13LAJ10101000/50.5/D0.5101.25090LFZ11010200/50.5/B0.50.490160(2)動(dòng)穩(wěn)定校驗(yàn)型的電流互感器型的電流互感器故兩種電流互感器動(dòng)穩(wěn)定校驗(yàn)均合格。 10額定電壓(kV)。在高壓開關(guān)柜中或布置地位狹窄的地方,可采用樹脂澆注絕緣結(jié)構(gòu)。變壓器二次側(cè)計(jì)算數(shù)據(jù)與型斷路器技術(shù)數(shù)據(jù)比較如下表所示:表74斷路器計(jì)算數(shù)據(jù)比較表計(jì)算數(shù)據(jù)的參數(shù)經(jīng)表中數(shù)據(jù)比較可知,所選型斷路器滿足要求。在電力系統(tǒng)運(yùn)行中,對(duì)斷路器的要求是比較高的,不但要求其在正常工作條件下有足夠的接通和開斷負(fù)荷電流的能力,而且要求其在短路條件下,對(duì)短路電流有足夠的遮斷能力。故在設(shè)計(jì)中需要計(jì)算的是三相短路。最后是其他原因,例如挖溝損傷電纜、鳥獸或風(fēng)箏跨接在載流裸導(dǎo)體上等。從改變運(yùn)行方式靈活性來看,第二方案比第一方案投切變壓器時(shí),倒閘操作簡(jiǎn)便。第一種方案的特點(diǎn)如下:變壓器隨負(fù)荷變化投切方便;線路的投入和切除比較方便。根據(jù)實(shí)際情況選擇18臺(tái)型電容器。第4章 補(bǔ)償電容器的選擇系統(tǒng)無功平衡是一個(gè)重要的問題,為維持電壓水平就必須為負(fù)荷點(diǎn)提供一定的無功功率,如果負(fù)荷側(cè)的功率因數(shù)過低,會(huì)造成諸多不利影響:為此,當(dāng)系統(tǒng)功率因數(shù)過低的時(shí)候,應(yīng)增設(shè)無功補(bǔ)償設(shè)備來提高功率因數(shù),根據(jù)《全國(guó)供電規(guī)則》規(guī)定“,這與本次設(shè)計(jì)任務(wù)要求相一致。(4)在確定變電所主變壓器參數(shù)時(shí),應(yīng)適當(dāng)考慮負(fù)荷的發(fā)展,留有一定的余地。確定合理的變壓器容量是變電所安全可靠供電和網(wǎng)絡(luò)經(jīng)濟(jì)運(yùn)行的保證。查《電力工程電氣設(shè)計(jì)手冊(cè)》411頁,附表84:LGJ鋼芯鋁絞線規(guī)格及長(zhǎng)期允許載流量,選用型架空線,其參數(shù)為:。導(dǎo)線截面選擇過大,會(huì)增加線路的投資,導(dǎo)線截面過小,會(huì)增加導(dǎo)線運(yùn)行中電壓和電能損耗,使電能傳輸質(zhì)量和運(yùn)行的經(jīng)濟(jì)性變差,所以要選擇合適的導(dǎo)線截面。經(jīng)濟(jì)性:綜合考慮工程初期投資與長(zhǎng)期運(yùn)行費(fèi)用,追求工程壽命期內(nèi)最佳的企業(yè)經(jīng)濟(jì)效益。電氣主接線是發(fā)電廠變電所的主要環(huán)節(jié),電氣主接線的擬定直接關(guān)系著全所電氣設(shè)備的選擇、配電裝置的布置、繼電保護(hù)和自動(dòng)裝置的確定,是變電站電氣部分投資大小的決定性因素。典型設(shè)計(jì)是對(duì)以往電網(wǎng)設(shè)計(jì)經(jīng)驗(yàn)的總結(jié)和提高;是多快好省建設(shè)電網(wǎng)的必由之路;是全面貫徹落實(shí)黨的十六屆五中全會(huì)精神,落實(shí)科學(xué)發(fā)展觀,建設(shè)“資源節(jié)約型、環(huán)境友好型”社會(huì),大力提高集成創(chuàng)新能力的重要體現(xiàn)。通過建設(shè)以特高壓電網(wǎng)為核心的堅(jiān)強(qiáng)的國(guó)家電網(wǎng),實(shí)現(xiàn)跨地區(qū)、跨流域水貨互濟(jì),將清潔的電能從西部和北部大規(guī)模輸送到中東部地區(qū),這是解決我國(guó)能源和電力供應(yīng)問題的有效途徑,這是解決我國(guó)能源和電力供應(yīng)問題的有效途徑,是優(yōu)化資源配置方式,提高資源配置效率,保障國(guó)家能源安全的戰(zhàn)略舉措。這種能源分布與消費(fèi)的不平衡狀況,決定了能源資源必須在全國(guó)范圍內(nèi)優(yōu)化配置,必須以大煤電基地、大水電基地為依托,實(shí)現(xiàn)煤電就地轉(zhuǎn)換和水電大規(guī)模開發(fā)。必須大力推廣典型設(shè)計(jì)。隨著國(guó)民經(jīng)濟(jì)的發(fā)展,工農(nóng)業(yè)生產(chǎn)的增長(zhǎng)需要,迫切要求增長(zhǎng)供電容量,擬新建66kV變電所。先進(jìn)性:推廣應(yīng)用電網(wǎng)新技術(shù),鼓勵(lì)設(shè)計(jì)創(chuàng)新;典型設(shè)計(jì)各項(xiàng)技術(shù)經(jīng)濟(jì)可比指標(biāo)先進(jìn)。因此本變電所的架空線路采用鋼芯鋁絞線,符號(hào):LGJ—**,其中**為導(dǎo)線的標(biāo)稱截面(mm2)。 式中 S——導(dǎo)線經(jīng)濟(jì)截面(mm2); ——線路正常運(yùn)行時(shí)的最大負(fù)荷電流(A);J——經(jīng)濟(jì)電流密度(A/mm2),可根據(jù)經(jīng)濟(jì)電流密度曲線查取。 線路功率損耗計(jì)算阻抗損耗: 導(dǎo)納損耗:,型導(dǎo)線的電納為: , 則機(jī)械制造廠的線路損耗為: 同理,可以求出針織器材廠,織布廠,標(biāo)準(zhǔn)件廠,服裝廠,糧食加工場(chǎng),汽水廠,化工廠各部分技術(shù)參數(shù),如下表則綜上10KV線路所選架空線參數(shù)如下表所示:表21 10KV線路架空線參數(shù)序號(hào)負(fù)荷名稱線路狀況型號(hào)經(jīng)濟(jì)密度電阻值電抗值回?cái)?shù)長(zhǎng)度1機(jī)械制造廠232針織器材廠243織布廠154標(biāo)準(zhǔn)件廠265服裝廠186糧食加工廠187汽水廠158化工廠22第3章 選擇主變壓器的臺(tái)數(shù)、容量、型號(hào)在各級(jí)電壓等級(jí)的變電所中,變壓器是主要電氣設(shè)備之一,其擔(dān)負(fù)著變換網(wǎng)絡(luò)電壓進(jìn)行電力傳輸?shù)闹匾蝿?wù)。(3)對(duì)于集中負(fù)荷較大的情況,雖為三級(jí)負(fù)荷,也應(yīng)采用兩臺(tái)及以上的變壓器。主變壓器主要參數(shù)見下表:表31 SF9—12500/60型有載調(diào)壓變壓器參數(shù)型號(hào)額定容量(kVA)電壓組合聯(lián)接組別空載損耗(W)負(fù)載損耗(W)空載電流(%)阻抗電壓(%)尺寸(mm)軌距(mm)高壓(kV)分接范圍低壓(kV)長(zhǎng)寬高SF912500/601250060+8%10YN,d11168005985095400373047201475(2)SF9—12500/60其型號(hào)含義說明如下:S三相電力變壓器;F冷卻方式風(fēng)冷式;9設(shè)計(jì)序號(hào);60高壓繞組電壓等級(jí)(kV); 12500額定容量(kVA)。其技術(shù)參數(shù)如下表所示:表41 BWF2001W電容器的技術(shù)參數(shù)型號(hào)規(guī)格額定電壓(kV)標(biāo)稱容量(KVar)標(biāo)稱電容μF相數(shù)外形尺寸長(zhǎng)*寬*高(mm)重量kgBWF—200—1W2001700*174*1010120則所需電容器臺(tái)數(shù)為:臺(tái)式中 計(jì)算補(bǔ)償容量(KVar); 每臺(tái)電容器的標(biāo)稱容量(KVar)。 圖5
點(diǎn)擊復(fù)制文檔內(nèi)容
公司管理相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1