【正文】
ND X004 399 OUT T5 K100 402 MRD 403 AND Y005 404 AND X005 405 OUT T6 K100 408 MRD 409 AND T6 410 OUT T7 K30 413 AND T7 414 AND X011 415 AND X014 416 OUT S20 418 MRD 419 LD X000 420 ANI Y005 421 OR T4 422 OR T13 423 ANB 424 AND X013 425 AND X016 426 SET S22 428 MRD 429 ANI X000 430 ANI Y001431 MPS432 AND Y005 433 OUT T8 K60 436 OUT T15 K90 439 MPP 440 RST Y004 441 ZRST Y006 Y010 446 ANI T8 447 OUT Y000 448 MPP 449 LD T15 450 OR M32 451 OR Y001 452 ANB 453 OUT S0 455 LD S22 456 MPS 457 AND X013 458 AND X016 459 MPS 460 ANI Y005 461 AND X000 462 MPS 463 AND X012 464 AND X015 465 OUT Y006 466 MPP 467 AND X011 468 AND X014 469 OUT Y004 470 MRD 471 ANI Y010 472 OUT Y007473 MRD 474 AND Y007 475 OUT T11 K60 478 MRD 479 LDI X012 480 ORI X015 481 ANB 482 AND X000 483 OUT T17 K5 486 MPP 487 LD T11 488 OR T17 489 ANB 490 ANI T8 491 OUT Y012 492 MRD 493 AND Y007 494 AND X005 495 OUT T2 K100 498 MRD 499 AND T7 500 MPS 501 AND X012 502 AND X015 503 OUT S21 505 MPP 506 LDI X012 507 ORI X015 508 ANB 509 AND X011 510 AND X014 511 OUT S20513 MRD 514 ANI X000 515 ANI Y001 516 MPS 517 AND Y007 518 OUT T8 K60 521 OUT T15 K90 524 MPP 525 ZRST Y003 Y006 530 RST Y010 531 ANI T8 532 OUT Y000 533 MPP 534 LD T15 535 OR M32 536 OR Y001 537 ANB 538 OUT S0 540 LD S30 541 ZRST Y006 Y010 546 MPS 547 AND X012 548 AND X015 549 MPS 550 ANI Y006 551 SET Y005 552 MPP 553 OUT T12 K2 556 AND T12 557 ANI T8 558 OUT Y012559 MRD560 AND Y012561 AND X004 562 OUT T4 K100 565 MRD 566 LDI X012 567 ORI X015 568 ANB 569 RST Y0。在此,向指導(dǎo)和幫助過(guò)我的老師表示最真心的感謝!感謝這篇論文所涉及到的各位學(xué)者提供的研究文獻(xiàn),如果沒(méi)有各位學(xué)者的研究成果的幫助和啟發(fā),我將很難完成本篇論文的寫作。針對(duì)多臺(tái)氣泵共同運(yùn)作是產(chǎn)生的散熱問(wèn)題,可以在氣泵旁邊安裝散熱風(fēng)扇,當(dāng)多臺(tái)氣泵一起運(yùn)轉(zhuǎn)時(shí)啟動(dòng)散熱風(fēng)扇,可以達(dá)到降溫的效果。本課題設(shè)計(jì)的YJF60型負(fù)壓抽吸系統(tǒng)還存在一定的不足。若在正常壓力范圍時(shí)卸荷電磁閥不工作,當(dāng)抽吸壓力達(dá)到超過(guò)設(shè)定值時(shí),卸荷閥動(dòng)作排氣,使壓力控制在正常壓力范圍內(nèi)。在整個(gè)系統(tǒng)模擬調(diào)試過(guò)程中,總會(huì)出現(xiàn)各種各樣的問(wèn)題和困難。經(jīng)過(guò)分析,發(fā)現(xiàn)狀態(tài)指令S20段程序出現(xiàn)了邏輯上的錯(cuò)誤,經(jīng)過(guò)修改,才能運(yùn)行正常。程序編寫使用FX2N格式編寫的,而PLC是FX1S系列,所以將程序格式轉(zhuǎn)換為FX1S后才能成功將程序?qū)懭隤LC中。說(shuō)明本課題設(shè)計(jì)模擬調(diào)試獲得成功。合上X2,此時(shí)監(jiān)視狀態(tài)下的X2呈現(xiàn)綠色狀態(tài),說(shuō)明液位已經(jīng)到達(dá)中液位限位開(kāi)關(guān),此時(shí)驅(qū)動(dòng)了Y11,廢水泵起動(dòng),開(kāi)始排水。再模擬2氣泵損壞,按下按鈕X12,此時(shí)程序段從S21跳轉(zhuǎn)到S22,此時(shí)驅(qū)動(dòng)了Y7,驅(qū)動(dòng)了Y12,這時(shí)候3氣泵變頻起動(dòng)。⑷ 合上 X0,監(jiān)視狀態(tài)下的X0呈現(xiàn)綠色,說(shuō)明系統(tǒng)已經(jīng)開(kāi)始正常運(yùn)行。用事先編寫好的試驗(yàn)程序作掃描通電檢查來(lái)查找接線故障?! ≡谡{(diào)試時(shí)應(yīng)充分考慮各種可能的情況,對(duì)系統(tǒng)各種不同的工作方式、有選擇序列的功能表圖中的每一條支路、各種可能的進(jìn)展路線,都應(yīng)逐一檢查,不能遺漏。將設(shè)計(jì)好的程序?qū)懭隤LC后,首先逐條仔細(xì)檢查,并改正寫入時(shí)出現(xiàn)的錯(cuò)誤。⑵ 在仿真環(huán)境下對(duì)plc軟件進(jìn)行完備的校驗(yàn),測(cè)試和優(yōu)化,顯著提高工程的質(zhì)量和可靠性。5. 系統(tǒng)調(diào)試為了測(cè)試設(shè)計(jì)的負(fù)壓抽吸系統(tǒng)是否滿足工藝要求,需要對(duì)系統(tǒng)進(jìn)行調(diào)試,從而發(fā)現(xiàn)問(wèn)題,分析問(wèn)題,解決問(wèn)題。當(dāng)氣液分離罐經(jīng)清洗后,廢水泵運(yùn)行將飛回排出。C30驅(qū)動(dòng)Y2,使清洗電磁閥動(dòng)作。S30用于控制氣泵起動(dòng)順序中的231起動(dòng)序列,原理和S20相似。當(dāng)系統(tǒng)發(fā)生報(bào)警時(shí),整體復(fù)位三臺(tái)氣泵。S30~S40同S20處理。,且持續(xù)10秒,則停止抽吸氣泵的運(yùn)行,并發(fā)出報(bào)警信號(hào)。②當(dāng)氣液分離罐在清洗狀態(tài),氣液分離罐廢水液位達(dá)到中液位,延時(shí)15秒后廢水泵運(yùn)行,當(dāng)液位低于低液位時(shí),延時(shí)5秒后廢水泵停止。以上是1氣泵受變頻器起動(dòng)的動(dòng)作過(guò)程,2氣泵和3氣泵受變頻器起動(dòng)的動(dòng)作過(guò)程和1氣泵類似,就不一一例舉了。停止第三臺(tái)氣泵的接觸器KM3,使第三臺(tái)氣泵停止運(yùn)行。變頻器根據(jù)接收的電流信號(hào)調(diào)整變頻器的輸出電壓與頻率,改變1氣泵電動(dòng)機(jī)的轉(zhuǎn)速,保證抽吸負(fù)壓的穩(wěn)定(例穩(wěn)定在14KPa)。重新接通變頻器的起動(dòng)信號(hào)Y3, 變頻器根據(jù)接收的電流信號(hào)調(diào)整變頻器的輸出電壓與頻率,改變1氣泵電動(dòng)機(jī)的轉(zhuǎn)速,保證抽吸負(fù)壓的穩(wěn)定(例穩(wěn)定在14KPa)。當(dāng)PLC接收到來(lái)自牙科治療椅的起動(dòng)信號(hào)(無(wú)源開(kāi)關(guān)量信號(hào)),PLC發(fā)出控制受變頻器驅(qū)動(dòng)1氣泵M1的接觸器KM1接通信號(hào),受變頻器驅(qū)動(dòng)的1氣泵M1起動(dòng),受變頻器驅(qū)動(dòng)的1氣泵M1起動(dòng)后,根據(jù)壓力傳感器采集的壓力信號(hào),壓力傳感器對(duì)變頻器及壓力顯示控制器發(fā)出相應(yīng)的電流信號(hào)(30KPa對(duì)應(yīng)的電流為4mA DC 0KPa對(duì)應(yīng)的電流為20mA DC),壓力顯示控制器顯示抽吸壓力。變頻起動(dòng)由變頻器MM430控制。再根據(jù)工作流程圖,分析系統(tǒng)各個(gè)板塊的工作過(guò)程。 程序段對(duì)應(yīng)氣泵起動(dòng)順序表受變頻器控制的氣泵第二臺(tái)運(yùn)行氣泵第三臺(tái)運(yùn)行氣泵S20,S21,S22M1M2M3S30,S31,S32M2M3M1S40,S41,S42M3M1M2 系統(tǒng)工作流程圖 PLC端口分配X、Y分別表示PLC的輸入/輸出信號(hào)。 系統(tǒng)的電器工藝圖 4. 程序設(shè)計(jì)及分析YJF60型負(fù)壓抽吸系統(tǒng)的過(guò)程控制主要包括四個(gè)板塊:抽吸氣泵控制設(shè)計(jì)、廢水泵控制設(shè)計(jì)、清洗進(jìn)水閥控制設(shè)計(jì)、卸荷閥控制設(shè)計(jì)。相序繼電器的外尺寸是4570。電氣元件可方便地卡在導(dǎo)軌上而無(wú)需用螺絲固定,維護(hù)也很方便。5 熔斷器的繪制()。接觸器的外形尺寸是44mm80mm,有3對(duì)主觸點(diǎn)和一對(duì)輔助觸點(diǎn)。9是公共點(diǎn),5是常開(kāi)點(diǎn),1是常閉點(diǎn)。FX1S30MR的外形尺寸大小為100mm90mm,它的輸入輸出為8進(jìn)制編號(hào),有X0~X16一共16個(gè)輸入端,Y0~Y15一共14個(gè)輸出端。AC220V/3A;DC24V/6A(阻性負(fù)載)可控硅控制輸出-SCR(可控硅過(guò)零觸發(fā)脈沖)輸出,DC 15V(負(fù)載電阻≤250KΩ)開(kāi)關(guān)量輸出壓力變送器SMP131的壓力測(cè)量范圍是0~,1bar=100KPa,所以40KPa=,可以滿足設(shè)計(jì)要求,所以選用SMP131S4M1F2D()。本課題設(shè)計(jì)中,已經(jīng)算出氣泵的Ijs=,選用西門子3TB40接觸器(),它的額定電流為9A,可以滿足條件,它的外形尺寸是44mm80mm。本課題設(shè)計(jì)中繼電器用于卸荷閥和進(jìn)水閥中,這些電磁閥P=160W,U=220V,MY2NJ 5A 220AC,所以選用歐姆龍MY2NJ繼電器()可以滿足設(shè)計(jì)條件。40A額定電壓(AC25A16A所以決定選用施耐德的梅蘭日蘭C65 3P 10A空氣開(kāi)關(guān)(),它的外形尺寸是55mm81mm。 三組參數(shù)切換功能:電機(jī)數(shù)據(jù)切換,命令數(shù)據(jù)切換; 西門子MM430變頻器圖⑶ 空氣開(kāi)關(guān)的選擇:空氣開(kāi)關(guān)具有控制和多種保護(hù)功能于一身。 具有15個(gè)固定頻率,4個(gè)跳轉(zhuǎn)頻率,可編程; 牢固的EMC(電磁兼容性)設(shè)計(jì); 控制信號(hào)的快速響應(yīng) MM430主要參數(shù)表本課題設(shè)計(jì)的YJF60負(fù)壓抽吸系統(tǒng)的負(fù)載類型為風(fēng)機(jī)泵類負(fù)載,三臺(tái)氣泵都是可以變頻起動(dòng),要求功率較大,計(jì)算氣泵的Ijs來(lái)確定變頻器的型號(hào)選擇。PLC機(jī)型的選擇PLC機(jī)型選擇的基本原則是在滿足功能要求及保證可靠、維護(hù)方便的前提下,力爭(zhēng)最佳的性能價(jià)格比。 ⑷盡量減少通電電器的數(shù)目,以利節(jié)能與延長(zhǎng)電器元件壽命,減少故障。在設(shè)計(jì)電器工藝圖過(guò)程中,需要遵循以下原則:⑴盡量縮短連接導(dǎo)線的長(zhǎng)度和導(dǎo)線數(shù)量,設(shè)計(jì)控制電路時(shí),應(yīng)考慮各電器元件的安裝位置,盡可能地減少連接導(dǎo)線的數(shù)量,縮短連接