110kv變電站電氣一次部分設(shè)計(jì)畢業(yè)論文正文-全文預(yù)覽

  

【正文】 dissimilar, concrete choice method quite same not less than, but all has the unanimous request to them, the electrical equipment must be able the reliable work, must carry on the choice according to the regular service condition, and according to shortcircuits the condition to verify the thermally stable and to move stably. The power distribution equipment is according to the electrical host wiring connection way, by the switch electric appliance, the protection and the survey electric appliance, the generator and the essential supporting facility sets up the overall installment which but bees. By this design looked 110KV suitably uses outdoor form, 35KV and 10KV suitably uses in the room the form. In order to prevent with the limit thunder and lightning hazardous 范文范例參考 WORD 格式整理 nature, in the transformer substation also should use the antiradar measure and the antiradar protective device.Key words: circuit breaker disconnect switch switchyard lightning arrester 目 錄前 言 ......................................................................................................11 電力系統(tǒng)概述 ....................................................................................3 電力系統(tǒng)分析 .........................................................................3 變電站總體分析 .....................................................................5 建設(shè)規(guī)模 ......................................................................5 范文范例參考 WORD 格式整理 選址概況 ......................................................................5 負(fù)荷分析 .................................................................................52 主變壓器的選擇 ................................................................................8 主變?nèi)萘窟x擇應(yīng)考慮問(wèn)題 .....................................................8 主變額定容量的選擇計(jì)算 .....................................................8 變壓器相數(shù)的形式的選擇 .....................................................9 變壓器相數(shù)的選擇 ......................................................9 繞組數(shù)和繞組連接方式的選擇 ..................................9 主變阻抗和調(diào)壓方式的選擇 ....................................10 容量比 ........................................................................10 變壓器各側(cè)電壓的選擇 ............................................103 電氣主接線設(shè)計(jì) ..............................................................................11 電氣主接線設(shè)計(jì) ...................................................................11 主接線設(shè)計(jì)應(yīng)該考慮的基本問(wèn)題 .......................................11 主接線的設(shè)計(jì)步驟 ................................................................12 110V 電壓等級(jí)接線方式的確定 .............................12 35KV 電壓等級(jí)主接線的分析設(shè)計(jì) .......................13 10KV 電壓等級(jí)主接線的確定 ...............................144 短路電流的計(jì)算 ..............................................................................16 選擇基準(zhǔn)容量 .......................................................................16 計(jì)算各線路電抗 ...................................................................17 對(duì)應(yīng)的標(biāo)幺值 .......................................................................17 系統(tǒng)電抗 ...............................................................................17 各電壓側(cè)計(jì)算 .......................................................................185 電氣設(shè)備的選擇 ..............................................................................24 電器選擇 ...............................................................................24 導(dǎo)體和絕緣子 ............................................................24 電氣設(shè)備 ....................................................................24 選擇導(dǎo)體和電器設(shè)備的技術(shù)條件 .......................................24 母線選擇和負(fù)荷出線選擇的計(jì)算過(guò)程 ...............................25 110KV 母線選擇 ......................................................25 110KV 側(cè)主變引下線 ..............................................26 35KV 母線發(fā)熱及 穩(wěn)定性較驗(yàn)計(jì)算書(shū) ....................27 35KV 側(cè)主變引下線的計(jì)算 .......................................28 10KV 側(cè)電氣計(jì)算書(shū) ...................................................29 10KV 側(cè)主變引下線的計(jì)算 ....................................30 范文范例參考 WORD 格式整理 電氣設(shè)備的選擇 .................................................................31 斷路器選擇和隔離開(kāi)關(guān)的選擇 ................................31 110KV 側(cè)計(jì)算書(shū) ......................................................32 35KV 側(cè)計(jì)算書(shū) ...........................................................33 10KV 側(cè)計(jì)算書(shū) ...........................................................34 電壓互感器和電流互感器的選擇 .......................................386 配電裝置設(shè)計(jì) ...................................................................................40 配電裝置設(shè)計(jì) .......................................................................40 配電裝置概述 ............................................................40. 配電裝置設(shè)計(jì)原則 ...................................................40 配電裝置型式選擇 ....................................................40. 各電壓等級(jí)配電裝置設(shè)計(jì) .......................................41 35KV 及 10KV 配電裝置設(shè)備列表 ...........................427 防雷保護(hù) ........................................................................................44 變電所的直擊雷保護(hù) ...........................................................44 雷電過(guò)電壓波的防護(hù) ...........................................................45總 結(jié) ....................................................................................................47致 謝 ....................................................................................................48參考文獻(xiàn) ..............................................................................................49 范文范例參考 WORD 格式整理 前 言變電站是電力系統(tǒng)中不可缺少的重要環(huán)節(jié),對(duì)電網(wǎng)的安全和經(jīng)濟(jì)運(yùn)行起著舉足輕重的作用,如果仍然依靠原來(lái)的人工抄表、記錄、人工操作為主,將無(wú)法滿足現(xiàn)代電力系統(tǒng)管理模式的需求;同時(shí)用于變電站的監(jiān)視、控制、保護(hù),包括故障錄波、緊急控制裝置,不能充分利用微機(jī)數(shù)據(jù)處理的大功能和速度,經(jīng)濟(jì)上也是一種資源浪費(fèi)。因此,變電站自動(dòng)化既是實(shí)現(xiàn)自動(dòng)化的重要基礎(chǔ)之一,也是滿足現(xiàn)代化供用電的實(shí)時(shí),可靠,安全,經(jīng)濟(jì)運(yùn)行管理的需要,更是電力系統(tǒng)自動(dòng)化 EMS 和 DMS 的基礎(chǔ)。電力系
點(diǎn)擊復(fù)制文檔內(nèi)容
范文總結(jié)相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1