【正文】
a flux that links with the primary winding only。 that is, it has no losses. Thus Pm = Pout or VpIp primary PF = VsIs secondary PF where PF is the power factor. For the abovestated assumption it means that the power factor on primary and secondary sides are equal。, therefore, they are 180186。 and (2) it provides a ponent to account for the hysteresis and eddy current losses in the core. There bined losses are 鄭州大學(xué)電氣工程學(xué)院畢業(yè)論文 8 normally referred to as the core losses. The noload current Iθ is usually few percent of the rated fullload current of the transformer (about 2 to 5%). Since at noload the primary winding acts as a large reactance due to the iron core, the noload current will lag the primary voltage by nearly 90186。這證明了它對我們分析變壓器時所產(chǎn)生的影響微乎其微。另外,兩側(cè)繞組同樣具有阻抗,這也將產(chǎn)生一個電阻壓降。 另外,流過一次側(cè)繞組的負(fù)載電流只在一次側(cè)繞組中產(chǎn)生磁通,這個磁通被稱為一次側(cè)的漏磁。因?yàn)樵谶@種狀況下鐵芯的磁通是恒定的。它的磁動勢 NpIp’只停鄭州大學(xué)電氣工程學(xué)院畢業(yè)論文 6 留在一次側(cè)。 總的來說,變 壓器為了保持磁通是常數(shù),對磁通變化的響應(yīng)是瞬時的。因此, NsIs 所產(chǎn)生的磁動勢會使主磁通 φ0減小。當(dāng)變壓器帶負(fù)荷運(yùn)行時,將有電流 Is 流過二次側(cè),因?yàn)?Es 產(chǎn)生的感應(yīng)電動勢相當(dāng) 于一個電壓源。如果點(diǎn)號同在線圈的上端,就意味著它們的極性相同。根據(jù) Vs 和 Is,可得 Vp 和 Ip 的比例是 ppVI = /ssaVIa = 2ssaVI 但是 Vs / Is 負(fù)荷阻抗 ZL,因此我們可以這樣表示 Zm (primary) = a2ZL 這個等式表明二次側(cè)連接的阻抗折算到電源側(cè),其值為原來的 a2 倍。 顯然,鐵芯中的電磁通形成了連接原邊和副邊的回路。在一個降壓變壓器中傳輸變比 a 遠(yuǎn)大于 1(a),同樣的,一個升壓變壓器的變比小于 1(a)。 終端電壓的比率變化有些根據(jù) 負(fù) 載和它的功率因素。因此 Pm = Pout 或者 VpIp primary PF = VsIs secondary PF 這里 PF 代表功率因素。因此 Ep = 并且 Es = 其中 Np 和 Es 是一次側(cè)繞組和二次側(cè)繞組的匝數(shù)。原邊的電壓和它產(chǎn)生的磁通波形是正弦形的;因此鄭州大學(xué)電氣工程學(xué)院畢業(yè)論文 4 產(chǎn)生電動勢 Ep 和 Es 的值是做正弦變化的。的相位差。因?yàn)橐淮蝹?cè)繞組中的磁通會通過二次繞組,依據(jù)法拉第電磁感應(yīng)定律,二次側(cè)繞組中將產(chǎn)生一個電動勢 E,即 E=NΔφ/Δt。這個電流分量向鐵芯提供用于損耗的電流。因?yàn)樵诳蛰d時,原邊繞組中的鐵芯相當(dāng)于一個很大的電抗,空載電流的相位大約將滯后于原邊電壓相位 90186。外加電壓在一次側(cè)繞組中產(chǎn)生一個小電流 Iθ。磁通是變化的;因此依據(jù)楞次定律,電磁感應(yīng)在二次側(cè)產(chǎn)生了電壓。典型的效率范圍 在 92 到 99%, 上限值適用于大功率變壓器。 2. 雙繞組變壓器 變壓器的最簡單形式包括兩個磁通相互耦合的固定線圈。 附錄 1:外文資料翻譯 譯文 變壓 器 1. 介紹 要從遠(yuǎn)端發(fā)電廠送出電能,必須應(yīng)用高壓輸電。 There are nine drawings total, in which four are prepared by hand, others are prepared by puter in which installed the software electrical AutoCAD. From other view, it also can be classified as first part and second part. This is a design of substation for graduation design test. It can strengthen our specified knowledge. Keywords: Ⅰ substation Ⅱ transformer Ⅲ Relay protection 謝 辭 首先, 在設(shè)計前的理論學(xué)習(xí)和實(shí)驗(yàn)環(huán)節(jié) 中,劉憲林、王 克文、陳根永、孔斌、包毅等專業(yè)課和實(shí)驗(yàn)指導(dǎo)老師的教導(dǎo)為我提供了豐富的專業(yè)理論知識和實(shí)踐分析能力。通過本次設(shè)計,使我對電氣工程及其自動化專業(yè)的主干課程有一個較為全面,系統(tǒng)的掌握,增強(qiáng)了理論聯(lián)系實(shí)際的能力,提高了工程意識,鍛煉了我獨(dú)立分析和解決電力工程設(shè)計問題的能力,為未來的實(shí)際工作奠定了必要的基礎(chǔ)。母線保護(hù)和所用變保護(hù)設(shè)計。 說明書和計算書包括整體概述 。電氣設(shè)備選擇 。 一次部分由說明書,計算書與電氣工程圖組成,說明書和計算書包括變電所總體分析 。其設(shè)計分為電氣一次部分和電氣二次部分設(shè)計。短路電流計算 。 二次部分由說明書,計算書與電氣工程圖組成 。電容器的保護(hù)整定計算 。 本變電所設(shè)計為畢業(yè)設(shè)計課題,以鞏固大學(xué)所學(xué)知識。 Specifications and putation book include following section: General, The evaluation and calculate of line protection, Transformer protection, capacitor protection, Bus protection and Selfusing transformer protection. Computation book, Electrical engineering drawings and catalogue of drawings are attached in the end。 設(shè)計中雖 然 充分采納了老師和同學(xué)們的意見,幾經(jīng)修改,但由于是初次設(shè)計,加之自身水平有限, 設(shè)計及論述過程中難免有錯誤, 請 各位老師批評指正。本文我XXX: XF110KV 變電所設(shè)計 3 們討論的原則和電力變壓器的應(yīng)用。 變壓器 是 高效率的 ,因?yàn)樗鼪]有旋轉(zhuǎn)損失, 因此 在電壓等級轉(zhuǎn)換的過程中,能量損失比較少 。磁通連接的第二個繞組被稱為變壓器的二次側(cè)繞組或者是副邊。 3. 變壓器的工作原理 當(dāng)二次側(cè)電路開路是,即使原邊被施以正弦電壓 Vp,也是沒有能量轉(zhuǎn)移的。 變壓器空載電流 Iθ 一般大約只有滿載電流的 2%— 5%。 第二個分量 Ie=I0sinθ0, 與原邊電壓同相。 如果假定變壓器中沒有其他的電能損耗一次側(cè)的感應(yīng)電動勢 Ep 和二次側(cè)的感應(yīng)電壓 Es 可以表示出來。因此,它于施加的電壓有 180186。因此原邊電壓很小,并且 Vp 的值近乎等于 Ep。從交流電原理可知,有效值是 一個正弦波,其值為平均電壓的 倍;因此 E = 因?yàn)橐淮蝹?cè)繞組和二次側(cè)繞組的磁通相等,所以繞組中每匝的電壓也相同。實(shí)際上我們是考慮一臺理想 狀態(tài)下的變壓器;這意味著它沒有任何損耗。為了計算電壓,我們需要更多數(shù)據(jù)。如果這個電壓是升高的,它就是一個升壓變壓器。因此,我們把這種類型的變壓器稱為絕緣型變壓器。從等式 psVV = psII ≌ psEE ≌ a 中我們可知 Vp = aVs 并且 Ip = Is/a。