freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

酒店管理會(huì)所8皇冠酒店設(shè)計(jì)標(biāo)準(zhǔn)手冊(cè)建筑消防安全doc(最新整理)(文件)

 

【正文】 security and strength of the installation and to ensure ease of operation for the guest. This device may be a safety bar/chain or other nonkeyed locking device and must be approved by IHG Design amp。 ? 16mm throw deadlocking latch set with an antipanic feature whereby the deadbolt releases upon activation of the door lever on the guestroom side of door 16mm 長(zhǎng)鎖舌的鎖定閂,帶有緊急逃生設(shè)置,轉(zhuǎn)動(dòng)房間內(nèi)側(cè)門(mén)把手可以直接將鎖舌收回。 (j) All kitchen area doors will be minimum 30 minutes fire resisting and a minimum of 900mm wide. They will be selfclosing with view window, kick and push plates 所有廚房區(qū)域的門(mén)至少要求有 30 分鐘防火時(shí)間, 且最小寬度為 900mm。垃圾滑槽末端的門(mén),可以在設(shè)有熔斷裝置的情況下保持開(kāi)啟。圖表上的信息由英文書(shū)寫(xiě),根據(jù)酒店所處地區(qū),至少寫(xiě)有第二種合適的語(yǔ)言。 (d) All fireresisting doors will have approved selfclosing devices. Where these doors need to be held open, magic release devices that are linked to the fire alarm system must be used. 所有防火門(mén)都必須裝有自動(dòng)關(guān)閉裝置。 (b) Doors within a building constructed to achieve 60 minutes structural fire 皇冠酒店設(shè)計(jì)標(biāo)準(zhǔn)手冊(cè) 10 葉予舜 12/19/2020 7:32:55 PM protection, along with doors to storage rooms, plant rooms and plumbing shaft doors where the shaft is horizontally fire stopped at each level, will have 30 minutes fire resistance. 要求達(dá)到 60 分鐘防火等級(jí)的建筑物內(nèi)的門(mén),以及通向儲(chǔ)藏室、花草室、以及在每一樓層水平方向已阻火的管線井門(mén),防火等級(jí)為 60 分鐘。警示語(yǔ)為英語(yǔ)書(shū)寫(xiě),以及根據(jù)酒店所處地區(qū),至少還需由第二種合適的語(yǔ)言書(shū)寫(xiě)。 (x) Wood frame construction buildings with two floors or more to be provided with sprinkler protection 兩層樓以上的木框架建筑,必須安裝消防噴淋保護(hù)設(shè)施。 (u) All guestroom doors to be selfclosing and latching. No hold open mechanism allowed 所有客房門(mén)必須自動(dòng)關(guān)閉并上鎖。 (o) Fire rating of 2hours is required if building structure (highest inhabitable floor level) is more than 25M above grade level or fire department access level 如若建筑結(jié)構(gòu)(最高居住樓層)超過(guò) 25 米樓層或消防可至樓層,要求設(shè)有 2 小時(shí)防火等級(jí)。 皇冠酒店設(shè)計(jì)標(biāo)準(zhǔn)手冊(cè) 7 葉予舜 12/19/2020 7:32:55 PM (k) No bustible material installed/stored in exit stairs 逃生樓梯處 ,不得安裝 / 儲(chǔ)存可燃材料。 (g) Illuminated exits signs with a secondary source of power placed so that the exit from the building is clearly marked 應(yīng)妥善設(shè)置帶有第二電源供電的發(fā)光出口標(biāo)牌,以使建筑內(nèi)的安全出口能夠清楚地標(biāo)示。(不得采用電池供電的煙感探測(cè)器) (b) All other habitable areas of the hotel provided with a smoke detection system 皇冠酒店設(shè)計(jì)標(biāo)準(zhǔn)手冊(cè) 6 葉予舜 12/19/2020 7:32:55 PM connected to a central alarm panel 酒店內(nèi)所有其它居住區(qū)域,都需安裝連接到中央報(bào)警面板的煙感探測(cè)系統(tǒng) (c) Activation of an alarm sounds an alarm on the floor of origin, at the constantly attended alarm panel and all areas immediately exposed to the fire 火警時(shí), 在起火的樓層,和 24 小時(shí)有人值班的警報(bào)控制中心,以及所有即將被火勢(shì)蔓延的區(qū)域,都要啟動(dòng)有聲警報(bào)。所采用的墻紙必須為防火類(lèi)型,且符合地方消防建筑法規(guī)。 (e) Building height is measured from external fire brigade access level to finished floor level of the highest inhabited floor. Note that this may vary around the perimeter of the building 建筑高度的計(jì)算,是從室外消防通道地飾面,到有人居住的最高樓層地飾面的高度。 Materials 結(jié)構(gòu)和材料 (a) A minimum fire resistance rating shall be achieved in the building structure including but not limited to the following areas: floors, columns, beams, loadbearing walls, stairs and lift/elevator shafts, chimney and plumbing service s
點(diǎn)擊復(fù)制文檔內(nèi)容
黨政相關(guān)相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1