220kv大型變電所電氣主接線方案與設(shè)備布置初步設(shè)計(jì)稿畢業(yè)論文-wenkub

2023-05-28 23:18:18 本頁(yè)面
 

【正文】 rizing our coumtry39。 To ensure that the electric wiring, use transformer sets,capacity and type。 the mainelectrical equipment To relay protection configuration and lightning protectionplanning and design.Key words: Substation ; short–circuit currents ; electric equipment ; powerdistribution equipment220kV 大型變電所電氣主接線方案與設(shè)備布置初步設(shè)計(jì)目錄引言................................................................ 112設(shè)計(jì)說(shuō)明書(shū)....................................................... 21.1 電氣主接線設(shè)計(jì) ...............................................2 220 kV 電氣主接線..........................................2 110 kV 電氣主接線..........................................3 10 kV 電氣主接線...........................................4 所用電接線................................................. 41.2 負(fù)荷計(jì)算及變壓器選擇 .........................................5 負(fù)荷計(jì)算................................................... 5 主變臺(tái)數(shù)、容量和型式的確定.................................5 所用變臺(tái)數(shù)、容量和型式的確定............................... 7 最大持續(xù)工作電流及短路計(jì)算 ....................................8 各回路最大持續(xù)工作電流.....................................8 短路電流計(jì)算點(diǎn)的確定和短路電流計(jì)算結(jié)果..................... 8 主要電氣設(shè)備選擇 .............................................10 高壓斷路器的選擇..........................................12 隔離開(kāi)關(guān)的選擇............................................12 母線的選擇................................................ 12 絕緣子和穿墻套管的選擇....................................13 電流互感器的配置和選擇....................................13 電壓互感器的配置和選擇....................................14 各主要電氣設(shè)備選擇結(jié)果一覽表.............................. 15設(shè)計(jì)計(jì)算書(shū)...................................................... 182.1 短路電流計(jì)算書(shū) ..............................................18 短路計(jì)算等值電路圖........................................18220kV 大型變電所電氣主接線方案與設(shè)備布置初步設(shè)計(jì) 短路電流的計(jì)算............................................182.2 主要電氣設(shè)備選擇計(jì)算書(shū) ......................................23 高壓斷路器的選擇計(jì)算......................................23 隔離開(kāi)關(guān)的選擇計(jì)算........................................25 母線的選擇計(jì)算............................................27 絕緣子和穿墻套管的選擇計(jì)算................................ 28 電流互感器的選擇計(jì)算......................................29 電壓互感器的選擇計(jì)算......................................30 避雷針保護(hù)范圍的計(jì)算......................................30 避雷器的選擇..............................................31345配電裝置........................................................ 323.1 配電裝置設(shè)計(jì)的基本要求 ......................................323.2 配電裝置的選型和布置 ........................................32防雷保護(hù)的設(shè)計(jì).................................................. 344.1 概述 ........................................................ 34 直擊雷過(guò)電壓保護(hù)..........................................34 雷電侵入波保護(hù)............................................344.2 避雷針和避雷器的配置原則 ....................................34 避雷針的配置原則..........................................34 避雷器的配置原則..........................................354.3 避雷針的選擇 ................................................ 35 多支避雷針保護(hù)范圍的確定方法.............................. 35 本變電站避雷針的選擇結(jié)果..................................354.4 避雷針的選擇 ................................................ 35 避雷器類(lèi)型的選擇..........................................35 ZnO 避雷器的選擇原則......................................35 避雷器的選擇結(jié)果 .........................................36繼電保護(hù)配置.................................................... 37220kV 大型變電所電氣主接線方案與設(shè)備布置初步設(shè)計(jì)5.1 概述 ........................................................ 37 繼電保護(hù)的作用 ...........................................37 對(duì)繼電保護(hù)的基本要求 .....................................375.2 主變壓器保護(hù) ................................................ 37 主變壓器的主保護(hù)..........................................37 主變壓器的后備保護(hù)........................................375.3 線路及母線保護(hù) ..............................................38 220KV 線路保護(hù)............................................38 110KV 線路保護(hù)............................................38 10KV 線路保護(hù).............................................38 母線保護(hù) ................................................. 386 結(jié)束語(yǔ)........................................................... 39參考文獻(xiàn)........................................................... 40致謝............................................................... 41附錄............................................................... 42220kV 大型變電所電氣主接線方案與設(shè)備布置初步設(shè)計(jì)引 言能源是社會(huì)生產(chǎn)力的重要基礎(chǔ),隨著社會(huì)生產(chǎn)的不斷發(fā)展,人類(lèi)使用能源不僅在數(shù)量上越來(lái)越多,在品種及構(gòu)成上也發(fā)生了很大的變化。電能的發(fā)、變、送、配和用電,幾乎是在同時(shí)瞬間完成的,須隨時(shí)保持功率平衡。它承擔(dān)著變換電壓、接受和分配電能、控制電力的流向和調(diào)整電壓的責(zé)任。提高專(zhuān)業(yè)知識(shí),拓寬、提高專(zhuān)業(yè)知識(shí),完善知識(shí)結(jié)構(gòu),開(kāi)發(fā)創(chuàng)造型思維,提高專(zhuān)業(yè)技術(shù)水平和管理,增強(qiáng)計(jì)算機(jī)應(yīng)用能力,成為一專(zhuān)多能的高層次復(fù)合型人才。220kV 終端變電所的配電裝置,當(dāng)能滿足運(yùn)行要求時(shí),宜采用斷路器較少的或不用斷路器的接線,如線路變壓器組或橋形接線等。110~220kV 母線避雷器和電壓互感器,宜合用一組隔離開(kāi)關(guān),安裝在出線上的耦合電容器、電壓互感器以及接在變壓器引出線或中性點(diǎn)上的避雷器,不應(yīng)裝設(shè)隔離開(kāi)關(guān),在一個(gè)半斷路器接線中,前兩串的線路和變壓器出口處應(yīng)裝設(shè)隔離開(kāi)關(guān)。第 3 頁(yè) 共 40 頁(yè)方案項(xiàng)目方案Ⅰ雙母線接線方案Ⅱ雙母線帶旁路接線接線可靠性母線檢修時(shí),電源和出線可繼續(xù)工作,不會(huì)中斷對(duì)用戶供電。也可以閉合母聯(lián) QF,雙母線同時(shí)工作運(yùn)行調(diào)度靈活,但二次接線和繼電保護(hù)較復(fù)雜經(jīng)濟(jì)性經(jīng)濟(jì)性較好,便于擴(kuò)建設(shè)備多,占地面積大,投資大方案項(xiàng)目方案Ⅰ雙母線接線方案Ⅱ雙母帶旁路接線可靠性較高的可靠性可靠性很高靈活性靈活性較高靈活性很高經(jīng)濟(jì)性經(jīng)濟(jì)性較好,便于擴(kuò)建增加了設(shè)備和投資220kV 大型變電所電氣主接線方案與設(shè)備布置初步設(shè)計(jì)圖 110kV 電壓側(cè)接線方案 10 kV 電氣主接線備選接線方案:?jiǎn)文妇€分段接線、雙母線接線表 13 10kV 方案比較由于 10kV 所傳輸?shù)墓β什淮?,而雙母線接線所需設(shè)備較多,投資較大,故從經(jīng)濟(jì)角度考慮,確定 10kV 采用單母線分段的主接線方式。2. 所用電接線的確定由于本所內(nèi)有較低電壓(10kV)母線時(shí),所以從 10kV 母線上引接 2 臺(tái)所用變壓器,分別接于 10kV 母線的Ⅰ段和Ⅱ段,互為備用,平時(shí)運(yùn)行當(dāng)一臺(tái)故障時(shí)另一臺(tái)能承受變電所的全部負(fù)荷。2對(duì)地區(qū)性孤立的一次變電所或大型工業(yè)專(zhuān)用變電所,在設(shè)計(jì)時(shí)應(yīng)考慮裝設(shè)三臺(tái)主變電所的可能性。第 5 頁(yè) 共 40 頁(yè)220kV 大型變電所電氣主接線方案與設(shè)備布置初步設(shè)計(jì)2.主變?nèi)萘康拇_定主變壓器容量的確定要求:1主變壓器容量一般按變電所建成后 5~10 年的規(guī)劃負(fù)荷選擇,并
點(diǎn)擊復(fù)制文檔內(nèi)容
公司管理相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖片鄂ICP備17016276號(hào)-1