【正文】
gn of Shilong sewage treatment plant design process, the main task is to plete the design of the regional sewage treatment. The sewage treatment plant project, a scale of 40,000 tons one day, two scale of 60,000 tons one day. Design a construction scale SBR and A2/O process, oxidation ditch process were pared to determine the final selection of the nitrogen and phosphorus removal treatment effect, easy operation and management, investment in the province of the A2/O process. To further enhance the effect of nitrogen and phosphorus removal and reduce energy consumption, a certain improvement of the A2/O process. Sewage in the process first by upgrading the pumping station upgraded to fine grid, and then swirl grit chamber of a handle, and then into the bioreactor anoxic, anaerobic pond and aerobic pond, which to be a mixture of return and sludge return. The main function of the anaerobic pond is the release of phosphorus, part of the organic matter, ammonification。厭氧池主要功能是釋放磷,同時部分有機物進行氨化;缺氧池的主要功能是脫氮,好氧池能夠去除BOD硝化和吸收磷。該污水處理廠工程,一期規(guī)模為4萬噸/日,二期規(guī)模為6萬噸/日。本設計對一期建設規(guī)模將SBR法、A2/O工藝、氧化溝工藝進行了比較,最終確定選用脫氮除磷處理效果好、運行管理方便、投資省的A2/O工藝。然后污水進入輻流式二次沉淀池,再進入接觸消毒池,最后出水。 main function is to anoxic denitrification, aerobic tank removal of BOD5, nitrification and phosphorus absorption. Sewage into the radial flow sedimentation tank, and then enter the contact disinfection tank, the final effluent. Excess sludge discharged from the reaction tank and secondary settling tank into the sludge storage tanks, sewage pumps into a concentrated pool, and finally into the sludge dewatering room for dehydration, and finally Sinotrans disposal. The design process through the design and selection of the design calculations of all structures and ancillary structures, plete a plane, elevation layout of the entire plant, and then pleted the process design of the urban sewage treatment plants. Key words:Shilong,Dongguan。1 緒論 水資源是人類賴以生存的基本物質之一,已成為人類社會可持續(xù)發(fā)展的重要限制因素。掌握設計手冊、設計規(guī)范、設計標準的應用;制定城市污水處理廠設計方案,設計計算單體構筑物、管道布置、高程布置,完成詳細設計說明書的編制,繪制設計圖紙。屬亞熱帶季風氣候,長夏無冬,日照充足,雨量充沛,溫差振幅小,季風明顯。、水質與出水指標(1)一期:平均日污水量4104m3/d,總變化系數(shù)Kz=,最大時流量2350m3/h。在方案比選時,主要控制的條件有用地范圍、尾水排放、污泥出路、地質條件、發(fā)展余地、管理水平、運行費用、工程投資、環(huán)境影響等諸方面。(2)經濟節(jié)能“運行費用低、造價低和占地少”是經濟節(jié)能的基本要求。(3)易于管理操作管理方便,設備可靠且維修簡單是基本要求。 A2/O工藝厭氧缺氧好氧(簡稱A/A/O或A2/O)工藝,是在一個系統(tǒng)中同時具有厭氧區(qū)、缺氧區(qū)、好氧區(qū),能夠同時做到脫氮、除磷和有機物的降解??赏ㄟ^雙池或多池組合運行實現(xiàn)連續(xù)進出水。氧化溝使用一種帶方向控制的曝氣和攪動裝置,向反應池中的物質傳遞水平速度,從而使被攪動的液體在閉合式渠道中循環(huán)。微生物的氧化過程消耗了水中溶解氧,直到DO值降為零,混合液呈缺氧狀態(tài)。 工藝比較 A2/O工藝與其他常規(guī)生物處理工藝的比較見下表。缺點,對自動化控制能力要求高;;;。 根據(jù)以上工藝比較,本設計選取相對較好的A2/O工藝,但是為了進一步提高脫氮除磷效果和節(jié)約能耗,對A2/O工藝進行了改進,將厭氧池和缺氧池倒置后的A2/O改良工藝。小型潛水污水泵,單臺流量為Q=250m3/h,揚程H=8m,電機功率為15kW,共設3臺。(6)機械清渣設備:采用鏈條式格柵除污機2臺。沉砂用的砂泵經砂抽吸管、排砂管清洗后排除,清洗水回流至沉砂區(qū)。表41 旋流式沉砂池型號200的尺寸(m)型號流量(L/s)ABCDEFGHJKL200180圖42鐘式沉砂池各部分尺寸 A2/O設計計算(1)設計參數(shù) 設計最大流量:Q=40000m3/d 設計進水水質:COD=250mg/L;BOD5(S0)=140mg/L;SS=150mg/L;TN=45mg/L;NH3N=25mg/L;TP=;pH=7~9。剩余堿度SALK1=進水堿度-硝化消耗堿度+反硝化產生堿度+去除BOD5產生堿度%計,則每日用于合成的總氮=1312=(kg/d)即進水總氮中有(1000)/40000=(mg/L),用于合成。將實際需氧量AOR換算成標準狀態(tài)下的需氧量SOR式中,ρ為氣壓調整系數(shù),105Pa;CL為曝氣池內平均溶解氧,取2mg/L;Cs(20)=,Cs(25)=。采用微孔曝氣器,參照有關手冊,在供風量1~3m3/(h厭氧池有效容積V厭=50=1500(m3)混合全池污水所需功率為51500=7500(W)(9)缺氧池設備選擇(以單組反應池計算)缺氧池設導流墻,將厭氧池分為3格,每格內設潛水攪拌機1臺,所需功率按5W/m3計算。圖44周進周出輻流式二沉池構造簡圖1—過橋;2—欄桿;3—傳動裝置;4—轉盤;5—進水下降管;6—中心支架;7—傳動器罩; 8—耙架;9—出水管;10—排泥管;11—刮泥板;12—可調節(jié)的橡皮刮板(1)二沉池主要尺寸1)沉淀部分水面面積F設池數(shù)n=2個,表面負荷q39。h)]5)單池設計流量Q0(m3/h)6)澄清區(qū)高度h239。=2h,(m)8)池邊深度h2h2=h239。(3)出水部分設計單池設計流量Q單=Q/2==(m3/s)環(huán)形集水槽內流量q集=Q單/2==(m3/s)①采用周邊集水槽,單側進水,每池只有一個總出水口,集水槽寬度(取b=)集水槽起點水深h起===集水槽終點水深h終===②采用雙側集水環(huán)形集水槽計算,取槽寬b=,槽中流速v=槽內終點水深m槽內起點水深mm,+(超高)=,采用90176。2)每個三角堰的流量q1===(m3/s)3)三角堰個數(shù)n1=Q單/q1==280(個)4)三角堰中心距(單側進水)m(5)排泥部分設計1)單池污泥量總污泥量為回流污泥量加剩余污泥量回流污泥量Qr=Qr=1=(m3/h)剩余污泥量(m3/d)=(m3/h)Q泥總=Qr+Qs=+=(m3/h)Q單=Q泥總/2==(m3/h)2) 集泥槽沿整個池徑為兩邊集泥 設計泥量為q=Q單/2==(m3/h)=(m3/s)集泥槽寬b===(取b=)起點泥深h1===(取h1=)終點泥深h2===(取h2=)() 接觸消毒池設計計算 城市污水經過一級或二級處理后,水質改善,細菌含量也大幅度減少,但其絕對值仍很可觀,并有存在病源菌的可能。所以,目前污水消毒一是要控制恰當?shù)耐秳┝?,二是采用其他消毒劑代替液氯或游離氯,以減少有害物的生成。目前常用的污水消毒劑是液氯,其次是漂白粉、臭氧、次氯酸鈉、氯片、氯氨、二氧化氯和紫外線等。 (2)設計計算1)設計消毒池一座,池體容積V=Q=BLH=15154= 900m3,滿足有效停留時間的要求。接觸消毒池設計為縱向折流反應池。 選用TSD150 型鼓風機三臺,工作兩臺,備用一臺。 混合液回流泵房設混合液回流泵房2座,每座泵房內設3臺潛污泵(2用1備)單泵流量QR單==(m3/h)設計鼓風機房占地LB=88=64m2,高6m。 污泥濃縮池設計計算 降低污泥中的含水率,可以采用污泥濃縮的方法來降低污泥中的含水率,減少污泥