【正文】
e, method and the conclusion of the design choices in the design of certain ten layers of office building. This paper mainly includes five chapters content, can be divided into five parts: the introduction, the system load calculations, the design of low voltage power supply and distribution system, lighting system design, lightning protection grounding system design. The introduction part includes: the design of the purpose and significance, domestic and foreign research review overall scheme, design contents, design the overall program, etc. System load calculations part includes: power load level, the significance of load calculation and method, etc. Low voltage power supply and distribution system design part includes: power distribution scheme, selection of cable, cable laying , protecting electric appliance choice, draw the distribution system plan, etc. Lighting system design part includes: the intensity of illumination, intensity of illumination putation, lighting mode selection, choice of light source, lamps selection and layout, socket selection and layout, draw the lighting layout plan, etc. Lightning protection and grounding system design part includes:antimine grade determined, a variety of lightning protection measures, buildings’ potential protection measures ,draw lightning protection and grounding plan, etc. Keywords: system load calculations; low voltage power supply and distribution system; lighting system; lightning protection and grounding system i 目 錄 中文摘要 系統(tǒng)負(fù)荷計(jì)算部分包括:電力負(fù)荷級(jí)別、負(fù)荷計(jì)算目的意義及方法等。 本科畢業(yè)設(shè)計(jì) (論文 ) 題目:高層辦公樓供配電設(shè)計(jì) 院 (系): 電子信息工程學(xué)院 專 業(yè): 電氣工程及其自動(dòng)化 班 級(jí): 090411 學(xué) 生: 學(xué) 號(hào): 指導(dǎo)教師: 2020 年 6 月 本科畢業(yè)設(shè)計(jì) (論文 ) 題目:高層辦公樓供配電設(shè)計(jì) 院 (系): 電子信 息工程學(xué)院 專 業(yè): 電氣工程及其自動(dòng)化 班 級(jí): 學(xué) 生: 學(xué) 號(hào): 指導(dǎo)教師: 2020 年 6 月 I 高層辦公樓供配電設(shè)計(jì) 摘 要 本論文主要闡述了某十層辦公樓各系統(tǒng)電氣設(shè)計(jì)的設(shè)計(jì)依據(jù)、原則、方法及設(shè)計(jì)選擇的結(jié)論。 低壓供配電系統(tǒng)設(shè)計(jì)部分包括:配電方案、導(dǎo)線電纜的選擇、線路的敷設(shè)、保護(hù)電器的選擇、 繪制配電系統(tǒng)圖 等。4 負(fù)荷計(jì)算的方法 12 配電箱的選擇 15 ii 4 照明系統(tǒng)的設(shè)計(jì) 16 照明的種類 26 正常照明燈具的 布置 26 插座系統(tǒng)的設(shè)計(jì) 27 照明負(fù)荷平面布置圖 29 防雷系統(tǒng)概述 30 高層建筑物的防雷措施 36 畢業(yè)設(shè)計(jì) (論文 )獨(dú)創(chuàng)性聲明 44 1 緒論 1 1 緒論 辦公樓照明與供配電系統(tǒng)概述 隨著人們生活水平的提高,高質(zhì)量的生活對(duì)于建筑物的要求也越來越高,人們對(duì)于高層建筑物的要求也越來越高。照明系統(tǒng)設(shè)計(jì)主要包括照明方式及種類的分類、照度的計(jì)算、光源的選擇、燈具和插座的選擇及布置。一定要以建筑物防雷設(shè)計(jì)規(guī)范為依據(jù),進(jìn)行防雷措施的選擇。 設(shè)計(jì)的目的和意義 通過設(shè)計(jì)實(shí)現(xiàn)簡(jiǎn)捷實(shí)用、便于操作、管理和維護(hù),減少綜合投資的目的。然而合理的供配電系統(tǒng)設(shè)計(jì)不僅節(jié)省一次性的投資,而且對(duì)提高供電質(zhì)量、節(jié)約大量的電氣材料、節(jié)約運(yùn)行中的電能、便于日常運(yùn)行管理和維修等都具有較大的現(xiàn)實(shí)意義。特別是工業(yè)發(fā)達(dá)國(guó)家已經(jīng)逐步形成了一批定型的智能化供配電系統(tǒng)產(chǎn)品,這種智能化的供配電系統(tǒng)除了具備常規(guī)供配電系統(tǒng)應(yīng)有的功能外,還有很多其他的功能,比如:遠(yuǎn)程自動(dòng)監(jiān)測(cè)變配電設(shè)備的運(yùn)行狀況和運(yùn)行參數(shù),遠(yuǎn)程控制或自動(dòng)控制變配電設(shè)備的運(yùn)行,與樓宇自控系統(tǒng)或者建筑設(shè)備監(jiān)控 系統(tǒng)通信聯(lián)網(wǎng)等功能。現(xiàn)代的高層建筑供配電系統(tǒng)的設(shè)計(jì)已經(jīng)將弱電技術(shù)和強(qiáng)電技術(shù)融合在了一起,形成了新一代的電氣技術(shù)。 ( 2)低壓供配電系統(tǒng)設(shè)計(jì),如供電電源和電壓的選擇,導(dǎo)線電纜的選擇、線路敷設(shè)方式的選擇、保護(hù)電器的選擇、供配電系統(tǒng)圖等。根據(jù)相關(guān)規(guī)范完成該辦公樓的供配電設(shè)計(jì)。 研究的方法和措施 通過查閱 相關(guān)書籍、瀏覽網(wǎng)頁(yè)、請(qǐng)教老師及同學(xué)、學(xué)習(xí)相關(guān)規(guī)范、根據(jù)畢業(yè)設(shè)計(jì)任務(wù)書的要求,首先將該設(shè)計(jì)分為四個(gè)部分 —負(fù)荷計(jì)算、低電壓供配電系統(tǒng)設(shè)計(jì)、照明系統(tǒng)的設(shè)計(jì)、防雷接地系統(tǒng)的設(shè)計(jì),然后通過對(duì)辦公樓供配電設(shè)計(jì)相關(guān)知識(shí)的學(xué)習(xí)將四部分內(nèi)容逐漸細(xì)化,然后逐步完成各部分的設(shè)計(jì)。 3)必須從全局出發(fā),統(tǒng)籌兼顧,按照負(fù)荷性質(zhì)、用電容量、工程特點(diǎn)和地區(qū)供電條件,合理確定設(shè)計(jì)方案。計(jì)算負(fù)荷不能定得太大,否則選擇的電氣設(shè)備和導(dǎo)線電纜將會(huì)過大而造成投資和有色金屬的浪費(fèi);當(dāng)然計(jì)算負(fù)荷也不能定得太小,否則選擇的電氣設(shè)備和導(dǎo)線電纜將會(huì)長(zhǎng)期處于過負(fù)荷下運(yùn)行,增加 電能損耗,導(dǎo)致絕緣體過早老化甚至燒毀。 一級(jí)負(fù)荷應(yīng)由兩路獨(dú)立電源供電,在一級(jí)負(fù)荷中的特別重要負(fù)荷,除上述兩個(gè)獨(dú)立電源外,還必須增設(shè)應(yīng)急電源。 三級(jí)負(fù)荷一般由單回路供電。計(jì)算負(fù)荷又稱需要負(fù)荷或者最大負(fù)荷。 負(fù)荷計(jì)算的方法 計(jì)算負(fù)荷的方法很多,主要有需要系數(shù)法和二項(xiàng)式法。它既簡(jiǎn)便又實(shí)用,因?yàn)槊裼媒ㄖ袉螜C(jī)負(fù)荷較大的各類設(shè)備都是采用單機(jī)組或同類機(jī)群放射式 供電,在計(jì)及供電線路、開關(guān)時(shí),都是用單機(jī)的額定電流或起動(dòng)電流進(jìn)行選型或校驗(yàn)的,所以普遍采用需要系數(shù)法。 ( 1)用電設(shè)備組計(jì)算負(fù)荷基本公式: 有功計(jì)算負(fù)荷(單位為 kw ) 30 deP K P? ( ) 式中,eP—用電設(shè)備組總的設(shè)備容量(不含備用設(shè)備容量,單位為 kw)。辦公樓需要系數(shù)Kn=。 Pc—單相照明線路的計(jì)算負(fù)荷, W。 Pc—三相照明線路的計(jì)算負(fù)荷, W。對(duì)于容量 較大的集中負(fù)荷或重要用電設(shè)備,應(yīng)從配電室以放射式配電。如一級(jí)負(fù)荷容量不大時(shí),應(yīng)優(yōu)先采用從電力系統(tǒng)或鄰近單位取得第二低壓電源,亦可采用應(yīng)急發(fā)電機(jī)組,如一級(jí)負(fù)荷僅為照明或電話站負(fù)荷時(shí),宜采用蓄電池組作為備用電源。在負(fù)荷較小或供電條件困難時(shí),二級(jí)負(fù)荷可由一回 6kV 及以上專用的架空線路或電纜供電。 三級(jí)負(fù)荷對(duì)供電無特殊要求,一般有單電源供電即可。 導(dǎo)線電纜的選擇 導(dǎo)線電纜的選擇原則 在建筑電氣工程中,需要大量的導(dǎo)線和電纜,正確選擇導(dǎo)線和電纜,是保證用電安全可靠必不可少的重要條件。 比較提倡選用銅線,以減少損耗,節(jié)約電能,特別在易爆炸、腐蝕嚴(yán)重的場(chǎng)所,以及用于移動(dòng)設(shè)備、檢測(cè)儀表等,必須采用銅線。根據(jù)負(fù)荷計(jì)算結(jié)果以及計(jì)算電流,合理的選擇導(dǎo)線及電纜。進(jìn)行導(dǎo)線截面的選擇時(shí)需要遵循以下原則: 1)根據(jù)允許載流量選擇導(dǎo)線和電纜 截面 在導(dǎo)線和電纜(包括母線)通過正常最大負(fù)載電流(即計(jì)算電流)時(shí),其發(fā)西安工業(yè)大學(xué)畢業(yè)設(shè)計(jì)(論文) 10 熱溫度不應(yīng)該超過正常運(yùn)行時(shí)的最高允許溫度,以防止導(dǎo)線或電纜因過熱而引起絕緣損壞或老化。 3)根據(jù)經(jīng)濟(jì)電流密度選擇導(dǎo)線和電纜截面 經(jīng)濟(jì)電流密度是 指使線路的年運(yùn)行費(fèi)用支出最小的電流密度。對(duì)電纜不必校驗(yàn)其機(jī)械強(qiáng)度。 選擇導(dǎo)線截面時(shí),要求在滿足上述 5 個(gè)原則的基礎(chǔ)上選擇其中最大的截面。 caln III ?? () 式中 In——導(dǎo)線或者電纜長(zhǎng)期允許的工作電流, A; Ial——導(dǎo)線或電纜允許載流量, A; Ic——線路計(jì)算電流, A。 對(duì)于插座回路,每個(gè)插座的容量按 200W 算,單回路的插座個(gè)數(shù)不超過 10 個(gè)為宜,所以插座回路選線為: BV3*。 線路敷設(shè)形式的選擇 本設(shè)計(jì)照明回路暗敷設(shè)在屋面或頂板內(nèi),插座回路及空調(diào)回路暗敷設(shè)在墻內(nèi),其他回路沿墻面敷設(shè)。塑料管暗敷或埋地敷設(shè)時(shí),引出地(樓)面的一段管路,采取防止機(jī)械損傷的措施。電纜橋架內(nèi)每根電纜每隔 50m 處,電纜的首端、尾端及主要轉(zhuǎn)彎處應(yīng)設(shè)標(biāo)記,注明電纜編號(hào)、型號(hào)規(guī)格、起點(diǎn)和終點(diǎn)。電纜的穿墻處保護(hù)管兩端應(yīng)采用難燃材料 封堵。 配電箱的選擇 PZ30 系列配電箱采用塑料面板,金屬箱體,內(nèi)置接零端子適用于電壓 380V,負(fù)載電流 100A 以下漏電保護(hù)等終端控制設(shè)備。該箱載入總負(fù)載電流不超過 250A。 表 38 KP30 系列配電箱型號(hào)及尺寸 型號(hào) 外形尺寸 預(yù) 埋箱尺寸 A B C D E F G H K KP306 200 230 173 200 100 130 263 200 100 KP3