【正文】
(論文) 目錄 1 前 言 ....................................................... 1 建筑電氣簡介 .............................................. 1 .................................................. 1 設計原則 .................................................. 1 ................................................. 5 ....................... 5 3低壓配電系統設計 ............................................. 8 負荷等級及供電要求 ....................................... 8 負荷等級分類 ........................................... 8 負荷計算 ................................................. 8 計算照明負荷 ............................................ 8 ........................................... 11 設備選型結果 ............................................ 13 配電方式 ................................................ 13 4 防雷接地系統設計 ............................................ 15 ......................................... 15 ............................................. 15 ............................... 16 ................................. 18 ....................................... 18 接地系統設計 ........................................... 18 5 結 論 ..................................................... 20 參考文獻 ..................................................... 21 致 謝 ....................................................... 22 附錄 ......................................................... 23 I 安徽建筑工業(yè)學院畢業(yè)設計(論文) 摘 要 本次畢業(yè)設計為合肥市某辦公樓的電氣設 計。在整個設計中,本人依據國家有關的設計規(guī)范和標準以及相關專業(yè)提供的設計資料,對這個工程的強電系統進行設計。設計的主要內容包括低壓配電系統、一至三層電氣照明系統及防雷接地系統,照明系統主要說明一般照明燈具及插座的選擇,照度及照明計算負荷計算,應急照明的選擇及安裝等,用利用系數法進行計算,計算出各個房間合適的燈具數量。配電及布線方面,設計出各個供電回路相應的配電箱及走線方式,計算出各回路的計算負荷,最后選擇好各個回路所需的線纜型號和保護器件型號,滿足正常生活和安全的需要。對建筑防雷的設計 ,主要進行平面圖設計。 做完本畢業(yè)設計對建筑電氣有了較為全面的認識。 關鍵詞:電氣照明 ,配電系統 ,設備選型 ,防雷接地 II 安徽建筑工業(yè)學院畢業(yè)設計(論文) ABSTRAC The graduation design for a building in hefei the electrical design. In the whole design, I according to relevant state design specifications and standards and relevant professional design material, to the project in high voltage system design. The design of the main content including low voltage distribution system, a second floor electrical lighting system and lightningproof grounding system, lighting system that major general lighting lamps and lanterns and socket choice, intensity of illumination and lighting calculation load calculation, emergency lighting selection and installation, etc, with the utilization coefficient method for the calculation, each room right out the lamps and lanterns of quantity. Distribution and wiring, the power supply circuit design each corresponding distribution box and go line way, calculate the calculation of the loop load, and finally choose good each loop the cable, Finish the graduation design of building electrical can have a prehensive understanding of the architectural electrical design . Key Words: Electrical lighting。 Distribution system。 Equipment selection。 Lightningproof grounding。 III 安徽建筑工業(yè)學院畢業(yè)設計(論文) 某辦公樓建筑電氣 設計 1 前 言 建筑電氣簡介 建筑電氣是指電氣工程技術在在建筑中的應用。隨著建筑技術和電氣科技的發(fā)展,尤其是隨著信息技術的發(fā)展,如計算機技術、數字技術、顯示技術、網絡技術以及現代通信技術的發(fā)展,使建筑電氣技術實現了飛躍性的發(fā)展,建筑科技含量越來越高。隨著建筑電氣新產品、新技術的不斷涌現,建筑電氣向著專業(yè)技術更加綜合的方向發(fā)展。 該工程是六層辦公建筑,一層是本樓大廳,二層和三層是辦公區(qū)。本設計的目的是通過對該辦公樓電氣照明及防雷接地系統的設計,依據我國現行的相關設計規(guī) 范,利用所學專業(yè)知識,理論聯系實際,鍛煉解決問題的能力,為自己以后的實際工作打下一定的基礎。 設計原則 本次設計是辦公樓的電氣設計,該樓以辦公為主。設計堅持最大限度地滿足用戶合理需求的原則,設計需做到方案合理、運行可靠、簡捷實用、便于操作、管理和維護,根據建筑物的設計要求,綜合考慮國家現行的規(guī)范。在滿足用戶需求條件下,貫徹經濟、適用的原則,減少各方面的投資,降低資源消耗,節(jié)約運行費用。建筑電氣設計貫徹安全的原則,滿足保障人身、設備和建筑物安全。使得建筑物達到滿意適用、安全可靠、技術先進、經濟合理 、管理方便的要求。 本論文主要闡述了辦公樓各系統電氣設計的設計依據、原則和方法及設計選擇的結論等。論文共包括 3章內容。 1 安徽建筑工業(yè)學院畢業(yè)設計(論文) 本部分主要說明光源、燈具選擇,照度計算,一般照明及應急照明等內容。 本系統照度計算采用利用系數法進行計算,選擇出各個房間合適的燈具數量, 同時進行應急照明設計,本部分設計出圖為各層照明平面圖。 本部分主要說明負荷等級的劃分及對應的供電要求,負 荷計算以及配電方 式等內容的相關原理、原則、方法等,并用需要系數法進行了負荷計算,確定 各個系統照明負荷的容量、計算電流。從而選擇出合適的配電線路線纜和保護 設備如斷路器,漏電保護裝置等,以及各個供電回路相對應的配電箱。本部分 設計出圖為低壓配電系統圖。 本部分主要說明防雷建筑物的分類及對應的防雷措施,對直擊雷、雷電感 應等的防護以及接地系統的方式及具體要求等內容,結合本建筑特點,做了防 雷及接地系統設計,本部分設計出圖為防雷平面圖。 2 安徽建筑工業(yè)學院畢業(yè)設計(論文) 2電氣照明系統設計 總則 電氣照明設計的基本原則主要是安全、舒適、經濟。為了最大限度的滿足使用要求,同時符合相應國家設計規(guī)范,使照明設計盡量經濟適用。就要合理選擇照明方式、光源種類、燈泡功率、照明器數量。 本次設計的綜合樓為綜合辦公樓,辦公照明一般設計原則 ( 1)辦公樓的使用要求主要是人員的辦公照明,照度太低會損害工作人員的視力,不合理的高照度則會浪費電力,照明設計要形成舒適的照明環(huán)境。辦公室照明燈具宜采用熒光燈。 插 座按照辦公需要合理布置。并設置空調插座。 ( 2)在樓梯間、公共走廊等人流疏散通道應設置應急照明和疏散指示。 ( 3)辦公建筑照明標準值依據建筑照明設計標準 (GB50