【正文】
畢業(yè)設(shè)計(jì)說明書110kV變電站一次部分電氣設(shè)計(jì) 畢業(yè)設(shè)計(jì)(論文)任務(wù)書姓名專業(yè)班級(jí)畢業(yè)設(shè)計(jì)(論文)題目110kV變電站一次部分電氣設(shè)計(jì)畢業(yè)設(shè)計(jì)(論文)工作起止時(shí)間2地點(diǎn)廣東畢業(yè)設(shè)計(jì)(論文)的內(nèi)容:1. 分析原始資料,選擇電氣主接線選擇主變壓器的臺(tái)數(shù)及容量,對(duì)初選24種電氣主接線進(jìn)行技術(shù)比較,淘汰較差的方案,保留較好的方案;2. 計(jì)算短路電流;3. 主要電氣設(shè)備選擇及校驗(yàn); 畢業(yè)設(shè)計(jì)(論文)的要求:完成設(shè)計(jì)內(nèi)容,要求方案設(shè)計(jì)論證充分,設(shè)備選擇合理,計(jì)算準(zhǔn)確。撰寫畢業(yè)論文1份,正文字?jǐn)?shù)在12000左右,要求有規(guī)范的目錄和參考文獻(xiàn),其它參照成教學(xué)院的文件要求。繪制電氣主接線圖1張。畢業(yè)設(shè)計(jì)(論文)工作進(jìn)度計(jì)劃::收集資料,形成論文總體框架,完成中期審查。:完成論文最終稿。 本任務(wù)書于 日前完成,由指導(dǎo)老師審閱后,提交畢業(yè)設(shè)計(jì)(論文)指導(dǎo)小組進(jìn)行答辯。指導(dǎo)教師 制定 年 月 日畢業(yè)設(shè)計(jì)(論文)指導(dǎo)小組組長 制定 年 月 日辦學(xué)單位負(fù)責(zé)人 制定 年 月 日畢業(yè)設(shè)計(jì)(論文)評(píng)語指導(dǎo)教師評(píng)語:本論文根據(jù)某地區(qū)的用電需求及電力系統(tǒng)的可靠性、經(jīng)濟(jì)性要求,按照給出的原始資料和供應(yīng)電能的相關(guān)情況,設(shè)計(jì)出能夠滿足負(fù)荷增長需要的運(yùn)行靈活、檢修維護(hù)安全方便、接線簡單清晰、操作方便、投資少、運(yùn)行費(fèi)用低和有擴(kuò)建可能性的變電站主接線方案,并通過短路電流計(jì)算,選擇和校驗(yàn)其他電氣設(shè)備。該論文選題符合電力系統(tǒng)工程實(shí)際需要,結(jié)構(gòu)合理,數(shù)據(jù)資料充分,寫作進(jìn)度安排合理,文字表達(dá)較流暢,已達(dá)到畢業(yè)設(shè)計(jì)(論文)水平。 指導(dǎo)教師簽名 年 月 日評(píng)閱教師評(píng)語:隨著對(duì)電力系統(tǒng)電能質(zhì)量、發(fā)供電可靠性、技術(shù)經(jīng)濟(jì)指標(biāo)等的相關(guān)要求的日益提高,變電站的規(guī)劃設(shè)計(jì)成為電網(wǎng)發(fā)展的關(guān)鍵一環(huán),并將進(jìn)一步影響到整個(gè)社會(huì)的穩(wěn)定和國民經(jīng)濟(jì)的發(fā)展。本論文通過對(duì)原始資料的分析,結(jié)合電力系統(tǒng)的運(yùn)行實(shí)際情況,比較各種主接線設(shè)計(jì)方案,以確定最為可靠經(jīng)濟(jì)的的電氣主接線方案和主變?nèi)萘?。隨后通過短路電流計(jì)算,來選擇和校驗(yàn)主要電氣設(shè)備。論文結(jié)構(gòu)合理,思路清晰,計(jì)算數(shù)據(jù)翔實(shí),結(jié)論合理,已達(dá)到畢業(yè)設(shè)計(jì)(論文)要求的水平。 評(píng)閱教師簽名 年 月 日答辯小組評(píng)語:答辯小組組長簽名 年 月 日中 文 摘 要 變電站作為電力系統(tǒng)中的重要組成部分,直接影響整個(gè)電力系統(tǒng)的安全與經(jīng)濟(jì)運(yùn)行。本論文中待設(shè)計(jì)的變電站是一座降壓變電站,在系統(tǒng)中起著匯聚和分配電能的作用,擔(dān)負(fù)著向該地區(qū)工廠、農(nóng)村供電的重要任務(wù)。該變電站的建成,不僅增強(qiáng)了當(dāng)?shù)仉娋W(wǎng)的網(wǎng)絡(luò)結(jié)構(gòu),而且為當(dāng)?shù)氐墓まr(nóng)業(yè)生產(chǎn)提供了足夠的電能,從而達(dá)到使本地區(qū)電網(wǎng)安全、可靠、經(jīng)濟(jì)地運(yùn)行的目的。本論文《110kv變電站一次部分電氣設(shè)計(jì)》,首先通過對(duì)原始資料的分析及根據(jù)變電站的總負(fù)荷選擇主變壓器,同時(shí)根據(jù)主接線的經(jīng)濟(jì)可靠、運(yùn)行靈活的要求,選擇了兩種待選主接線方案進(jìn)行了技術(shù)比較,淘汰較差的方案,確定了變電站電氣主接線方案。其次進(jìn)行短路電流計(jì)算,從三相短路計(jì)算中得到當(dāng)短路發(fā)生在各電壓等級(jí)的母線時(shí),其短路穩(wěn)態(tài)電流和沖擊電流的值。再根據(jù)計(jì)算結(jié)果及各電壓等級(jí)的額定電壓和最大持續(xù)工作電流進(jìn)行主要電氣設(shè)備選擇及校驗(yàn)(包括斷路器、隔離開關(guān)、電流互感器、電壓互感器等)。最后,并繪制了電氣主接線圖、電氣總平面布置圖、防雷保護(hù)配置圖等相關(guān)設(shè)計(jì)圖紙。關(guān)鍵詞 電氣主接線設(shè)計(jì);短路電流計(jì)算;電氣設(shè)備選擇;設(shè)計(jì)圖紙AbstractPower system substation as an important part of the entire power system directly affects the safety and economic operation. To be designed in this paper is a stepdown substation substation in the system plays the role of aggregation and distribution of electric energy, charged with the factory to the region, the important task of rural electrification. The pletion of the substation will not only strengthen the local power grid network structure, but also for the local industrial and agricultural production provides enough power, so that the regional power grid so as to achieve safe, reliable and economic operation purposes.The paper 110kv substation once part of the electrical design, the first original data through the analysis and selection based on total load of the substation main transformer, the main wiring under both economical and reliable, flexible operation requirements, select the main connection of two programs to be selected A technical parison, out of poor program to determine the main electrical substation connection program.Second, the shortcircuit current calculation, obtained from the threephase short circuit calculation occurs when shortcircuit the voltage level of the bus, its steadystate current and the impact of shortcircuit current value. According to the results and the voltage level of voltage and maximum continuous operating current of the main electrical equipment selection and validation (including circuit breaker, disconnecting switch, current transformer, voltage transformer, etc.).Finally, the main draw of the electrical wiring diagram, electrical general layout map, lightning protection and other related design layout plan drawings. Keywords Electrical main wiring design。 shortcircuit current calculation。 electrical equipment selection。 design drawings目 錄第1章 設(shè)計(jì)的內(nèi)容和要求 1 原始資料分析 1 設(shè)計(jì)原則和基本要求 2 設(shè)計(jì)內(nèi)容 2第2章 主變壓器的選擇 3 主變臺(tái)數(shù)的確定 3 本變電站站用變壓器的選擇 4 小結(jié) 5第3章 電氣主接線的選擇 6 選擇原則 6 主接線設(shè)計(jì)的基本要求及原則 6 主接線的基本形式和特點(diǎn) 7 變電站的各側(cè)主接線方案的擬定 7 小結(jié) 11第4章 短路電流計(jì)算 12 短路計(jì)算的目的及假設(shè) 12 短路電流計(jì)算的步驟 12 短路電流計(jì)算及計(jì)算結(jié)果 13 小結(jié) 16第5章 導(dǎo)體和電氣設(shè)備的選擇 17 電氣設(shè)備的選擇原則 17 斷路器和隔離開關(guān)的選擇 17 互感器的選擇 20 母線的選擇 22 高壓熔斷器的選擇 24 消弧線圈的選擇 24 小結(jié) 25第6章 變電站防雷保護(hù)及其配置 26 直擊雷的過電壓保護(hù) 26 雷電侵入波的過電壓保護(hù) 26 避雷器和避雷線的配置 26 小結(jié) 27第7章 高壓配電裝置及平面布置 28 設(shè)計(jì)原則與要求 28 高壓配電裝置 29 小結(jié) 30結(jié) 論 31參考文獻(xiàn) 32致 謝 33附錄1 避雷針保護(hù)范圍圖 34附錄2 變電所總體平面布置圖 35附錄3 110KV/35KV/10KV降壓變電站電氣一次主接線圖 35第1章 設(shè)計(jì)的內(nèi)容和要求 原始資料分析變電站的建設(shè)規(guī)模(1)、類型:110kV地方變電站。(2)、最終容量: MVA,電壓為110kV/35kV/10kV的主變壓器,主變各側(cè)容量比為100/100/100,一次設(shè)計(jì)并建成。電力系統(tǒng)與本所的連接情況(1)、待設(shè)計(jì)的變電站是一座降壓變電站,擔(dān)負(fù)著向該地區(qū)工廠、農(nóng)村供電的重要任務(wù)。(2)、本變電站有兩回平行線路與110kV電力系統(tǒng)連接,有兩回35kV電力系統(tǒng)連接。圖1 變電所連接示意圖(3)、本變電站在系統(tǒng)最大運(yùn)行方式下的系統(tǒng)正、負(fù)阻抗的標(biāo)么值示意圖如圖1(Sj=100MVA),110kV及35kV電源容量為無窮大,阻抗值各包含平行線路阻抗在內(nèi)。圖1 變電所連接示意圖電所不考慮裝調(diào)相機(jī)、電容器等無功補(bǔ)償設(shè)備,35kV因電網(wǎng)線路的電容電流較少,也不裝設(shè)消弧線圈。110kV出線無電源。電力負(fù)荷水平110kV進(jìn)出線共2回,兩回進(jìn)線為110kV的平行供電線路,正常送電容量各為35000KVA。35kV進(jìn)出線共2回,兩回進(jìn)線連接著35kV電源,輸送容量各為35000KVA。10kV出線共12回,全部為架空線路,其中3回每回輸送容量按5000KVA設(shè)計(jì);另外5回每回輸送容量為4000KVA,再預(yù)留四個(gè)出線間隔,待以后擴(kuò)建。本變電站自用電主要負(fù)荷如表12