土木建筑外文翻譯外文文獻(xiàn)英文文獻(xiàn)消防自動(dòng)噴水滅火系統(tǒng)抗震設(shè)計(jì)(已修改)

2024-11-12 11:35 本頁面
 

【正文】 The Evolution of Seismic Design of Fire Sprinkler Systems Russell P. Fleming, . Executive Vice President National Fire Sprinkler Association Patterson, NY Special fire sprinkler system installation guidance intended to guard against damage due to earthquakes first appeared in the North American sprinkler installation standard in 1947, and was largely based on experience in the Long Beach earthquake of 1930. At that time many building codes in use in the United States did not even address the subject of earthquakes. Insurance reports of the Long Beach earthquake had indicated 90 damaged sprinkler systems. The first guidance, contained only in the appendix, called for 1 to 2 inches clearance around pipes, flexible couplings in risers and “some form of lateral and longitudinal bracing” for feed and cross mains. In the 1951 edition requirements were placed in the body of the standard for placement of longitudinal and lateral braces with spacing indicated as “30 to 40 ft”, a maximum slenderness ratio of brace members of 200, and flexible couplings on risers where it was necessary to protect systems against earthquakes. The stated intent was to laterally brace for 50% of weight of waterfilled piping and attachments. In the decades since then deliberate efforts have been made to clarify the rules and improve protection within the text of NFPA 13 – Installation of Sprinkler Systems, but always with the intent of addressing “how” systems are to be protected against earthquakes, not “where” such protection is to be provided. It was recognized that building codes and other authorities made the basic decisions with regard to the location of earthquakeprone areas. Although the earliest guidance contained in NFPA 13 came from the insurance industry in the western states, the NFPA Committee on Automatic Sprinklers formed an Earthquake Protection Submittee in 1985. One of the goals of this submittee was to develop a means to address the bracing of sprinkler systems in the same manner that the application of system hydraulics had been acplished. Although a plex subject, it was believed that many of the design aspects could be preengineered into tables and then properly applied by the technicians who normally lay out and detail fire sprinkler systems. The 1983 standard contained no information on the sizing or fastening of bracing relative to loads. A method was proposed in 1984 whereby “zones of influence” could be evaluated to determine total loads for proposed brace locations. Tables were proposed for determining maximum brace loads and allowable fastener loads based on six different binations of brace and fastener orientation and angle from vertical. This concept and the acpanying tables were accepted into the appendix of the standard in the 1987 edition, and in the 1989 edition the tables were expanded to nine binations of orientation and angle and moved into the body of the standard. 2020 Structures Congress: New Horizons and Better Practices 169。 2020 ASCE Copyright ASCE 2020 Structures Congress 2020 Downloaded 06 Mar 2020 to . Redistribution subject to ASCE license or copyright。 see NFPA 13 Earthquake Protection Submittee was in place at the time of the Loma Prieta and Northridge earthquakes in 1989 and 1994, and held public hearings in cooperation with the National Fire Sprinkler Association and the Society of Fire Protection Engineers following those events in order to evaluate how fire sprinkler systems performed during the earthquakes ands to develop suggestions for improvements to the protection criteria within the standard. In general, the performance of fire sprinkler systems in those earthquakes was judged to be good, with a strong correlationbetween observed failures and departures from the rules of NFPA 13. One area acknowledged to be in need of improvement was the interaction of sprinklers and ceilings。 impact of sprinklers against rigid ceilings resulted in a several highprofile incidents in which a number of sprinklers opened and water damage resulted. In 1999 the NFPA sprinkler project was reanized. Responsibilities for the earthquake protection rules were given to a new NFPA Technical Committee on Hanging and Bracing of WaterBased Fire Protection Systems, one of four separate technical mittees coordinated through a Technical Correlating Committee responsible for NFPA 13. This allowed the direct input of more earthquake engineering expertise into the standard development process. Major changes in building code requirements for earthquake protection have taken place in the past twenty years, mainly due to the National Earthquake Hazards Reduction Program (NEHRP) provisions developed with funding from the Federal Emergency Management NEHRP provisions initially found their way into the codes through direct adoption, and more recently through reference to the American Society of Civil Engineer’s standard ASCE/SEI 7. As a result, the goal of the mittee that prepares NFPA 13 has evolved during the years. From the original goal of independently providing a means of protecting sprinkler systems against earthquake forces,
點(diǎn)擊復(fù)制文檔內(nèi)容
公司管理相關(guān)推薦
文庫吧 www.dybbs8.com
公安備案圖鄂ICP備17016276號(hào)-1