freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

心率測試儀設計方案srtp結(jié)題論文(已修改)

2025-09-07 12:54 本頁面
 

【正文】 SRTP 結(jié)題論文 論文題目 心率測試儀設計方案 學 院 信息科學與工程學院 心率測試儀設計方案 一 目錄 論文題目 心率測試儀設計方案 ....................................................................................................................1 摘要、關鍵詞 .............................................................................................................................................. 二 第一章 緒論 ..........................................................................................................................................三 醫(yī)學常識 心率測試的意義 心率測試儀的組成框圖 心率測試的基本過程 第二章基礎知識介紹 ..............................................................................................................................五 SC0073 微型動態(tài)脈搏微壓傳感器 單片機介紹 RS232 協(xié)議串口通信 第三章電路設計方案 ......................................................................................................................... 十一 傳感器模塊方案選擇 濾波放大電路設計 比較整形電路設計 匹配電路設計 下位機的設計 第四章上位機設計方案 ..................................................................................................................... 十七 上位機設計目的 功能及要求 系統(tǒng)框圖 系統(tǒng)主界面設計 圖表分析功能 數(shù)據(jù)庫存儲功能 健康報告提示 第五章參考文獻 ............................................................................................................................. 二十五 第六章附錄 ...................................................................................................................................... 二十五 心率測試儀設計方案 二 心率測試儀設計方案 王晨 (東南大學 信息科學與工程學院 11 級 南京 211189) 摘要 本設計方案的主 要內(nèi)容是設計一個 由 信號采集 電路、 濾波 整形電路、計數(shù)顯示電路組成的 實時 心率 采集系統(tǒng)。 本系統(tǒng) MSP430F149 單片機為核心控制芯片,SC0073 微型 壓電 式脈搏波傳感器采集信號,經(jīng)信號處理電路后 將 脈沖 信號 送入單片機, 并在 12864 液晶顯示器上進行實時數(shù)據(jù)顯示。同時, 本設計采用 MSP430F149 作為下位機, PC 機作為上位機 —— 于 . 框架下利用 C語言開發(fā)的的心率測試儀控制系統(tǒng) ,通過 RS232 串口通信協(xié)議 將數(shù)據(jù)傳輸?shù)?PC 機上,我們可以方便地監(jiān)測測量參數(shù) 。本文設計的心率 測試 儀使用方便,只需將 傳感器輕靠動脈處 ,即可實時顯示出 心率。 該系統(tǒng)運行穩(wěn)定,實時性強,安全可靠,系統(tǒng)通用性好,移植、擴展方便,同時具有 低成本、低功耗、操作簡單等優(yōu)點, 對心血管疾病的早期診斷具有重要的意義。 【 關鍵詞 】 傳感器 濾波整形電路 串口通信 上位機設計 Abstract The maincontents of thisdesignis to design acircuitfrom thesignal acquisition, filtering shaping circuit, counting acquisition systemdisplays realtimeheart ratecircuitposed. This systemMSP430F149microcontroller as the corecontrol chip, SC0073 MicroPiezopulse wave sensorsignal acquisitionbythe pulse signalaftersignal processing circuitinto the microcontrollerandLCD displayon the12864realtime datadisplay. Meanwhile, the design uses MSP430F149as the next crew, PC machineas a PC—— under. Net frameworkusing C language developedheart ratetestercontrolsystem, viaRS232serial municationprotocolto transfer data toa PC,wecan easilymonitor themeasured parameter. This design ofthe heart ratetestereasy to use,simplybya lightsensorartery, heart ratecan bedisplayed in real time. Thesystem is stable,realtime,secure,systemversatility,easy totransplant,expansion, and low cost, lowpower consumption,easy operation, etc., has importantsignificance forthe early diagnosisof cardiovascular diseases. 【 Keywords】 Sensorfilter shape circuitdesign of serial munication between PC 心率測試儀設計方案 三 第一章 緒論 醫(yī)學常識 心率 (Heart Rate):用來描述心動周期的專業(yè)術(shù)語,是指心臟每分鐘跳動的次數(shù) ,以第一聲音為準。心電信號是一種非常弱且頻率較低的信號,一般幅值在~ 5mV,頻率在 ~ 100Hz。 結(jié)構(gòu)特征:心臟是一厚壁的肌性器官,由左右 2 心房和左右 2 心室 4 個心腔組成。心臟的自動節(jié)律性收縮,推動血液在循環(huán)系統(tǒng)的各種血管中環(huán)流,使機體各組織、器官能不斷地吐故納新、新陳代謝。 正常成年人安靜時的心率有顯著的個體差異,平均在 75 次 /分左右 (60— 100次 /分之間 )。心率可因年齡、性別及其它生理情況而不同。初生兒的心率很快,可達 130 次 /分以上。在成年人中,女性的心率一般比男性稍快。同一個人,在安靜或睡眠時心率減慢,運動時或情緒激動時心率加快,在某些藥物或神經(jīng)體液因素的影響下,會使心率發(fā)生加快或減慢。經(jīng)常進行體力勞動和體育鍛煉的人,平時心率較慢。 健康成人的心率為 60~ 100 次 /分,大多數(shù)為 60~ 80 次 /分,女性稍快; 3 歲以下的小兒常在 100 次 /分以上;老年人偏慢。成人每分鐘心率超過 100 次(一般不超過 160 次 /分)或嬰幼兒超過 150 次 /分者,稱為竇性心動過速。常見于正常人運動、興奮、激動、吸煙、飲酒和喝濃茶后。也可見于發(fā)熱、休克、貧血、甲亢、心力衰竭及應用阿托品、腎上腺素、麻黃素等。如果成人的心率在 160~220 次 /分,則稱為陣發(fā)性心動過速。心率低于 60 次 /分者(一般在 40 次 /分以上),稱為竇性心動過緩 [5]。可見于長期從事重體力勞動和運動員;病理性的見于甲狀腺 機能低下、顱內(nèi)壓增高、阻塞性黃疸、以及洋地黃、奎尼丁或心得安類藥物過量或中毒。如心率低于 40 次 /分,應考慮有房室傳導阻滯。心率過快超 過 160 次/分,或低于 40 次 /分,大多見于心臟病病人,病人常有心悸、胸悶、心前區(qū)不適,應及早進行詳細檢查,以便針對病因進行治療。心電圖如圖 11 所示 。 圖 11 心電圖 心率測試儀設計方案 四 脈搏波:人體心室周期性 的 收縮和舒張導致主動脈的收縮和舒張 ,使血流壓力以
點擊復制文檔內(nèi)容
黨政相關相關推薦
文庫吧 www.dybbs8.com
公安備案圖鄂ICP備17016276號-1