【正文】 ime for periodical emission of the Status object ON/OFF: h, min, s Emission of Status object during manual mode : Enabled, Disabled Time delay for emission of “ON/OFF Status” objects after bus power cut: h, min, s Output status during bus power cut: Unchanged, ON, OFF Output status at bus power return: Unchanged, ON, OFF Status during and after ETS download: Unchanged, ON, OFF Diagnosis object activation: Not used, used Emission of Diagnosis object: On change, Periodically, On change and periodically Time for periodical emission of the Diagnopsis object: h, min, s Basic functions Preset 1 Preset 2 Autorisation Preset 1 Autorisation Preset 2 Output status Scene Restore scene Diagnosis Erdal Y252。zer New Generation Step 1 21 調(diào)光模塊:參數(shù)詳解 1 Relative dimming speed: h, min, s Switch ON speed: h, min, s Cut OFF speed: h, min, s Brightness value at switch ON: 0…100 %, 101% = Last value Minimum dimming value: 1…50% Maximum dimming value: 51…100% Timer function activation: Not used, used Timer operation : Value %, Blinking Timer/toggle changeover activation: Not used, used Timer duration modifiable through object “Timer duration”: Enabled, Disabled Timer duration : h, min, s Tripping delay: Disabled, h, min, s Switching delay: Disabled, h, min, s CutOFF prewarning: Disabled, h, min, s CutOFF prewarning duration: h, min, s Timer interruption : Interruptible timer, Noninterruptible timer Timer retriggerable : Yes, No Timer duration extension: No limitation, 1 to 5 time duration extension Time limited toggle switch activation: Enabled, Disabled Time limited toggle switch duration: h, min, s Operating hours counter activation: Enabled, Disabled Relay status for operating hours counter: Normally closed, normally open Operating hours counter direction: Incremental counter, decremental counter Operating hours counter set point value: 1 … 65535 h Operating hours counter set point value modifiable through “Operating hours counter setpoint” object: Enabled, Disabled Emission of the “Operating hours counter value” object: Not used, periodically Time for periodical emission of the “Operating hours counter value” object: h, min, s Basic functions ON/OFF Timer Timer / Toggle changeover Time limited toggle switch Timer duration Hours counter value Hours counter setpoint Reset hours counter Hours counter setpoint reached Scene Restore scene Dimming Brightness value % Erdal Y252。zer New Generation Step 1 22 調(diào)光模塊:參數(shù)詳解 2 Duration of brightness value 1 during blinking function: h, min, s Brightness value 1 during blinking function : 0…100 %, 101% = Last value Dimming speed for Brightness value 1 during blinking function: 0…100 %, 101% = Last value Duration of brightness value 2 during blinking function: h, min, s Brightness value 2 during blinking function : 0…100 %, 101% = Last value Dimming speed for Brightness value 2 during blinking function: 0…100 %, 101% = Last value Output status emitted during Blinking function: ON, OFF, ON/OFF Preset function activation: Disabled, Preset 1Level, Preset 2Level Activation of Preset authorization objects: Yes, No Polarity of Preset 1/2 authorization object: 0 = not authorized。 1 = authorized 0 = authorized。 1 = not authorized Output status if preset object 1/2 = 1: Unchanged, Invert status, Value %, Scene X, Blinking, Status before Preset object =”0” Output status if preset object 1/2 = 0: Unchanged, Invert status, Value %, Scene X, Blinking, Status before Preset object =”1” Activation of Scene function: Enabled, Disabled Number of scenes displayed: 8, 16, 24, 32, 64 Status for Scene X : Value %, Blinking, Not concerned Brightness value for scene X: 0…100 %, 101% = Last value Dimming speed for scene X: h, min, s Scene memorization by long press on ambient push button: Enabled, Disabled Scene memorisation acknowledgment: Enabled, Disabled Restore ETSparameters settings object activation: Enabled, Disabled Overwrite of Scene, timer and operating hours counter value at next download: Enabled, Disabled Switching ON by long press: Enabled, Disabled Switching OFF by long press: Enabled, Disabled Basic functions Preset 1 Preset 2 Autorisation Preset 1 Autorisation Preset 2 Scene Restore scene Erdal Y252。zer New Generation Step 1 23 調(diào)光模塊:參數(shù)詳解 3 Status ON/OFF activation: Enabled, Disabled Polarity of Status object ON/OFF: 0 = OFF 。 1 = ON, 0 = ON 。 1 = OFF Emission of Status object ON/OFF: On change, Periodically, On change and periodically Time for periodical emission of the Status object ON/OFF: h, min, s Emission of Status object during manual mode : Enabled, Disabled Time delay for emission of “ON/OFF Status” objects after bus power cut: h, min, s Brightness value indication activation : Enabled, Disabled Emission of Brightness value indication object: On change, Periodically, On change and periodically Time for periodical emission of the of Brightness value indication object: h, min, s Emission of of Brightness value indication object during manual mode : Enabled, Disabled Time delay for emission of Brightness value indication object after bus power cut:: h, min, s Brightness value during bus power cut: Unchanged, 0…100 %, 101% = Last value Brightness value at bus power return: Unchanged, 0…100 %, 101% = Last v
點(diǎn)擊復(fù)制文檔內(nèi)容
物理相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1