【正文】
ard, the aircondition technology has been taken an abroad use, which built a healthy and fort habitation for people. The designs included the system of a certain hotel’s center aircondition in FuShun . The whole aircondition section was plotted according to the different functionregion, including: A. fan coils and the system of fresh air B. allair system C. microtomeceil air system The mainmachine and fan coils’ choice were based on the calculation of coldload. And through the numeration of blast volume and water flux, the standard of air duct and water pipe was determined. The most disadvantage resistance and pressure of the looproad were checked up to ensure the machine of freshair and water pump. According to the parameter which was offered by the correlate aircondition design handbook, the choice of freshair machine, water pump and the hot water machine was finished. Then the part of the sanitationhotwater was performed. At last, the whole design was shown on the drawing. Keyword: centeraircondition, load, lectotype, piprline design II 目 錄 摘要 ..................................................................................................................................I Abstract .............................................................................................................................I 第一章 工程概況 ............................................................................................................. 1 第二章 設(shè)計(jì)依據(jù) ............................................................................................................. 2 .......................................................... 2 ............................................................ 2 ............................................................ 2 ................................................................ 2 第三章 負(fù)荷計(jì)算 ............................................................................................................. 3 第四章 機(jī)組選型 ........................................................................................................... 15 ..................................................... 15 ............................................................. 18 ....................................................... 19 、送風(fēng)狀態(tài)的確定 ............................................. 22 ................................................... 27 .............................. 27 第五章 水系統(tǒng)設(shè)計(jì) ........................................................................................................ 37 ....................................................... 37 ................................................. 37 ............................................................. 37 ............................................................. 38 ............................................................... 38 ......................................................... 44 結(jié) 論 ........................................................................................................................ 48 參考文獻(xiàn) ........................................................................................................................ 49 致 謝 ........................................................................................................................ 50 1 第一章 工程概況 本設(shè)計(jì)為某賓館中央空調(diào)系統(tǒng)設(shè)計(jì),該賓館坐落在撫順市,總共為八層。 在冷負(fù)荷計(jì)算的基礎(chǔ)上完成主機(jī)和風(fēng)機(jī)盤(pán)管的選型,并通過(guò)風(fēng)量、水量的計(jì)算確定風(fēng)管路和水管路的規(guī)格 ,并 校 核最不利環(huán)路的阻力和壓頭用以確定新風(fēng)機(jī)和水泵。撫順某賓館中央空調(diào)系統(tǒng)設(shè)計(jì) 摘 要 隨著科學(xué)技術(shù)的發(fā)展以及人民生活水平的提高,空調(diào)技術(shù)的利用越來(lái)越廣泛,給人類(lèi)營(yíng)造了健康舒適的生活環(huán)境。 而本設(shè)計(jì)的內(nèi)容是撫順某賓館中央空調(diào)系統(tǒng),通過(guò)對(duì)不同功能區(qū)域進(jìn)行劃分,從而將整個(gè)空調(diào)區(qū)劃分為: a、風(fēng)機(jī)盤(pán)管加新風(fēng)系統(tǒng); b、全空氣處理系統(tǒng); c、超薄吊頂式空氣處理系統(tǒng)。 依據(jù)相關(guān)的空調(diào)設(shè)計(jì)手冊(cè)所提供的參數(shù),進(jìn)一步完成新風(fēng)機(jī)組、水泵、熱水機(jī)組等的選型,從而將其反應(yīng)在圖紙上,最終完成整個(gè)空調(diào)系統(tǒng)設(shè)計(jì)。其中首層為辦公及娛樂(lè)區(qū),二層為餐廳,三至八層為客 房。畢業(yè)設(shè)計(jì)要求完成整棟大樓的中央空調(diào)系統(tǒng)設(shè)計(jì)以及衛(wèi)生熱水集中供應(yīng)系統(tǒng)設(shè)計(jì)。 2 第二章 設(shè)計(jì)依據(jù) 設(shè)計(jì)規(guī)范及標(biāo)準(zhǔn) (GBJ500192021) ( GB/T50001- 2021) ( GBJ11488) 基本氣象參數(shù) 地理位置 : 遼寧 省 撫順市 夏季參數(shù) 大氣壓 : 99858Pa 室外計(jì)算干球溫度 : ℃ 空調(diào)日平均計(jì)算溫度 : ℃ 計(jì)算日較差 : ℃ 室外濕球溫度 : ℃ 室外平均風(fēng)速 : m/s 冬季參數(shù) 大氣壓: 101858pa 空調(diào)計(jì)算溫度: ℃ 室外相對(duì)濕度: % 室外平均風(fēng)速: m/s 室內(nèi)設(shè)計(jì)參數(shù),如表 21: 表 21 室內(nèi)設(shè)計(jì)參數(shù) 房間名稱(chēng) 夏 季 冬 季 溫度℃ 相對(duì)濕度 % 溫度℃ 相對(duì)濕度 % 客房 24~26 55~70 24~22 50~30 會(huì)議室、辦公室 25~27 55~70 23~20 40 走道、門(mén)廳 25~27 65 20~16 30 健身房 24 60 19 40 大堂吧、酒吧 26 60 23 40 宴會(huì)廳、餐廳 24~26 65 23~20 40 休閑娛樂(lè)區(qū) 25 60 21 40 設(shè)計(jì)原則 考慮到該賓館具有多種功能區(qū),故一層除健身房、大堂吧、酒吧、休息室采用超薄吊頂式空氣處理機(jī)組外,其余功能區(qū)域采用風(fēng)機(jī)盤(pán)管加新風(fēng);二層的宴會(huì)廳和特色餐廳采用組合式空氣處理機(jī)組集中送回風(fēng);三到七層的客房全部采用風(fēng)機(jī)盤(pán)管加新風(fēng);八層除了會(huì)議室和休閑區(qū)采用超薄吊頂式空氣處理機(jī)組外,剩余客房采用風(fēng)機(jī)盤(pán)管加新風(fēng)機(jī)組;走廊由每層的新風(fēng)系統(tǒng)單獨(dú)供新風(fēng)?!?) 對(duì)有內(nèi)遮陽(yáng)設(shè)施的玻璃窗,層玻璃窗 的 K值應(yīng)減小 25%,雙層玻璃窗的 K 值應(yīng)減小 15%; —— 玻璃窗的冷負(fù)荷計(jì)算溫度的逐時(shí)值,℃ 2). 玻璃窗日射得熱引起的冷負(fù)荷 式中: —— 玻璃窗的凈面積 , —— 玻璃窗的綜合遮擋系數(shù), —— 為玻璃窗的遮擋系數(shù), —— 為窗內(nèi)遮陽(yáng)設(shè)施的遮陽(yáng)系數(shù) 。 3). 有外遮陽(yáng)玻璃窗的日射負(fù)荷為: (1). 玻璃日射有外遮陽(yáng)時(shí)可減少 得熱量近 80%。 人體散濕形成的潛熱冷負(fù)荷 —— 一 名成年男子小時(shí)潛熱散熱量 , W。11()d a pt t t K K? ? ? ?1qTX??2Q n q?? ? ?2q1tTQ n q X?? ?? ? ? ?t s TQ q X????TX??sq()cL NC,()Jmzx ND 5 —— 熱源的實(shí)際散熱量, W。 7. 照明 1).白熾燈和鎮(zhèn)流器在空調(diào)房間外的熒光燈 2). 鎮(zhèn)流器裝在空調(diào)房間內(nèi)的熒光燈 3). 暗裝在吊頂玻璃罩內(nèi)的熒光燈 N —— 照明設(shè)備的安裝功率, kW —— 考慮玻璃反射,頂棚內(nèi)通風(fēng)情況的系數(shù),當(dāng)熒光燈罩有小孔, 利用 自然通風(fēng)散熱于頂棚內(nèi)時(shí),取為 ~ ,熒光 燈罩無(wú)通風(fēng)孔時(shí),視頂棚內(nèi)通風(fēng)情況取為 ~ ; —— 同時(shí)使用系數(shù),一般為 ~ ; T—— 開(kāi)燈時(shí)刻 ,點(diǎn)鐘 τ T—— 從開(kāi)燈時(shí)刻到計(jì)算時(shí)刻的時(shí)間, h; —— τ T 時(shí)間照明散熱的冷負(fù)荷系數(shù) 8. 滲透空氣 1). 滲透空氣的顯熱冷負(fù)荷 1 2 3 41000sq n n n n N? ? ? ? ? ?11000sq n N?? ? ? ?11 0 0 0 (1 )sq n N??? ? ? ? ? ?11000sq n N??? ? ? ? ?1n2n4nTXNnQ ????? ?? 11 0 0 0TXNnQ ????? ?? 11200TXNnnQ ?????? ?? 011 0 0 00n1n)( nw ttGQ ????TX?? 6 G—— 單位時(shí)間滲入室內(nèi)的總空氣量, kg/h。 —— 夏季空調(diào)室外干球溫度 下的空氣密度 , (2). 通過(guò)房間門(mén)、窗滲入空氣量