【正文】
1 6 Priority ?S? or ?R? 1 Y 7 Requested/Ordered Date and Time ?YYYYMMDD HHMMSS? 14 Y 16 Specimen Descriptor 1=Serum 2=Urine 3=Plasma 4=Gastric juice 5=Ascites 6=CSF 7=Other 1 Y 26 Report Types ‘ O’ , ‘ F’ , ‘ I’ , ‘ C’ or ?X? 1 Y Result Record (R) Description: The Result Record to the host contains the result of a single analytical determination. Example: STXFNR|1|^^^GGT||mg/dL|3^12\0^20|N||F||||20202024151012 CRETXCheckSumCRLF Field No. E 1394 ASTM Field Name Field Contents Max Length Mandatory 1 Record Type ID R 1 Y 2 Sequence Number 5 Y 3 Universal Test ID 10 Y 4 Data or Measurement Value 12 N 5 Units 10 N 6 Reference Ranges first range = normal range second range = critical range separated by repeat delimiter (39。 37 26h 4. Table of Record Message Type Record Name Identifier Message Header Record H Patient Information Record P Test Order Record O Result Record R Message Terminator Record L Request Information Record Q 5. Communication mode CS800 is able to municate in realtime mode or batch mode. Realtime Mode: The instruments identifies a sample identification or a Disk/position identification and asks the host for test selections. Results will be uploaded as soon as available and/or as manually selected from the result data base. Batch Mode: Results will be uploaded as soon as available and/or as manually selected from the result data base. 6. Sample No. and ID Modes The analyzer can be operated in one of two modes for identifying samples: 1. Sample No. Mode 2. ID Mode The most mon mode used is ID Mode, which has provisions for processing samples that have damaged, unreadable or missing barcode labels. The user can switch between ID Mode and Sample Number Mode during standby without clearing the database, but switching is not remended. Generally, once a mode is decided upon, it is rarely changed. Sample No. Mode In this mode, the barcode reader is turned off. Samples are tracked by an internal sample number that increments sequentially as samples are processed, and also by the Disk ID and position number. The sample number mode requires the operator to either load the analyzer by using a load list generated by the host system, or make test selections manually on the analyzer. ID Mode This is a random mode that allows barcoded samples to be placed on the system in any order. In ID Mode, samples without barcodes and samples with damaged or unreadable barcodes can be processed by a manual setting. The ID mode is applicable for both routine and Stat samples. 7. Communication Options Host munication options can be found on the System Setup/Host Communication Setting/ Communication Setting screen. Default :19200,8,N,1. Item Specifications Com Port 1~4 Baud rate 4800,9600,19200 data bit 7,8 Parity bit Even, Odd, None Stop bit 1,2 8. Retry Times Out Enter Range : 1 15 (Second) 9. Retry Count Enter Range: 1 6 (Count) 9. Data Record Usage (refer to ASTM 1394, particularly sections 6 through 13) Each record sent by the CS800 will contain up to the last field used by the CS800, which may or may not be all fields possible for the record. The first Max Length characters are significant more characters transmitted for a specific field are ignored. Message send from CS800 to Host