【正文】
辦公室]2008[過道]2009[廠 部 中 心]3層3007[會(huì) 議 室]3008[展 廳]3009[會(huì) 議 室]3010[會(huì) 議 室]3011[展 廳]3012[展 廊]3013[會(huì)議室下]4層4001[公司分部]4002[公司分部]4003[總部中心]4004[總部中心下]4005[休息廊]4006[公司分部]4007[公司分部]5層開敞式辦公室副總經(jīng)理室總經(jīng)理室總經(jīng)理室下副總經(jīng)理室7537休息廊6層電教室培訓(xùn)中心[中庭上空]培訓(xùn)室培訓(xùn)室電教室休息廊60141號(hào)樓 各房間送風(fēng)方式的確定個(gè)房間采用風(fēng)機(jī)盤管加新風(fēng)系統(tǒng),風(fēng)機(jī)盤管的新風(fēng)供給方式用單設(shè)新風(fēng)系統(tǒng),獨(dú)立供給室內(nèi)。冬季新風(fēng)冷負(fù)荷:(kW) (415)其中:——冬季新風(fēng)冷負(fù)荷,kW;——新風(fēng)量,kg/s;——空氣比熱容,kJ/kg/h?人。n/W (413)式中:Q6——人體散熱形成的冷負(fù)荷,W;qs——不同室溫和勞動(dòng)性質(zhì)成年男子顯熱散熱量,W(見表120[1]);n——室內(nèi)全部人數(shù);n/——群集系數(shù),;CLQ——人體顯然散熱冷負(fù)荷系數(shù),人體顯然散熱冷負(fù)荷系數(shù)(見表121[1])。CLQ +qln電子設(shè)備散熱量計(jì)算公式同(410),其中系數(shù)n2的值根據(jù)使用情況而定。n4n2(2)電熱設(shè)備散熱量對(duì)于無保溫密閉罩的電熱設(shè)備,按下式計(jì)算:Q=1000n3n1n3n1n3n1CLQ(W) (48)式中:Q7——設(shè)備和用具實(shí)際的顯熱形成的冷負(fù)荷,W;Qq——設(shè)備和用具的實(shí)際顯熱散熱量,W;CLQ——設(shè)備和用具顯熱散熱冷負(fù)荷系數(shù);如果空調(diào)系統(tǒng)不連續(xù)運(yùn)行,則CLQ=。由表118[1]查得;CLQ ——冷負(fù)荷系數(shù),由表119(a)~表119(b)[1]查得。CLQ(W) (47)式中:F——玻璃窗的凈面積,是窗口面積乘以有效面積系數(shù)Ca, C Z——玻璃窗的綜合遮擋系數(shù)C Z=CsC Zk);tl——玻璃窗的冷負(fù)荷溫度逐時(shí)值,℃,見表113[1];tn——室內(nèi)設(shè)計(jì)溫度,℃。;K——玻璃的傳熱系數(shù),W/(m178。K℃ (44)式中:t ——夏季空調(diào)房間室外計(jì)算日平均溫度,℃;tl s ——相鄰非空調(diào)房間的平均計(jì)算溫度與夏季空調(diào)房間室外計(jì)算日平均溫度的差值,當(dāng)相鄰散熱量很少(如走廊)時(shí), tl s 取3 ℃,;當(dāng)相鄰散熱量在23~116 W /m2時(shí), tl s取5 ℃。(tl s tn)W (43)式中:F——內(nèi)維護(hù)結(jié)構(gòu)的傳熱面積,m178。kp(℃) (42)式中:td——地區(qū)修正系數(shù),℃,見表1-8(a)及表1-8(b)[1];ka——不同外表面換熱系數(shù)修正系數(shù),見表19[1];kp——不同外表面的顏色系數(shù)修正系數(shù),見表110[1];當(dāng)空調(diào)房間的溫度與相鄰非空調(diào)房間的溫度大于3℃時(shí),要考慮由內(nèi)維護(hù)結(jié)構(gòu)的溫差傳熱對(duì)空調(diào)房間形成的瞬時(shí)冷負(fù)荷,可按如下傳熱公式計(jì)算:Q2=F必須指出式(41)中的各圍護(hù)結(jié)構(gòu)的冷負(fù)荷溫度值都是以天津地區(qū)氣象參數(shù)為依據(jù)計(jì)算出來的,因此對(duì)不同地區(qū)和不同情況應(yīng)按下式進(jìn)行修正: t39。(tlntn)(W) (41)式中:Q1——外墻和屋面瞬變傳熱引起的逐時(shí)冷負(fù)荷,W; F——外墻和屋面的面積,m178。第 66 頁 共 70 頁第3章 負(fù)荷計(jì)算在日射和室外氣溫綜合作用下,外墻和屋面瞬變傳熱引起的逐時(shí)冷負(fù)荷可按下式計(jì)算: Q=F空調(diào)使用時(shí)間:辦公樓空調(diào)每天使用10小時(shí),即8:00~18:00。照明、設(shè)備:由建筑電氣專業(yè)提供,照明設(shè)備為暗裝熒光燈,鎮(zhèn)流器設(shè)置在頂棚內(nèi),熒光燈罩無通風(fēng)孔,功率為30W/m178。/h/h二、三、四、五、六層房間結(jié)構(gòu)基本相同:由開敞式辦公室,會(huì)議室,展廳等房間組成,共30間。,二、三、四、五、總建筑高度約為22m。房間類型包括:開敞式辦公室,會(huì)議室,接待廳,接待大廳,商務(wù)中心,咖啡廳,貴賓室,展廳,總部中心,公司分部,副總經(jīng)理室,總經(jīng)理室,培訓(xùn)室,電教室,培訓(xùn)中心。1≤6520本設(shè)計(jì)是廣州市某辦公樓中央空調(diào)系統(tǒng)設(shè)計(jì)。1≤6520電教室26177。1≤6550總經(jīng)理室26177。1≤6530公司分部26177。1≤6530會(huì)議室26177。1≤6530開敞式辦公室26177。1≤6530商務(wù)中心、咖啡廳26177。/)接待大廳26177。夏季:空調(diào)室外計(jì)算干球溫度:33℃;通風(fēng)室外計(jì)算干球溫度:29℃;空調(diào)室外計(jì)算濕球溫度:℃;通風(fēng)室外計(jì)算相對(duì)濕度:70%;,風(fēng)向ESE,頻率12%;大氣壓力:;表31夏季室內(nèi)參數(shù)表名稱溫度176。59′,東經(jīng)117176。所以在設(shè)計(jì)階段要對(duì)方案進(jìn)行充分的論證。整個(gè)設(shè)計(jì)中盡力能完善的解決工程中的實(shí)際常見問題。比如管路的腐蝕問題,保溫問題。本設(shè)計(jì)內(nèi)容包括:負(fù)荷計(jì)算;風(fēng)系統(tǒng)設(shè)計(jì);水系統(tǒng)設(shè)計(jì);機(jī)房布置;設(shè)備選型說明書撰寫及文獻(xiàn)翻譯幾部分。這個(gè)過程就是方案在成熟完善并且檢驗(yàn)的過程。繪圖中要盡量的與工程中實(shí)際問題的解決相聯(lián)系。整個(gè)設(shè)計(jì)的理論部分主要集中在前兩個(gè)部分,實(shí)際的安裝和設(shè)備運(yùn)行等實(shí)際性的工程問題都集中在繪圖這個(gè)階段。空調(diào)方案的選擇決定了后期設(shè)計(jì)的方向和內(nèi)容,是設(shè)計(jì)中關(guān)鍵的環(huán)節(jié)??照{(diào)系統(tǒng)方案的選擇,基本上確定了空調(diào)的形式和內(nèi)容。送風(fēng)量和管路的計(jì)算是面向?qū)嶋H設(shè)備和管路的數(shù)據(jù)資料。是確定室內(nèi)空調(diào)調(diào)節(jié)方案的主要數(shù)據(jù)。設(shè)計(jì)計(jì)算主要有冷負(fù)荷的計(jì)算,送風(fēng)量的計(jì)算,管路的計(jì)算等。其中,有理論的分析計(jì)算,有中央空調(diào)方案的選擇論證,有實(shí)際的繪圖安裝。各個(gè)部分都要保證科學(xué)合理,正確無誤,經(jīng)濟(jì)適用。計(jì)算部分是整個(gè)設(shè)計(jì)的基礎(chǔ),繪圖部分是與設(shè)計(jì)施工相聯(lián)系的實(shí)際的走管和安裝。從使用性到科學(xué)性再到經(jīng)濟(jì)性上做到好的結(jié)合。從冷負(fù)荷計(jì)算,到室內(nèi)方案的選擇和設(shè)備的選型。能夠有效的管理,一次性投資,后期使用方便,并且不占用建筑的有效空間。并能對(duì)以后的使用和費(fèi)用支出做一定的預(yù)估。從建筑結(jié)構(gòu)及其甲方要求制定空調(diào)方案,要求能夠滿足使用的要求,即能夠滿足辦公舒適性。 the plan of the insulation of air duct and chilled water pipes。 the estimation of air distribution method and the selection of relevant equipments。. The height of the first floor is meters,and the other three floor’heights are all meters. The aircondition system is designed to supply cool air in summer, and a fan coil units (FCUs)fresh air system is selected and central screw water chillers are used to provide the chilling water needed. In winter, the municipal central heating system is used to supply heat and keep official room warm. Some of the main points in this design are given as follows: To design an appropriate airconditioning system for the building, the overall analysis is important. This includes the calculation, such as cooling load calculation, the estimation of system zoning。需要結(jié)合所選擇的空調(diào)系統(tǒng)的特點(diǎn)及辦公樓的建筑結(jié)構(gòu)選擇合適的空調(diào)機(jī)組及末端設(shè)備,合理的布置吊頂內(nèi)風(fēng)管與水管的位置。設(shè)計(jì)的內(nèi)容包括:選定合適空調(diào)系統(tǒng)的類型并確定設(shè)計(jì)方案,計(jì)算部分也十分重要,例如:空調(diào)冷負(fù)荷的計(jì)算;空調(diào)系統(tǒng)的劃分與系統(tǒng)方案的確定;冷源的選擇;風(fēng)系統(tǒng)的設(shè)計(jì)與計(jì)算;室內(nèi)送風(fēng)方式與氣流組織形式的選定;水系統(tǒng)的設(shè)計(jì)、布置與水力計(jì)算; 風(fēng)管系統(tǒng)與水管系統(tǒng)保溫層的設(shè)計(jì)等內(nèi)容。要求采用空調(diào)夏季制冷。中央空調(diào)畢業(yè)設(shè)計(jì)冷水機(jī)組辦公樓中央空調(diào)設(shè)計(jì)摘要:本設(shè)計(jì)為廣州市XX公司辦公樓中央空調(diào)系統(tǒng),擬為之設(shè)計(jì)合理的中央空調(diào)系統(tǒng),為室內(nèi)工作人員提供舒適的工作環(huán)境。建筑共六層,178。設(shè)計(jì)的空調(diào)系統(tǒng)采用風(fēng)機(jī)盤管—新風(fēng)系統(tǒng),選用水冷機(jī)組制冷凍水供冷。除此之外,還需要進(jìn)行空調(diào)末端處理設(shè)備及機(jī)房輔助設(shè)備及的選型。并根據(jù)所選擇的空調(diào)機(jī)組選配合適的輔助設(shè)備:冷凍水循環(huán)水泵,冷卻水循環(huán)水泵,開式水箱,冷卻水塔,及相應(yīng)的水管風(fēng)管閥門等關(guān)鍵詞:辦公樓 中央空調(diào) 水冷機(jī)組 風(fēng)機(jī)盤管—新風(fēng)系統(tǒng)1廣東交通職業(yè)技術(shù)學(xué)院 制冷專業(yè)畢業(yè)設(shè)計(jì)THE CENTRAL AIRCONDITION OFOFFICIAL BUILDINGABSTRACT:The design of central airconditioning system for the building of a Guangzhou pany is aimed to get a fortable working condition indoors. The total area of the building is m178。 the design of air duct system and calculation。 the design of water system and the analysis of its resistance losses。 etc.. Meanwhile, equipment selection is also an essential part of the design. According to the requirement, a fan coil units (FCUs)fresh air system is appropriate. Thus,the main process equipment, . the chiller, the fan coil units, the circulating water pumps, the cooling tower, are also determined in the design considering their characteristics and working conditions.KEY WORDS: official building, central air conditioning cooling water chillerfan coil units (FCUs)fresh air system 第1章 設(shè)計(jì)說明本篇文章是對(duì)廣州某辦公樓中央空調(diào)的設(shè)計(jì)計(jì)算說明。此外還要從空調(diào)設(shè)計(jì)的科學(xué)合理性和經(jīng)濟(jì)性,以及建筑整體的美觀度考慮。中央空調(diào)在現(xiàn)代建筑中越來越多的應(yīng)用,技術(shù)也越來越成熟先進(jìn)。本文就是對(duì)中央空調(diào)的設(shè)計(jì)到選型,到校核計(jì)算的一個(gè)說明。機(jī)組的布置連接和選型都有說明。方案選擇是整體考慮以及設(shè)計(jì)的總體思想。三個(gè)部分相依相承,都與整個(gè)工程密不可分。本設(shè)計(jì)是真實(shí)性課題的典例。是一個(gè)完整的工程設(shè)計(jì)實(shí)例。冷負(fù)荷的計(jì)算確定了各個(gè)房間的空氣狀況和調(diào)節(jié)條件,以及整個(gè)工程的負(fù)荷量。也是選擇冷水機(jī)組最主要的參考數(shù)據(jù)。都是整個(gè)設(shè)計(jì)的基礎(chǔ)。本設(shè)計(jì)選用的是半集中的空調(diào)水系統(tǒng),獨(dú)立新風(fēng)加風(fēng)機(jī)盤管系統(tǒng)。也是綜合各個(gè)方面的因素制定出來的。繪圖是把方案完好的實(shí)現(xiàn)的一個(gè)基礎(chǔ),是工程賴以完成的技術(shù)性支持的資料。盡量使方案以一種直觀詳盡的方式體現(xiàn)出來。是整個(gè)設(shè)計(jì)中最重要和最有難度的部分。在上面主要階段完成以后還要對(duì)一些具體細(xì)節(jié)的問題加以論證思考并列出解決方案。材料的選擇問題等。然后就是方案的驗(yàn)證試用,一般中央空調(diào)的投資大,必須力求避免設(shè)計(jì)上帶來的后期問題。第2章 氣象參數(shù)采用廣州市花都區(qū)室外氣象參數(shù),氣象臺(tái)站位置:北緯38176。43′。C相對(duì)濕度%新風(fēng)量(m179。1≤6520接待廳26177。1≤6530貴賓室26177。1≤6520展廳26177。1≤6520總部中心26177。1≤6520副總經(jīng)理26177。1≤6550培訓(xùn)室26177。1≤6520培訓(xùn)中心26177。該辦公樓共六層,178。機(jī)房置于辦公建筑樓頂