35kv變電站繼電保護(hù)設(shè)計(jì)(留存版)

  

【正文】 ailure. It allows utilities and industrial customers to easily expand from a single puter to a full system, without reengineering.the directional protection basisEarly attempts to improve powerservice reliability to loads remote from generation led to the dualline concept. Of course, it is possible to build two lines to a load, and switch the load to whichever line remains energized after a disturbance. But better service continuity will be available if both lines normally feed the load and only the faulted line is tripped when disturbances occur. shows a singlegenerator, twoline, singleload system with breakers properly arranged to supply the load when one line is faulted. For the arrangement to be effective it is necessary to have the proper relay application. Otherwise, the expensive power equipment will not be able to perform as planned. Consider the application of instantaneous and/or time delay relays on the four breakers. Obviously the type of the relay cannot coordinate for all line faults. For example, a fault on the line terminals of breaker D. D tripping should be faster than B, however, the condition reverses and B should be faster than D. It is evident that the relay protection engineer must find some characteristic other than time delay if relay coordination is to be achieved.The magnitude of the fault current through breakers B and D is the。這次畢業(yè)設(shè)計(jì)由于資料不夠,所以我們多人一組共享資源,這無(wú)意是對(duì)我們的相互協(xié)作能力的考驗(yàn),在遇到一個(gè)人不能解決的問(wèn)題時(shí),我們共同商量,找到解決的方法。② 煉鐵廠、配電所:1) 躲配變低壓側(cè)母線最大三相短路電流,具體做法是選擇一個(gè)最大容量配變,如有多個(gè)最大容量配變則選擇距出線斷路器最近者。3) 第一段的靈敏性通常用保護(hù)范圍的大小來(lái)衡量,根據(jù)本設(shè)計(jì)的數(shù)據(jù),按線路首端(d1點(diǎn))短路時(shí)的最小短路電流校驗(yàn)靈敏系數(shù)。 對(duì) 35~63kV 線路,可按下列要求裝設(shè)相間短路保護(hù)裝置:1) 對(duì)單側(cè)電源線路可采用一段或兩段電流速斷或電流閉鎖電壓速斷作主保護(hù),并應(yīng)以帶時(shí)限過(guò)電流保護(hù)作后備保護(hù)。2) 靈敏度按保護(hù)范圍末端短路進(jìn)行校驗(yàn)。由于35 kV側(cè)二次電流大,因此以35kV側(cè)為基本側(cè)。后備保護(hù)不僅可以起到當(dāng)主保護(hù)應(yīng)該動(dòng)作而未動(dòng)作時(shí)的后備,還可以起到當(dāng)主保護(hù)雖已動(dòng)作但最終未能達(dá)到切除故障部分的作用。但實(shí)際上由于變壓器的勵(lì)磁涌流、接線方式及電流互感器誤差等因素的影響,繼電器中存在不平衡電流,變壓器差動(dòng)保護(hù)需解決這些問(wèn)題,方法有:①靠整定值躲過(guò)不平衡電流②采用比例制動(dòng)差動(dòng)保護(hù)。① 變壓器的外部故障常見的是高低壓套管及引線故障,它可能引起變壓器出線端的相間短路或引出線碰接外殼。3)在設(shè)計(jì)屋外高壓配電裝置時(shí),需按短路條件校驗(yàn)軟導(dǎo)線相間和相對(duì)地安全距離。 負(fù)荷計(jì)算的方法負(fù)荷計(jì)算的方法有需要系數(shù)法、利用系數(shù)法及二項(xiàng)式法等幾種。這種外橋式適用于電源線路較短而變電所負(fù)荷變動(dòng)較大、適用經(jīng)濟(jì)運(yùn)行需經(jīng)常切換的總降壓變電所。6) 6~10kV固定式配電裝置的出線側(cè),在架空線路或有反饋可能的電纜出線回路中,應(yīng)裝設(shè)線路隔離開關(guān)。它的接線方式能反映正常和事故情況下的供送電情況。2 設(shè)計(jì)概述1) 繼電保護(hù)設(shè)計(jì)任務(wù)書。整定計(jì)算一般包括動(dòng)作值的整定、靈敏度的校驗(yàn)和動(dòng)作時(shí)限的整定三部分。6) 。 1) 當(dāng)滿足運(yùn)行要求時(shí),應(yīng)盡量少用或不用斷路器,以節(jié)省投資。多數(shù)情形中,分段數(shù)和電源數(shù)相同。一般取啟動(dòng)電流上午周期分量作為計(jì)算電壓損失、電壓波動(dòng)和電壓下降以及選擇電器和保護(hù)元件等的依據(jù)。公式依據(jù)為: ()式中:Qc—需要補(bǔ)償?shù)臒o(wú)功容量,kvar;P30——全企業(yè)的有功計(jì)算負(fù)荷,kW;α—平均負(fù)荷系數(shù),~;qc——補(bǔ)償率,kvar / kW,查閱相關(guān)工程手冊(cè),可以得出qc=: ()故需要補(bǔ)償容量為1700kvar,選擇兩臺(tái)容量850 kvar的電容器并列補(bǔ)償運(yùn)行。 短路電流計(jì)算的方法,常用的有歐姆法(有稱有名單位制法)和標(biāo)幺制法(又稱相對(duì)單位制法)本設(shè)計(jì)采用標(biāo)幺制法進(jìn)行短路計(jì)算SB=100MVA,UB=Uav即:35kV側(cè)UB1=37kV,10kV側(cè)UB2=。2) 10kV線路過(guò)電流保護(hù):是利用短路時(shí)的電流比正常運(yùn)行時(shí)大的特征來(lái)鑒別線路發(fā)生了短路故障,其動(dòng)作的選擇性由過(guò)電流保護(hù)裝置的動(dòng)作具有適當(dāng)?shù)难訒r(shí)來(lái)保證,有定時(shí)限過(guò)電流保護(hù)和反時(shí)限過(guò)電流保護(hù);本設(shè)計(jì)與電流速斷保護(hù)裝置共用兩組電流互感器,采用二相二繼電器的不完全星形接線方式,選用定時(shí)限過(guò)電流保護(hù),作為電流速斷保護(hù)的后備保護(hù),來(lái)切除電流速斷保護(hù)范圍以外的故障,其保護(hù)范圍為本線路全部和下段線路的一部分。①主保護(hù)和后備保護(hù):35kV供電系統(tǒng)中的電氣設(shè)備和線路應(yīng)裝設(shè)短路故障保護(hù)。~, cm2。繼電器的實(shí)際動(dòng)作電流 A ()保護(hù)裝置的實(shí)際動(dòng)作電流 ()平衡線圈計(jì)算匝數(shù) (匝) ()故,取平衡線圈實(shí)際匝數(shù) ()工作線圈計(jì)算匝數(shù) (匝) () (),取法合適,不需重新計(jì)算。對(duì)單側(cè)電源帶電抗器的線路, 當(dāng)其斷路器不能切斷電抗器前的短路時(shí),不應(yīng)裝設(shè)電流速斷保護(hù),此時(shí),應(yīng)由母線保護(hù)或其 它保護(hù)切除電抗器前的故障。電流速斷保護(hù)(也稱為Ⅰ段)動(dòng)作時(shí)間短,速動(dòng)性好,但其動(dòng)作電流較大,某些情況下不能保護(hù)線路全長(zhǎng);限時(shí)電流速斷保護(hù)(也稱為Ⅱ段)有較短的動(dòng)作時(shí)限,而且能保護(hù)線路全長(zhǎng),卻不能作為相鄰線路的后備保護(hù);定時(shí)限過(guò)電流保護(hù)(也稱為Ⅲ段)的動(dòng)作電流較前兩段小,保護(hù)范圍大,既能保護(hù)本線路全長(zhǎng)又能作為相鄰線路的后備保護(hù)。繼電器的動(dòng)作電流為: ()考慮到系統(tǒng)發(fā)展時(shí)仍能適應(yīng),選用DL11/50型電流繼電器,~50A,故動(dòng)作電流整定值為30A。8 結(jié) 論在畢業(yè)設(shè)計(jì)三個(gè)月的時(shí)間里,我不僅將大學(xué)里學(xué)習(xí)的專業(yè)知識(shí)全部溫習(xí)了一遍,而且還深入的學(xué)習(xí)了很多新的繼電保護(hù)知識(shí),做出了一些相應(yīng)的成果,并在這過(guò)程中我學(xué)到了很有有效的學(xué)習(xí)方法和思考方法。特別是景老師淵博的學(xué)識(shí)、實(shí)事求是的工作作風(fēng)和對(duì)待問(wèn)題精益求精的學(xué)術(shù)態(tài)度使我受益非淺,使我逐漸培養(yǎng)起嚴(yán)謹(jǐn)細(xì)心的學(xué)習(xí)作風(fēng)。最后,我要感謝此次我們畢業(yè)設(shè)計(jì)的指導(dǎo)老師景展,她每次都很及時(shí)的在我們?cè)O(shè)計(jì)進(jìn)入一個(gè)新階段時(shí),及時(shí)的給我們做一些必要的指導(dǎo),并給我們提供了寬松的環(huán)境,使得我們?cè)跁r(shí)間上有很大的靈活性。 過(guò)電流保護(hù)的整定① 織布廠、膠木廠、印染廠1) 過(guò)電流保護(hù)又稱為電流保護(hù)III段,其整定原則為躲過(guò)最大的負(fù)荷電流,其動(dòng)作電流為: () () ()式中 ——最大的負(fù)荷電流。3) 過(guò)電流保護(hù)應(yīng)分別按本線路末端(d2點(diǎn))及下一線路末端(d3點(diǎn))短路時(shí)的最小短路電流校驗(yàn)靈敏系數(shù)。 線路保護(hù)的原理:1) 10kV線路電流速斷保護(hù):是根據(jù)短路時(shí)通過(guò)保護(hù)裝置的電流來(lái)選擇動(dòng)作電流的,以動(dòng)作電流的大小來(lái)控制保護(hù)裝置的保護(hù)范圍;有無(wú)時(shí)限電流速斷和延時(shí)電流速斷,采用二相二電流繼電器的不完全星形接線方式,本設(shè)計(jì)選用無(wú)時(shí)限電流速斷保護(hù)。7 線路保護(hù)整定計(jì)算 概述根據(jù)《電力裝置的繼電保護(hù)和自動(dòng)裝置設(shè)計(jì)規(guī)范GB5006292》可知:3~63kV 中性點(diǎn)非直接接地電力網(wǎng)中線路的保護(hù) 3~63kV 線路的下列故障或異常運(yùn)行,應(yīng)裝設(shè)相應(yīng)的保護(hù)裝置: 1) 相間短路; 2) 單相接地; 3) 過(guò)負(fù)荷。代入數(shù)據(jù)得: ()2) 躲過(guò)變壓器空載投入或外部故障后電壓恢復(fù)時(shí)的勵(lì)磁涌流 ()式中:Kk—可靠系數(shù),; Ie—變壓器額定電流:代入數(shù)據(jù)得: ()3) 躲過(guò)電流互改器二次回路短線時(shí)的最大負(fù)荷電流 ()式中: Kk—可靠系數(shù),; Idz1—正常運(yùn)行時(shí)變壓器的最大負(fù)荷電流;采用變壓器的額定電流。 輕瓦斯保護(hù)的動(dòng)作于信號(hào)的輕瓦斯部分,通常按產(chǎn)生氣體的容積整定:對(duì)于容量為10MVA以上的變壓器,整定容積為250~300cm2 。但是如果單臺(tái)運(yùn)行的變壓器容量在10000kV變壓器為變電所的核心設(shè)備,根據(jù)其故障和不正常運(yùn)行的情況,從反應(yīng)各種不同故障的可靠、快速、靈敏及提高系統(tǒng)的安全性出發(fā),設(shè)置相應(yīng)的主保護(hù)、異常運(yùn)行保護(hù)和必要的輔助保護(hù)如下:1) 主保護(hù):瓦斯保護(hù)(以防御變壓器內(nèi)部故障和油面降低)、縱聯(lián)差動(dòng)保護(hù)(以防御變壓器繞組、套管和引出線的相間短路)。接著,按所選擇的短路計(jì)算點(diǎn)繪出等效電路圖,并計(jì)算電路中各主要元件的阻抗。這種計(jì)算方法更具客觀性和普遍性,適用于各種類型負(fù)荷的計(jì)算,所求得的結(jié)果更接近實(shí)際。 35kV變電所主接線簡(jiǎn)圖綜上所述:本次設(shè)計(jì)采用一、二次側(cè)均為單母分段總降壓變電所這種接線 35kV變電所主接線圖 負(fù)荷計(jì)算 負(fù)荷計(jì)算的內(nèi)容和目的1) 計(jì)算負(fù)荷又稱需要負(fù)荷或最大負(fù)荷。、二次側(cè)均采用單母線分段的總降壓變電所主電路圖單母分段接線:即用分段斷路器或分段隔離開關(guān)將母線分成若干段。盡量做到年運(yùn)行費(fèi)小,包括電能損耗。 35kV系統(tǒng)原理接線圖3) 變電站10kV側(cè)母線負(fù)荷情況 10kV母線側(cè)負(fù)荷情況負(fù) 荷名 稱最大負(fù)荷(kW)功 率因 數(shù)導(dǎo) 線型 號(hào)線路電抗標(biāo)幺值回路數(shù)供 電方 式線路長(zhǎng)度(km)織布廠1200LGJ351架空線8膠木廠1200LGJ351架空線8印染廠1200LGJ351架空線8配電所1600LGJ351架空線10煉鐵廠1700LGJ351架空線104) BB2主變?nèi)萘?、型?hào)為6300kVA之SF16300/35型雙卷變壓器,YΔ/11之常規(guī)接線方式,具有帶負(fù)荷調(diào)壓分接頭,可進(jìn)行有載調(diào)壓。對(duì)繼電保護(hù)裝置的基本要求有四點(diǎn):即選擇性、靈敏性、速動(dòng)性和可靠性。繼電保護(hù)的未來(lái)發(fā)展,繼電保護(hù)技術(shù)未來(lái)趨勢(shì)是向計(jì)算機(jī)化,網(wǎng)絡(luò)化,智能化,保護(hù)、控制、測(cè)量和數(shù)據(jù)通信一體化發(fā)展。主變?nèi)萘繛?300kVA,電壓等級(jí)為35/10kV。2)運(yùn)行的靈活性:主接線系統(tǒng)應(yīng)能靈活地適應(yīng)各種工作情況,特別是當(dāng)一部分設(shè)備檢修或工作情況發(fā)生變化時(shí),能夠通過(guò)倒換開關(guān)的運(yùn)行方式,做到調(diào)度靈活,不中斷向用戶的供電。對(duì)于電源進(jìn)線電壓為35kV及以上的變電站,通常是經(jīng)變電站總降壓變電所降為10kV的高壓配電電壓,然后經(jīng)下一級(jí)變電所,降為一般低壓設(shè)備所需的電壓。這種內(nèi)橋式結(jié)線多用于電源線路較長(zhǎng)因而發(fā)生故障和停電檢修的機(jī)會(huì)較多、并且變電所的變壓器不需要經(jīng)常切換的總降壓變電所。適用于機(jī)修類用電設(shè)備的計(jì)算,其他各類車間和車間變電所設(shè)計(jì)亦常采用。進(jìn)行短路電流計(jì)算,首先要繪制計(jì)算電路圖。其中電流速斷保護(hù)為主保護(hù),不帶時(shí)限,0s跳閘。本設(shè)計(jì)采用較經(jīng)濟(jì)的BCH2
點(diǎn)擊復(fù)制文檔內(nèi)容
公司管理相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1