【正文】
t require operators to pletely retool and won39。2.研制硬件,設(shè)計(jì)前置電路和數(shù)據(jù)采集電路。測得,陷波深度為22dB。它們都是為了保證在使用心電放大器的過程中人的安全而設(shè)計(jì)的防止觸電的部分。而,。放在體表的電極所測出的ECG信號將隨不同位置而異。帶輸入緩沖實(shí)用AD620芯片的具體電路如下:參數(shù)選擇:實(shí)際電路中去掉由22KΩ的電阻和220pF的獨(dú)石電容組成無源低通濾波器,在NN2之前分別串聯(lián)一個(gè)10KΩ的電阻,其作用是限流,然后選擇了跟隨器來穩(wěn)定電壓。 (2)、 阻容耦合電路放在由并聯(lián)型差動(dòng)放大器構(gòu)成的前級放大器和由儀器放大器構(gòu)成的后級放大器之間,這樣可為后級儀器放大器提高增益,進(jìn)而提高電路的共模抑制比提供了條件。電路對共模輸入信號沒有放大作用,共模電壓增益接近于零。④標(biāo)準(zhǔn)統(tǒng)一化:建立國際上統(tǒng)一的心電信息資料傳輸標(biāo)準(zhǔn),使得不同類型得心電檢測設(shè)備采集的心電圖信息能夠相互傳輸和交流。目前,心電圖的自動(dòng)診斷技術(shù)仍處于發(fā)展階段,由于ECG信號的變異性較大,實(shí)現(xiàn)高準(zhǔn)確率的自動(dòng)診斷以取代人工診斷仍然是人們最求的目標(biāo),當(dāng)今自動(dòng)診斷的最高水平大致在準(zhǔn)確率70%左右。如透析治療過程中,血液中各種成分在短期內(nèi)發(fā)生很大變化,從而導(dǎo)致人體內(nèi)環(huán)境發(fā)生很大變化,這些變化對心臟有著直接的刺激作用,造成心電發(fā)生改變。測量結(jié)果:測得輸入阻抗大于200MΩ。 (4)了解洋地黃中毒、電解質(zhì)紊亂等情況。重慶郵電大學(xué)本科畢業(yè)設(shè)計(jì)(論文)心電放大器的設(shè)計(jì)畢業(yè)論文目 錄前 言 1第一章 心電放大器系統(tǒng)概述 2第一節(jié) 心電放大器系統(tǒng)簡介和基本原理 2一、心電放大器總體簡介 2二、心電放大器的基本參數(shù) 3三、心電放大器的組成部分 3第二節(jié) 心電圖監(jiān)測的歷史與未來趨勢 4一、心電監(jiān)測的歷史 4二、心電信號檢測技術(shù)的發(fā)展與展望 6第三節(jié) 本章小結(jié) 6第二章 心電放大器方案論證及電路 7第一節(jié) 前置放大電路的設(shè)計(jì) 7一 、備選方案 7二、最終方案 12第二節(jié) 共模信號抑制電路的設(shè)計(jì) 12一 、備選方案 12二 、最終方案 13第三節(jié) 心電放大器其他部分的設(shè)計(jì) 14一 、低通濾波電路及時(shí)間常數(shù)電路 15二 、工頻50Hz的陷波電路 15三 、主級放大輸出電路 17四、 高通濾波電路 18五、 電源設(shè)計(jì) 19第四節(jié) 本章小結(jié) 20第三章 心電放大器相關(guān)數(shù)據(jù)測試 21第一節(jié) 心電放大器主要參數(shù)測試 21一、前置放大電路 21二、二階濾波電路 21三、 雙T50HZ陷波電路 22四、后級主運(yùn)放電路 22第二節(jié) 本章小結(jié) 22結(jié) 論 23致 謝 24參考文獻(xiàn) 25附 錄 …………………………………………………………………………………………27 一、英文原文…………………………………………………………………………………27 二、英文翻譯…………………………………………………………………………………35 三、工程設(shè)計(jì)圖紙……………………………………………………………………………43 45 前 言心臟是循環(huán)系統(tǒng)中重要的器官。(5)心電監(jiān)護(hù)已廣泛應(yīng)用于手術(shù)、麻醉、用藥觀察、航天、體育等的心電監(jiān)測以及危重病人的搶救。2 輸入噪聲測量方法:接好電路,將兩輸入端接,測量其輸出信號幅度的大小。因此,檢測心電信號,及時(shí)的為醫(yī)生提供信息,準(zhǔn)確地反映心臟方面的變化,可有效地提高血液凈化治療中的安全性。在心電圖技術(shù)不斷發(fā)展的同時(shí),針對心電圖不能長時(shí)間連續(xù)看記錄的缺陷,1957年,美國物理學(xué)家Holter首創(chuàng)了一種用磁帶記錄器對正?;顒?dòng)狀態(tài)下的病人做長時(shí)間連續(xù)心電圖記錄的方法,開辟了時(shí)間全信息和環(huán)境全信息心電記錄和診斷的新領(lǐng)域,從而在某種程度上彌補(bǔ)了常規(guī)心電圖的不足之處。第三節(jié) 本章小結(jié)本章節(jié)主要介紹了心電放大儀器的設(shè)計(jì)思路,并著重介紹了本論文討論的心電放大器部分的內(nèi)容,基本上都是理論的簡單了解。這不僅與實(shí)際的共模輸入有關(guān),而且也與A3和A4的失調(diào)電壓和漂移有關(guān)。同時(shí),由于前置放大器的輸出阻抗很低,同時(shí)又采用共模驅(qū)動(dòng)技術(shù),避免了阻容耦合電路中的阻、容元件參數(shù)不對稱(匹配)導(dǎo)致的共模干擾轉(zhuǎn)換成差模干擾的情況發(fā)生。 或運(yùn)放采用四運(yùn)放TL084。心周期中某段ECG描跡在這一電極位置不明顯,而在另一位置上卻很清楚。 DC/DC:直流/直流轉(zhuǎn)換電路主要的目的是進(jìn)行電壓的變換及隔離因?yàn)橹绷鞑荒苤苯油ㄟ^變壓器升、降壓,所以先將直流通過開關(guān)電路變成交流,頻率一般是幾百K,這時(shí)的交流波形沒有交流電正弦波那樣好。陷波帶寬測量方法:不斷調(diào)節(jié)信號發(fā)生器信號的頻率。在前置電路中,集成放大器AD620作為輸入級,該芯片極低的失調(diào)電壓及漂移和高共模抑制比保證了心電信號完好的被捕捉;隔離電路的設(shè)計(jì)可保證被測試病人的安全;通過兩級放大,成功的將信號放大1000倍,使信號由毫伏級放大到伏級,同時(shí)把信號頻率限制在0.05Hz~100Hz的通帶上,而且設(shè)計(jì)了陷波器抑制50Hz工頻干擾。t require carriers to purchase costly extra an open system IP wireless environment would probably further reduces costs for service providers by ushering in an era of real equipment interoperability.H. ScalabilityScalability, or the ability to handle increasing numbers of users and diversity of services, is more challenging with mobile networks.Design for Scalability, includes information that can help you meet changing usage demands .Because an all IP core layer of 4G is easily scalable, it is ideally suited to meet this challenge. AND COMPARISON OF BROADBAND WIRELESS1) First Generation (1G): 1G wireless mobile munication systems, was introduced in the early wireless was analog and supported the first generation of analog cell phones. They include a signaling protocol known as SS7 (Signaling System 7).2) Second Generation (2G): 2G systems, fielded in the late 1980s, were intended primarily for voice transmission and was all about digital PCS.3) Third Generation (3G): 3G in wireless will be a deliberate migration to faster, datacentric wireless networks. The immediate goal is to raise transmission speeds from 125kbps to 2M bit/sec.4) Fourth Generation (4G): In reality, as of first half of 2002, 4G is a conceptual framework for or a discussion point to address future needs of a universal high speed wireless network that will interface with wire line backbone network seamlessly.IV. THE 4G NETWORK THAT THE CELLHEADS DREAM ABOUT4G can be imagined of as an integrated wireless system that enables seamless roaming between user can be operating in cellular technology network and get handed over to a satellitebased network and back to a fixed wireless network, depending upon the network coverage and preference of charging.A. The GoalsOpen Mobile Alliance’s (OMA) main goal is to make sure different wireless services and devices work together, and across countries, operators, and mobile plans in the group39。 it is a ing together of services and need all network that utilizes IP in its fullest form with converged voice and data capability,which the 4G will achieve.G. Cost4G systems will prove far cheaper than 3G, since they can be built atop existing networks and won39。本課題針對心電信號的這些特性,以簡便實(shí)用可靠為原則展開研究,完成了以下工作:1.分析心電信號的特性、噪聲來源、導(dǎo)聯(lián)方法,提出設(shè)計(jì)要求及總體設(shè)計(jì)方案。50HZ處的陷波深度測量方法:,分別測量輸入信號和輸出信號的幅度。 電源實(shí)際電路圖 其他部分的討論雖然本論文只討論心電放大器部分,但是仍然需要簡述一下另兩個(gè)在實(shí)際心電放大器的重要組成部分。,引入負(fù)反饋改善選頻作用。心臟電興奮傳導(dǎo)系統(tǒng)所產(chǎn)生的電壓是幅值及空間方向隨時(shí)間變化的向量。二、最終方案 綜合考慮,AD620是一個(gè)最適合的放大器,它只要用一個(gè)外部電阻就可以進(jìn)行1—1000的放大倍數(shù),精度也較高,而且是DIP封裝便于使用,所以在選擇放大電路的時(shí)候運(yùn)用AD620芯片。 另外,在理論上并聯(lián)型差動(dòng)放大器的共模抑制比與電路的外圍電阻的精度和阻值無關(guān)。電路優(yōu)點(diǎn):差模信號按差模增益放大,遠(yuǎn)高于共模成分(噪聲);決定增益的電阻(RRp、R3)理論上對共模抑制比沒有影響,因此電阻的誤差不重要。心電檢測設(shè)備與互聯(lián)網(wǎng)相連以實(shí)現(xiàn)心電信號的現(xiàn)場采集,即時(shí)傳輸和遠(yuǎn)程診斷將是未來發(fā)展的一個(gè)重要方向。目前,算法有多種,具有代表性的算法有:數(shù)字濾波算法、小波算法、神經(jīng)網(wǎng)絡(luò)算法、模糊控制算法、形態(tài)學(xué)算法等,早期的自動(dòng)診斷算法采用某一種算法,現(xiàn)代自動(dòng)診斷算法將多種算法加以融合取長補(bǔ)短,以實(shí)現(xiàn)高準(zhǔn)確率的自動(dòng)診斷。危重患者易發(fā)生各種心律失常和不同程度心肌缺血,特別是惡性心律失常和無癥狀心肌缺血。1 輸入阻抗測量方法:接好電源,將輸出接地,用萬用表測量兩輸入端之間的阻抗,即輸入阻抗。 (3)指示左右房竄肥大的情況,協(xié)助判別心瓣膜病、高血壓病、肺源性及先天性心臟病的診斷。由于心臟不斷地進(jìn)行有節(jié)奏的收縮和舒張活動(dòng),血液才能在閉鎖的循環(huán)系統(tǒng)中不停地流動(dòng)。 臨床上,ECG是醫(yī)生診斷心臟疾病的主要依據(jù)之一。測量結(jié)果:系統(tǒng)性能最好的時(shí)候,反算到輸入端,可得輸入噪聲為45uV。1887年,法國著名的電生理學(xué)家AD Waller應(yīng)用Lippman毛細(xì)管靜電計(jì)描記出人類史上第一份心電圖,開創(chuàng)了心電圖記錄的先河。這種長時(shí)間連續(xù)記錄的心電圖稱為動(dòng)態(tài)心電圖(Ambulator,Electrocardiogram,AEGC),它提供的長時(shí)間動(dòng)態(tài)心電圖記錄對心率失常的檢出、早期心血管病診斷、抗心律失常治療的評價(jià)以及心律失常和生理關(guān)系的研究具有重要意義,它是常規(guī)心電圖的重要補(bǔ)充與發(fā)展。不過從總體上來說,本論文研究的問題也更偏重于實(shí)際運(yùn)用,所以本章顯得略微簡潔明了,只求為后續(xù)章節(jié)提供理論的依據(jù)。如果A3和A4有相等的漂移速率,且向同一方向漂移,那么漂移就作為共模信號出現(xiàn),沒有被放大,還能被第二級抑制。 (3)、后級電路采用儀器放大器,將雙端信號轉(zhuǎn)換為單端信號輸出。RR電阻網(wǎng)絡(luò)中的電阻取10KΩ,選取的時(shí)候通過測量選取阻值基本一樣的電阻。為了完整描述心臟的活動(dòng)狀況,應(yīng)采用多電極導(dǎo)聯(lián)方式測量心電信號,基于現(xiàn)在的實(shí)驗(yàn)條件及要求,選擇3導(dǎo)聯(lián)方式:左臂(LA),右臂(RA)以及右腿(RL)。 50HZ雙T陷波電路理論圖參數(shù)選擇:參數(shù)通過計(jì)算得到。變成交流后通過變壓器進(jìn)行變壓,輸出的交流通過整流、濾波、穩(wěn)壓等電路變回直流。測得,帶寬為177。致 謝畢業(yè)設(shè)計(jì)完成了,在這個(gè)過程中我學(xué)到了很多東西。s charter include:? Deliver open standards and specifications based on market and customer requirements.?