大型綜合樓給水排水消防系統(tǒng)設(shè)計(jì)_畢業(yè)設(shè)計(jì)說(shuō)明書(shū)(更新版)

  

【正文】 水頭損失的 25%計(jì),沿程水頭損失為 ,則有H2=*=; 由第二節(jié)水池、水表的計(jì)算可知,水流經(jīng)過(guò)水表 的水頭損失為 H3=; 低區(qū)最不利配水點(diǎn)為離 JLD1 最遠(yuǎn)的洗臉盆,所需流出水頭按 H4=50kPa; 則低區(qū)給水系統(tǒng)所需的水壓為 H=269+++50=; 市政管網(wǎng)供水壓力為 350kPa室內(nèi)所需供水壓力 ,故可以滿足 2~ 6層的供水要求。/h ,H=~~ ,N=)兩用一備。高區(qū)環(huán)狀管網(wǎng)的橫干管分別布內(nèi)蒙古工業(yè)大學(xué)本科畢業(yè)論文 27 置在 24 層、 22 層和 4 層的吊頂中,低區(qū)環(huán)狀管網(wǎng)的橫干管分別布置在 4 層和地下1 層的吊頂中。 22 bRS ?? (21) 式中 S消火栓間距, m; R消火栓保護(hù)半徑, m, R=L1+L2; L1水龍帶敷設(shè)長(zhǎng)度, m,可取配備水龍帶長(zhǎng)度的 90%; L2水槍充實(shí)水柱在平面上的投影長(zhǎng)度, m,水槍射流上傾角按 45o計(jì); b消火栓最大保護(hù)寬度, m。 . 消防水箱設(shè)計(jì)計(jì)算 . 設(shè)計(jì)計(jì)算依據(jù) 水箱消 防貯水量應(yīng)按建筑物的室內(nèi)消防用水總量的 10 分鐘用水量進(jìn)行計(jì)算。 市政給水管網(wǎng)管徑為 300mm,水壓為 ,室外環(huán)狀給水管網(wǎng)與市政給水管網(wǎng)之間通過(guò)兩根連接管連接,連接管的管徑為 250mm。 查表得 ? =, f? =,則Ⅰ號(hào)消防立管 24 層消火栓的水槍造成 13m充實(shí)水柱所需的壓力為: k P aOmHHq 2 ????? ?? . 水槍噴嘴射流量 水槍噴嘴射流量按下式計(jì)算: qxh BHq ? (26) 式中 xhq 水槍的射流量, L/s; B水槍水流特性系數(shù),建《建筑給水排水工程》 (第五版 )表 ; Hq水槍噴嘴處壓力, kPa。 由前面計(jì)算知,立管Ⅰ上 24 層消火栓口的壓力為 H24=,消防流量為 q24=。 表 31 水泵供水工況計(jì)算表 管段 流量 (L/s) 管徑 (mm) 流速(m/s) 單阻(mH2O/m) 管長(zhǎng) (m) 水頭損失(mH2O) 2726 125 2625 += 125 25A += 125 AB 125 BC 200 CD 200 DE 200 ∑ h = . 水箱供。 23 層消火栓的消防出水量為 BqqLAH xxd2223 ???? sLBALHqdx ?????? 22 層消火栓處的壓力為 H22+(層高 )+(22~23 層消防立管的水頭損失 ),即H22=++ ==。, sLBHq qxh ???? . 水帶水頭損失 水帶水頭損失按下式計(jì)算: 2xhdZd qLAh ??? (27) 式中 hd水帶水頭損失, mH2O; Ld水帶長(zhǎng)度, m; Az水帶阻力系數(shù),建《建筑給水排水工程》 (第五版 )表 。 則取長(zhǎng) ?寬 ?高 =? 9? = . 最不利點(diǎn)消火栓所需壓力和實(shí)際射流量 本綜合樓選用 65mm 口徑的消火栓,水槍噴嘴口徑為 19mm,直徑為 65mm,長(zhǎng)度為 25m的襯膠水龍帶。 為避免水箱容積過(guò)大,《高規(guī)》第 規(guī)定,消防水箱的最小貯水量應(yīng)符合下列要求: 一類(lèi)公共建筑不應(yīng)小于 18m3;二類(lèi)公共建筑和一類(lèi)居住建筑不應(yīng)小于12m3;二類(lèi)居 住建筑不應(yīng)小于 。 水槍充實(shí)水柱長(zhǎng)度應(yīng)根據(jù)建筑物的層高和選定水槍的設(shè)計(jì)流量通過(guò)水力計(jì)算確定。消防泵的壓水管設(shè)兩條管路與消防環(huán)狀管網(wǎng)連接,其管徑的設(shè)計(jì)考慮到當(dāng)其中一根發(fā)生故障時(shí),另一根管路應(yīng)能保證消防用水量和水壓的要求。/h ,H=127~125~121m ,N=30kw) 一組。水力計(jì)算表如表 1表 1表 19 所示。對(duì)本綜合樓采用變頻調(diào)速并聯(lián)給水方案來(lái)講,低區(qū)給水系統(tǒng)需要復(fù)合室外管網(wǎng)提供的水壓是否滿足低區(qū)給水系統(tǒng)所需壓力;中、高區(qū)給水系統(tǒng)需要確定水泵的流量和揚(yáng)程,為選擇水泵提供依據(jù)。 . 水表的選擇 ( 1)設(shè)計(jì)計(jì)算依據(jù) 水表的選擇包括確定水表的類(lèi)型及口徑,水表的類(lèi)型應(yīng)根據(jù)水表的特性和通過(guò)水表的水質(zhì)、水量、水溫、水壓等情況選定。 . 引入管設(shè)計(jì)流量的確定 ( 1)設(shè)計(jì)計(jì)算依據(jù) 摘自《建筑給水排水設(shè)計(jì)規(guī)范》 (GB5001520xx) 建筑物的給水引入管的設(shè)計(jì)流量,符合下列要求: 1 當(dāng)建筑物內(nèi)的生活用水全部由室外管網(wǎng)直接供水時(shí),取建筑物內(nèi)的生活用水設(shè)計(jì)秒流量。根據(jù)圖紙資料,經(jīng)計(jì)算,確定這些場(chǎng)所的人口數(shù)約為 3382 人; 內(nèi)蒙古工業(yè)大學(xué)本科畢業(yè)論文 7 ( 2) 商場(chǎng)面積約為 1300 m2; 表 11 用水量計(jì)算表 序號(hào) 名稱(chēng) 用水單位數(shù) 用水定額 最大日用水量 Qd(L/d) Kh 最大時(shí)用水量 Qh(L/h) 用水時(shí)間 T(h) 1 辦公室 3382 人 /班 40L/(人 .班 ) 135280 18939 10 2 商場(chǎng) 1300m2 6L/m2 7800 910 12 合計(jì) 143080 19849 mQd ?? hmQ / 3h ? . 水池、水表的計(jì)算 . 水池的計(jì)算 高層建筑的生活給水系統(tǒng),應(yīng)能充分、安全、可靠地保證生活用水 。 通過(guò)設(shè)計(jì)應(yīng)熟悉和了解建筑給排水工程的一般設(shè)計(jì)原則、步驟與方法,了解建筑給水排水方案比較的原則和方法,掌握冷水、熱水、消防給水、排水計(jì)算方法以及設(shè)計(jì)說(shuō)明書(shū)的編寫(xiě)和施工圖設(shè)計(jì)與繪制的方法。 內(nèi)蒙古工業(yè)大學(xué)本科畢業(yè)論文 2 Abstract This building is the largescale prehensive building, is located in the centre of Hohhot , the construction is highly , total floor space approximately 35,000 square meters. This building possesses for water draining water presses the highrise construction to request for draining water to carry on the design. Unifies the actual situation, according to the building nature, the use, is equipped with the consummation with the room in for the water draining water sanitary equipment, concrete gives the drainage system design to be as follows: Water supply system: This construction underground to ground six by outdoor municipal administration pipe work direct water supply, the water supply system of seven to twentyfour is the water pump、 the roof water tank and the reducing value joins. supposed two leadin tubes. From different direction introduction. Both has safeguarded the water supply security, and saved the energy consumption. Drainage system: This design uses the dirt waste water parting emissions system. The tubing used had the shock resistance cast iron pipe waste. might further improve the environment quality for this. In the basement nearby the fire electricity stairwell, the pump house ground are equipped with the sump and the waste water lifting gear. Fire prevention system: This building fire protection rank belongs to the dangerous levelⅡ The level, the design content including the fire hydrant system and sprays automatically system. In supposes the experimental fire hydrant installment in the roof water tank between, the fire hydrant service pipe assumes the ringlike arrangement。 排水系統(tǒng): 本設(shè)計(jì)采用污廢水分流排放體 制。既保障了供水安全,又節(jié)約了能耗。 關(guān)鍵詞: 給水;排水;消火栓;自動(dòng)噴淋。本課題的主要目的訓(xùn)練自己綜合應(yīng)用所學(xué)基礎(chǔ)課、技術(shù)基礎(chǔ)課和專(zhuān)業(yè)課知識(shí),在教師指導(dǎo)下培養(yǎng)自己獨(dú)立完成高層建筑給水、排水、消防給水及熱水供應(yīng)等設(shè)計(jì)的能力,使自己受到工程師的基本訓(xùn)練。用水人數(shù) (用水單位數(shù) )計(jì)算如下: ( 1) 每間管理用房、值班室、變電所、保安房和廣播室均按兩個(gè)人口計(jì)算;辦公室辦公人數(shù)按有效面積內(nèi) 5m2/人計(jì)算。 ( 2)水池的計(jì)算 為保證生活用水水質(zhì),本綜 合樓的生活貯水池獨(dú)立設(shè)置,由于資料不足,且低區(qū)由市政供水,故生活貯水池的容積取中、高區(qū)日用水量的 25%,則生活貯水池的有效容積為: ? ? 31 3 7 . 5 95 5 0 . 3 7% . 1 53 . 2 2%25 mV y ???????? 將生活貯水池設(shè)置在地下二層的設(shè)備間內(nèi),采用不銹鋼材料,幾何尺寸為:? ? ? ? ? ?高寬長(zhǎng) mmm ?? ,有效容積為: 3138. . 07. 0 m??? ,總?cè)莘e為:. 07. 0 m??? 。 內(nèi)蒙古工業(yè)大學(xué)本科畢業(yè)論文 9 本綜合樓的最大時(shí)生活流量 =,室內(nèi)、外消防用水量=40+30+22=92L/s,則室外生活消防共用管道通過(guò)的流量為 +92=。 . 給水管網(wǎng)水力計(jì)算 給水管網(wǎng)水力計(jì)算的目的在于確定管段的管徑和給水系統(tǒng)所需壓力。 . 中區(qū)給水管網(wǎng)水力計(jì)算 中區(qū) 7~ 16 層計(jì)算用圖如圖 1圖 16 所示。 高區(qū)水泵的確定( 16~24 層) Qbg=Qgg=Hbg=100+++5= 選 ISB65/4025125 型號(hào)變頻泵( Q=~~179。 消防水箱出來(lái)兩條出水管,分別與 27 層橫干管和 16 層橫干管相連接。 消火栓保護(hù)半徑按下式計(jì)算: hLCR d ??? (22) 式中 R消火栓保護(hù)半徑 , m; C水帶展開(kāi)時(shí)的彎曲折減系數(shù),一般取 ~; h水槍充實(shí)水柱傾斜 45o 時(shí)的水平投影, m; h=,對(duì)一般建筑(層高為 3~ 由于兩樓板間的限制,一般取 h=; Hm水槍充實(shí)水柱長(zhǎng)度, m。消防水箱容積按下式計(jì)算: 100 0 60??? xxx TqV (23) 式中 Vx消防水箱容積, m3; qx室內(nèi)消防用水總量, L/s; Tx火災(zāi)初期時(shí)間,按 10min 計(jì)。室外消火栓用水量全部有室外管網(wǎng)提供,水池進(jìn)水管管徑為 DN80,則補(bǔ)水量為: 32 6 0 mV ?????? ? 室內(nèi)所需的消防用水量為: 35 1 1 . 21 0 0 03 6 0 01221 0 0 03 6 0 0340 mV c ??????? 則消防水池的有效容積為: 36 .945 mVVV cf ??? ,取 460m3。 查表得, B=,槍口壓力 Hq=,則水槍射流量為: 滿足要求。 23 層消火栓處的壓力為 H24+(層高 )+(23~24 層消防立管的水頭損失 ),即H23=++ =
點(diǎn)擊復(fù)制文檔內(nèi)容
研究報(bào)告相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1