freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

廣東某機(jī)房樓臨時用電施工方案(更新版)

2025-09-14 00:47上一頁面

下一頁面
  

【正文】 90 = 27 kWQjs = Pjs tgφ=27 = kvar(12)、螺旋鉆孔機(jī)Kx = Cosφ = tgφ = Pjs = 90 = 27 kWQjs = Pjs tgφ=27 = kvar(13)、自落式混凝土攪拌機(jī)Kx = Cosφ = tgφ = Pjs = 15 = kWQjs = Pjs tgφ= = kvar(14)、插入式振動器Kx = Cosφ = tgφ = Pjs = = kWQjs = Pjs tgφ= = kvar(15)、平板式振動器Kx = Cosφ = tgφ = Pjs = = kWQjs = Pjs tgφ= = kvar(16)、鋼筋調(diào)直機(jī)Kx = Cosφ = tgφ = Pjs = = kWQjs = Pjs tgφ= = kvar(17)、鋼筋切斷機(jī)Kx = Cosφ = tgφ = Pjs = 3 = kWQjs = Pjs tgφ= = kvar(18)、鋼筋彎曲機(jī)Kx = Cosφ = tgφ = Pjs = 3 = kWQjs = Pjs tgφ= = kvar(19)、木工圓鋸Kx = Cosφ = tgφ = Pjs = = kWQjs = Pjs tgφ= = kvar(20)、泥漿泵Kx = Cosφ = tgφ = Pjs = 30 = kWQjs = Pjs tgφ= = kvar(21)、卷揚機(jī)Kx = Cosφ = tgφ = Pjs = 3 = kWQjs = Pjs tgφ= = kvar(22)、卷揚機(jī)Kx = Cosφ = tgφ = Pjs = 3 = kWQjs = Pjs tgφ= = kvar(23)、熒光燈Kx = Cosφ = tgφ = Pjs = = kWQjs = Pjs tgφ= = kvar(24)、熒光燈Kx = Cosφ = tgφ = Pjs = = kWQjs = Pjs tgφ= = kvar(25)、熒光燈Kx = Cosφ = tgφ = Pjs = = kWQjs = Pjs tgφ= = kvar(26)、熒光燈Kx = Cosφ = tgφ = Pjs = = kWQjs = Pjs tgφ= = kvar(27)、熒光燈Kx = Cosφ = tgφ = Pjs = = kWQjs = Pjs tgφ= = kvar(28)總的計算負(fù)荷計算,總箱同期系數(shù)取 Kx = 總的有功功率Pjs = Kx∑Pjs = (++++++++++27+27+++++++++++++++) = kW總的無功功率Qjs = Kx∑Qjs =(++++++++++++++++++++++++++) = kvar總的視在功率Sjs = ( Pjs2+Qjs2 )1/2 = (+)1/2 = kVA總的計算電流計算Ijs = Sjs/(Ue) = () = A1號干線線路上導(dǎo)線截面及分配箱、開關(guān)箱內(nèi)電氣設(shè)備選擇:在選擇前應(yīng)對照平面圖和系統(tǒng)圖先由用電設(shè)備至開關(guān)箱計算,再由開關(guān)箱至分配箱計算,選擇導(dǎo)線及開關(guān)設(shè)備。工程說明:本工程建設(shè)用地位于建筑總平圖中所示,本次開發(fā)建設(shè)的*****中心(一期)機(jī)房樓工程位于D區(qū)地塊。一、編制依據(jù)《低壓配電設(shè)計規(guī)范》GB5005495中國建筑工業(yè)出版社《建筑工程施工現(xiàn)場供電安全規(guī)范》GB5019493中國建筑工業(yè)出版社《通用用電設(shè)備配電設(shè)計規(guī)范》GB5005593中國建筑工業(yè)出版社《供配電系統(tǒng)設(shè)計規(guī)范》GB5005295中國建筑工業(yè)出版社《施工現(xiàn)場臨時用電安全技術(shù)規(guī)范》JGJ462005中國建筑工業(yè)出版社《建筑施工安全檢查標(biāo)準(zhǔn)》JGJ5999二、施工條件施工現(xiàn)場用電量統(tǒng)計表:序號 機(jī)具名稱 型號 安裝功率(kW) 數(shù)量 合計功率(kW)1 熒光燈 1 2 熒光燈 1 3 熒光燈 1 4 熒光燈 1 5 熒光燈 1 6 碘鎢燈 1 1 1 7 碘鎢燈 1 1 1 8 高壓鈉燈 1 1 1 9 塔式起重機(jī) TQ60/80 1 10 蛙式夯土機(jī) HW32 1 11 螺旋鉆孔機(jī) ZKL800 90 1 90 12 螺旋鉆孔機(jī) ZKL800 90 1 90 13 JD350 15 1 15 14 插入式振動器 ZX35 1 15 平板式振動器 ZB5 1 16 鋼筋調(diào)直機(jī) GT6/8 1 17 鋼筋切斷機(jī) QJ321 3 1 3 18 鋼筋彎曲機(jī) GW40 3 1 3 19 木工圓鋸 MJ106 1 20 泥漿泵 紅星30 30 1 30 21 卷揚機(jī) 3 1 3 22 卷揚機(jī) 3 1 3 23 熒光燈 1 24 熒光燈 1 25 熒光燈 1 26 熒光燈 1 27 熒光燈 1 三、設(shè)計內(nèi)容和步驟現(xiàn)場勘探及初步設(shè)計:(1)本工程所在施工現(xiàn)場范圍內(nèi)施工前無各種埋地管線。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)隔離開關(guān)為DZ520/3 ,其脫扣器整定電流值為Ir = 16A,漏電保護(hù)器為 DZ15L100/30。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)隔離開關(guān)為DZ520/3 ,其脫扣器整定電流值為Ir = 16A,漏電保護(hù)器為 DZ15L100/30。iii)選擇電氣設(shè)備選擇分配箱內(nèi)開關(guān)為DZ520/3 ,其脫扣器整定電流值為Ir = 16A,漏電保護(hù)器為 DZ15L100/30。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)隔離開關(guān)為DZ10250/3 ,其脫扣器整定電流值為Ir = 200A,漏電保護(hù)器為 DZ10L250/3。分配箱至開關(guān)箱,開關(guān)箱至用電設(shè)備的導(dǎo)線敷設(shè)采用銅橡皮絕緣導(dǎo)線穿焊接鋼管敷設(shè)。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)隔離開關(guān)為DZ550/3 ,其脫扣器整定電流值為Ir = 40A,漏電保護(hù)器為 DZ15L100/30。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)隔離開關(guān)為Hk115/3,漏電保護(hù)器為 DZ15L100/30。iii)選擇電氣設(shè)備選擇分配箱內(nèi)開關(guān)為DZ10600/3 ,其脫扣器整定電流值為Ir = 480A,漏電保護(hù)器為 DZ10L250/3。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)隔離開關(guān)為DZ520/3 ,其脫扣器整定電流值為Ir = 16A,漏電保護(hù)器為 DZ15L100/30。ii)選擇出線開關(guān)4號干線出線開關(guān)選擇DZ520/3 ,其脫扣器整定電流值為Ir = 16A,漏電保護(hù)器為 DZ15L100/30。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)隔離開關(guān)為DZ520/3 ,其脫扣器整定電流值為Ir = 16A,漏電保護(hù)器為 DZ15L100/30。iii)選擇電氣設(shè)備選擇分配箱內(nèi)開關(guān)為DZ520/3 ,其脫扣器整定電流值為Ir = 16A,漏電保護(hù)器為 DZ15L100/30。(2)選擇總進(jìn)線開關(guān):DZ10600/3 ,其脫扣器整定電流值為Ir = 480A。它的作用是當(dāng)電氣設(shè)備的金屬外殼帶電時,如果人體觸及此外殼時,由于人體的電阻遠(yuǎn)大于接地體電阻,則大部分電流經(jīng)接地體流入大地,而流經(jīng)人體的電流很小。TNS供電系統(tǒng)。不允得對一部分設(shè)備采取保護(hù)接地,對另一部分采取保護(hù)接零。5)總配箱中漏電保護(hù)器的額定漏電動作電流應(yīng)大于30mA,但其額定漏電動作電流與額定漏電動作時間的乘積不應(yīng)大于30mA對下列特殊場所應(yīng)使用安全電壓照明器。3)總配電箱應(yīng)設(shè)置在靠近電源區(qū)域,分配電箱應(yīng)設(shè)置在用電設(shè)備或負(fù)荷相對集中的區(qū)域,分配電箱與開關(guān)箱的距離不得超過30m,開關(guān)箱與其控制的固定式用電設(shè)備的水平距離不應(yīng)超過3m。固定式配電箱、~。并且電器設(shè)備之間、設(shè)備與板四周的距離應(yīng)符合有關(guān)工藝標(biāo)準(zhǔn)的要求。7)導(dǎo)線剝削處不應(yīng)傷線芯過長,導(dǎo)線壓頭應(yīng)牢固可靠,多股導(dǎo)線不應(yīng)盤卷壓接,應(yīng)加裝壓線端子(有壓線孔者除外)。上下腳手架的斜道嚴(yán)禁搭設(shè)在有外電線路的一側(cè)。9)電氣設(shè)備現(xiàn)場周圍不得存放易燃易爆物、污源和腐蝕介質(zhì),否則應(yīng)予清除或做防護(hù)處置,其防護(hù)等級必須與環(huán)境條件相適應(yīng)。3)配電箱、開關(guān)箱應(yīng)每月進(jìn)行一次檢查和維修。8)配電箱、開關(guān)箱內(nèi)不得隨意掛接其他用電設(shè)備。線路末端電壓偏移不大于5%。表1 表2 表3 9)架空線路與鄰近線路或固定物的距離應(yīng)符合表4的規(guī)定。的轉(zhuǎn)角桿應(yīng)采用雙橫擔(dān)雙絕緣子;45176。15)因受地形環(huán)境限制不能設(shè)拉線時,可采用撐桿代替拉線,其底部應(yīng)墊底盤或石塊。18)架空線路必須有過載保護(hù)。3)電纜類型應(yīng)更具敷設(shè)方式、環(huán)境條件等選擇。9)在建工程內(nèi)的電纜線路必須采用電纜埋地引入,嚴(yán)禁穿越腳手架引入。5)室內(nèi)配線所用導(dǎo)線或電纜的截面應(yīng)更具用電設(shè)備或線路的計算負(fù)荷確定。(5)、建立工程拆除制度建筑工程竣工后,臨時用電工程的拆除應(yīng)有統(tǒng)一的組織和指揮,并須規(guī)定拆除時間、人員、程序、方法、注意事項和防護(hù)措施等。電流流過電阻時,會消耗電能產(chǎn)生熱量,導(dǎo)致過熱引起火災(zāi)。經(jīng)常教育用電人員正確執(zhí)行安全操作規(guī)程,避免作業(yè)不當(dāng)造成火災(zāi)。使用碘鎢燈時,燈與易燃物間距要大于30cm,室內(nèi)不準(zhǔn)使用功率超過100W的燈泡,嚴(yán)禁使用床頭燈。(11)、施工現(xiàn)場應(yīng)建立防火檢查制度,強化電氣防火領(lǐng)導(dǎo)體制,建立電氣防
點擊復(fù)制文檔內(nèi)容
試題試卷相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1