freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

變電所畢業(yè)設(shè)計(jì)-龍灣二次6010kv降壓變電所繼電保護(hù)部分初步設(shè)計(jì)(完整版)

  

【正文】 any factors that meticulous consideration engineering design, end plete this . . design project. Pass to plete this graduate design the thesis, further appreciating the our country the policy idea of electric power industry developments with the economic standpoint, educates to proceed to the engineering technique, economy more pletely to synthesize the analytical skill. Key words substation ,short circuit puting ,relaying ,Protect an allocation . . 目 錄 摘 要 ........................................................................................................................................... I ABSTRACT ....................................................................................................................................II 引 言 .......................................................................................................................................... 1 第一篇 說明書 ............................................................................................................................ 2 第一章 主變壓器的選擇 ............................................................................................................ 2 第二章 電氣主接線的選擇 ........................................................................................................ 5 主接線的設(shè)計(jì)原則及基本要求 .......................................... 5 本變電所主接線的選擇 ................................................ 6 第三章 短路電流的計(jì)算說明 .................................................................................................... 9 短路電流計(jì)算的目的 .................................................. 9 短路的基本類型 ...................................................... 9 短路電流計(jì)算的基本假定 .............................................. 9 一般規(guī)定 ............................................................ 9 計(jì)算步驟 ........................................................... 10 計(jì)算方法 ........................................................... 10 第四章 變電所繼電保護(hù)配置 .................................................................................................. 11 變壓器保護(hù)原則 ..................................................... 11 保護(hù)配置說明 ....................................................... 12 各種繼電保護(hù)原理 ................................................... 16 第二篇 計(jì)算書 .......................................................................................................................... 28 第一章 主變壓器的選擇計(jì)算部分 .......................................................................................... 28 第二章 短路電流的計(jì)算 .......................................................................................................... 30 各元件電抗計(jì)算公式 ................................................. 30 系統(tǒng)計(jì)算電路圖和等值電路圖 ......................................... 30 第三章 變壓器繼電保護(hù)整定計(jì)算 .......................................................................................... 38 變壓器繼電保護(hù)整定 ................................................. 38 變壓器瓦斯保護(hù)整定 ................................................. 38 . . 變壓器差動(dòng)保護(hù)整定 ................................................. 38 過電流保護(hù)的整定計(jì)算 ............................................... 42 過負(fù)荷保護(hù)的整定計(jì)算 ............................................... 43 結(jié) 論 ........................................................................................................................................ 44 參考文獻(xiàn) ................................................................................................................................... 45 致 謝 ........................................................................................................................................ 46 附 錄 ........................................................................................................................................ 47 . . 引 言 本畢業(yè)設(shè)計(jì)論文為龍灣二次 60kv 降壓變電所電氣部分設(shè)計(jì),要求所設(shè)計(jì)的變電所能長(zhǎng)期可靠為其負(fù)荷供電。 b. 對(duì)于地區(qū)性孤立的一次變電所或大型工業(yè)專用變電所,在設(shè)計(jì)時(shí)應(yīng)考慮裝設(shè)三臺(tái)主變壓器的可能性 c. 對(duì)于規(guī)劃只裝設(shè)兩臺(tái)主變壓器的變電所,其變壓器基礎(chǔ)宜按大于變壓器容量的12 級(jí)設(shè) 計(jì),以便負(fù)荷發(fā)展時(shí),更換變壓器的容量。 b. 主變壓器繞組數(shù)量的選擇: 對(duì)深入引進(jìn)至負(fù)荷中心,待設(shè)變電所具有直接從高壓降為低壓供電條件的變電所,為簡(jiǎn)化電壓等級(jí)或減少重復(fù)降壓容量,可采用雙繞組變壓器。當(dāng)其中一臺(tái)停運(yùn)檢修時(shí),考慮變壓器的過負(fù)荷能力,另一臺(tái)仍能達(dá)到全部負(fù)荷的 98%。因此,主接線設(shè)計(jì)是一個(gè)綜合性問題。 . . ( 3) 擴(kuò)建時(shí),可以容易地從初期接線過度到最終接線。但變壓器故障時(shí),則與該變壓器連接的兩臺(tái)斷路器也影響了一回未故障線路的運(yùn)行。 圖 單母線分段接線 圖 單母線分段帶旁路接線 . . 二、 兩種方案特點(diǎn)比較 規(guī)程上講,當(dāng)變電所裝有兩臺(tái)主變壓器時(shí), 610KV 側(cè)宜采用分段單母線,線路為 12回及以上時(shí)亦可采用雙母線,當(dāng)不允許停電檢修斷路器時(shí),可設(shè)置旁路設(shè)施。 max..KI :短路電流的沖擊值,即短路電流最大瞬時(shí)值。 ( 6) 元件的計(jì)算參數(shù)取其額定值,不考慮參數(shù)的誤差和調(diào)整范圍。 ② 選取基準(zhǔn)容量和基準(zhǔn)電壓。 ( 2) 繞組的匝間短路;變壓器的下列故障及異常運(yùn)行狀態(tài),應(yīng)按本節(jié)的規(guī)定裝設(shè)相應(yīng)的保護(hù)裝置??v聯(lián)差動(dòng)保護(hù)的整定值可小于額定電流。 變壓器后備保護(hù)應(yīng)能保護(hù)電流互感器與斷路器之間的故障。 上述各種保護(hù)裝置的接線宜考慮能保護(hù)電流互感器與斷路器之間的故障。因此,變壓器發(fā)生故障時(shí),必須將其從電力系統(tǒng)中切除。 對(duì)變壓器溫度升高和冷卻系統(tǒng)故障,應(yīng)按現(xiàn)行電力變壓器的標(biāo)準(zhǔn)規(guī)定,裝設(shè)信號(hào)裝置。對(duì)于高壓側(cè)電壓為 330kV及以上的變壓器,可裝設(shè)雙重差動(dòng)保護(hù)。 ( 3) 負(fù)序電流和單項(xiàng)式低電壓起動(dòng)的過電流保護(hù),可用于 63MVA 及以上升壓變壓器。 最中采用 復(fù)合電壓起動(dòng)的過電流保護(hù)。這里的低電壓繼電器和負(fù)序電壓繼電器相當(dāng)于接在一個(gè)或門上,然后在和相電流繼電器相接于與門上,相成了此邏輯關(guān)系,從而完成了對(duì)變壓器相間故障的保護(hù)。 過負(fù)荷保護(hù)應(yīng)能反映變壓器各繞組的過負(fù)荷情況。當(dāng)上述方式不符合靈敏性的要求性時(shí),則可在所有各側(cè)均裝設(shè)保護(hù)裝置。 本次變壓器保護(hù): 氣體保護(hù) (瓦斯保護(hù) ) 縱差動(dòng)保護(hù) 過電流保護(hù) 復(fù)合電壓保護(hù) 過負(fù)荷保護(hù) 保護(hù)裝置,除預(yù)先規(guī)定以外,都不允許系統(tǒng)因震蕩引起的誤動(dòng)作; 正常情況下,當(dāng)電壓互感器的二次回路或其他故障能使保護(hù)誤動(dòng)作時(shí),應(yīng)裝設(shè)線路閉鎖或其他措施。 如下圖所示: 圖 瓦斯繼電器安裝位置圖 油箱內(nèi)部發(fā)生嚴(yán)重故障時(shí),大量氣體和油流直接沖擊擋板 8,使下開口杯 l順時(shí)針方向旋轉(zhuǎn),帶動(dòng)永久磁鐵靠近下部干簧的觸點(diǎn) 3 使之閉合,發(fā)出跳閘脈沖,表示“重瓦斯”保護(hù)動(dòng)作。 ( 2) 為防止瓦斯繼電器因漏水而短路,應(yīng)在其端子和電纜引線端子箱上采取防雨措施。當(dāng)斷路器跳閘后,斷路器的輔助觸點(diǎn)斷開自保持回路,使 CKJ 恢復(fù)起始位置。它能反映變壓器繞組的相間短路、匝間短路、引 出線的相間短路以及中性點(diǎn)直接接地、系統(tǒng)側(cè)繞組和引出線上的接地短路、是大、中型電力變壓器的主要保護(hù)方式。故在實(shí)現(xiàn)變壓器差動(dòng)保護(hù)時(shí),應(yīng)先考慮對(duì)兩側(cè)電流進(jìn)行相位補(bǔ)償,再進(jìn)行數(shù)值補(bǔ)償,都能保證正常運(yùn)行和外部短路時(shí)繼電器中的電流等于零(理想)。 當(dāng)變壓器正常運(yùn)行或外部故障時(shí),注入差動(dòng)繼電器的電流為不平衡電流。故可不考慮。 有間斷角。 變壓器差動(dòng)保護(hù)的方式: 采用 BCH― 2 型差動(dòng)繼電器的差動(dòng)保護(hù) 變壓器差動(dòng)保護(hù)的整定計(jì)算 (一) 差動(dòng)繼電器動(dòng)作電流的整定計(jì)算應(yīng)考慮以下幾種情況 ( 1) 在正常運(yùn)行時(shí),防止電流互感器二次回路斷線時(shí)引起差動(dòng)保護(hù)誤動(dòng)作。 正常運(yùn)行時(shí),因?yàn)樨?fù)序電壓,所以負(fù)序電壓繼電器 KVN 不動(dòng)作,動(dòng)斷觸點(diǎn)閉合,將線電壓 Uac 加在低電壓繼電器 KVU上,其動(dòng)斷觸點(diǎn)打開,保護(hù)裝置不動(dòng)作。保護(hù)動(dòng)作后,應(yīng)帶時(shí)限動(dòng)作于跳閘。 ( 1) 變壓器后備保護(hù)應(yīng)盡可能獨(dú)立 ,而不由發(fā)電機(jī)的后備保護(hù)代替。負(fù)序電壓消失后,雖然低電壓繼電
點(diǎn)擊復(fù)制文檔內(nèi)容
公司管理相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1