【正文】
發(fā)生告警信號。 關(guān)鍵字:電力系統(tǒng)繼電保護(hù);短路計(jì)算;距離整定保護(hù);零序網(wǎng)絡(luò)ABSTRACT The design of relay protection is the calculation of 110kV power line protection mode selection and tuning. The calculation of the main phase protection on line, the selection and setting of zero sequence protection. Through the calculation of short circuit current of D1, D2, D3, D4, and then to the four of the distance protection and zero sequence current protection for the power system and its automation professional courses have a prehensive understanding of. Power system relay protection of basic knowledge, and then according to the wiring diagram and the parameters of the given 110KV line. Especially the electrical part of the electric power system relay protection, has certain research. Emphasis is the optimization of the circuit, method for shortcircuit current calculation, specific protection, distance protection in current. Through setting calculation and verification of relay protection relay protection configuration, the relay protection is correctly configured and accuracy.Keywords: power system relay protection。吉林建筑大學(xué)城建學(xué)院電氣信息工程系課程設(shè)計(jì)序號(學(xué)號): 20100090213吉林建筑大學(xué)城建學(xué)院 課 程 設(shè) 計(jì) 報(bào) 告110KV線路繼電保護(hù)課程設(shè)計(jì)姓 名孫世康系電氣信息工程系專 業(yè)電氣工程及其自動化班 級102班指導(dǎo)教師曲娜2014年1月5日目 錄摘 要 IABSTRACT Ⅱ第1章 緒論 1 繼電保護(hù)概要 1 系統(tǒng)運(yùn)行方式的確定 2 線路運(yùn)行方式選擇原則 2 變壓器中性點(diǎn)接地選擇原則 2 發(fā)電機(jī)、變壓器運(yùn)行方式選擇的原則 2 選取流過保護(hù)的最大負(fù)荷電流的原則 3 流過保護(hù)的最大、電小短路電流計(jì)算方式的選擇 3 本次課程設(shè)計(jì)的內(nèi)容及其要求 3 設(shè)計(jì)內(nèi)容 3 設(shè)計(jì)要求 4 本次課程設(shè)計(jì)的具體運(yùn)行方式選擇 4第2章 電網(wǎng)各個(gè)元件參數(shù)的計(jì)算及負(fù)荷電流的計(jì)算 6 基準(zhǔn)值選擇 6 電網(wǎng)各元件等值電抗計(jì)算 6 輸電線路等值電抗計(jì)算 7 變壓器等值電抗計(jì)算 9 最大負(fù)荷電流計(jì)算 10第3章 短路計(jì)算 11 短路電流 11 短路電流介紹和分類 11 計(jì)算目的 11 計(jì)算條件 12 短路電流計(jì)算 12 d1點(diǎn)發(fā)生短路時(shí)流過斷路器1電流 13 d2點(diǎn)發(fā)生短路時(shí)流過斷路器2電流 15 d3發(fā)生短路時(shí)流過斷路2 16 d4點(diǎn)發(fā)生短路時(shí)流過斷路器2 18第4章 繼電保護(hù)距離保護(hù)的整定計(jì)算和校驗(yàn) 20 距離保護(hù)介紹 20 斷路器1距離保護(hù)的整定計(jì)算和校驗(yàn) 21 距離保護(hù)?段的整定計(jì)算 21 距離保護(hù)Ⅱ段的整定計(jì)算和校驗(yàn) 22 距離保護(hù)Ⅲ段的整定計(jì)算和校驗(yàn) 23 24 距離保護(hù)?段的整定計(jì)算 24 距離保護(hù)Ⅱ段的整定計(jì)算和校驗(yàn) 25 距離保護(hù)Ⅲ段的整定計(jì)算和校驗(yàn) 26 斷路器3距離保護(hù)的整定計(jì)算和校驗(yàn) 27 斷路器4距離保護(hù)的整定計(jì)算和校驗(yàn) 27 距離保護(hù)?段的整定計(jì)算 27 距離保護(hù)Ⅱ段的整定計(jì)算和校驗(yàn) 28 距離保護(hù)Ⅲ段的整定計(jì)算和校驗(yàn) 29第5章 繼電保護(hù)零序電流保護(hù)的整定計(jì)算和校驗(yàn) 31 31 零序電流保護(hù)?段的整定計(jì)算 31 零序電流保護(hù)Ⅱ段的整定計(jì)算 31 零序電流保護(hù)Ш段的整定計(jì)算 32 33 零序電流保護(hù)?段的整定計(jì)算 33 零序電流保護(hù)Ⅱ段的整定計(jì)算 34 零序電流保護(hù)Ⅲ段的整定計(jì)算 34 35 36 零序電流保護(hù)?段的整定計(jì)算 36 零序電流保護(hù)Ⅱ段的整定計(jì)算 36 零序電流保護(hù)Ш段的整定計(jì)算 37 對所選擇的保護(hù)裝置進(jìn)行綜合評價(jià) 37 距離保護(hù)的綜合評價(jià) 38 對零序電流保護(hù)的評價(jià) 38總 結(jié) 39致 謝 40參考文獻(xiàn) 41摘 要 本次繼電保護(hù)設(shè)計(jì)的是110kv電網(wǎng)線路上繼電保護(hù)的方式進(jìn)行的選擇及整定計(jì)算。short circuit calculation。繼電保護(hù)的任務(wù)就是在系統(tǒng)運(yùn)行過程中發(fā)生故障(三相短路、兩相短路、單相接地等)和出現(xiàn)不正?,F(xiàn)象時(shí)(過負(fù)荷、過電壓、低電壓、低周波、瓦斯、超溫、控制與測量回路斷線等),能夠自動、迅速、有選擇性且可靠的發(fā)出跳閘命令將故障切除或發(fā)出各種相應(yīng)信號,從而減少故障和不正?,F(xiàn)象所造成的停電范圍和電氣設(shè)備的損壞程度,保證電力系統(tǒng)安全穩(wěn)定的運(yùn)行。電力系統(tǒng)繼電保護(hù)和安全自動裝置是在電力系統(tǒng)發(fā)生故障和不正常運(yùn)行情況時(shí),用于快速切除故障,消除不正常狀況的重要自動化技術(shù)和設(shè)備。 發(fā)電機(jī)、變壓器運(yùn)行方式選擇的原則(1)一個(gè)發(fā)電廠有兩臺機(jī)組時(shí),一般應(yīng)考慮全停方式,一臺檢修,另一臺故障;當(dāng)有三臺以上機(jī)組時(shí),則選擇其中兩臺容量較大機(jī)組同時(shí)停用的方式?! τ陔p電源的網(wǎng)絡(luò),一般(當(dāng)取Z1=Z2時(shí))與對側(cè)電源的運(yùn)行方式無關(guān),可按單側(cè)電源的方法選擇。%/, UK=%(4) △t=,負(fù)荷側(cè)后備保護(hù)tdz=,變壓器和母線均配置有差動保護(hù),Kzq=(5) 發(fā)電廠升壓變中性點(diǎn)直接接地,其他變壓器不接地?,F(xiàn)結(jié)合本次設(shè)計(jì)具體說明如下,系統(tǒng)的最大運(yùn)行方式是所有設(shè)備全部投入運(yùn)行;系統(tǒng)的最小運(yùn)行方式為發(fā)電機(jī)G1和G2投入,發(fā)電機(jī)G3停運(yùn)。三相系統(tǒng)中發(fā)生的短路有 4 種基本類型:三相短路,兩相短路,單相對地短路和兩相對地短路。它會產(chǎn)生很大的電動力,其大小可用來校驗(yàn)電工設(shè)備在發(fā)生短路時(shí)機(jī)械應(yīng)力的動穩(wěn)定性。⑶確定合理的主接線方案、運(yùn)行方式及限流措施。因?yàn)閱蜗喽搪坊蚨喽搪窌r(shí)的短路電流都小于三相短路電流。用電壓與電流的比值(即阻抗)構(gòu)成的繼電保護(hù),又稱阻抗保護(hù),阻抗元件的阻抗值是接入該元件的電壓與電流的比值:U/I=Z,也就是短路點(diǎn)至保護(hù)安裝處的阻抗值。當(dāng)然還可以根據(jù)非電氣量的變化來構(gòu)成某些保護(hù),如反應(yīng)變壓器油在故障時(shí)分解產(chǎn)生的氣體而構(gòu)成的氣體保護(hù)。靈敏性:是指在規(guī)定的保護(hù)范圍內(nèi),保護(hù)對故障情況的反應(yīng)能力。三段分別稱為距離保護(hù)的Ⅰ、Ⅱ、Ⅲ段,它們分別與電流速斷、限時(shí)電流速斷及過電流保護(hù)相對應(yīng)。①與相鄰線路L4的保護(hù)的?段配合 式中,取,為保護(hù)7的?段末端發(fā)生短路時(shí)對保護(hù)7而言的最小分支系數(shù)。取 。按躲開相鄰變壓器低壓側(cè)出口短路整定:與相鄰線路L4的保護(hù)的?段配合 ;取小者為整定值,即所以斷路器2的整定值為,滿足要求。取 。(3)靈敏性校驗(yàn):不滿足要求。當(dāng)兩個(gè)保護(hù)之間具有分支電路時(shí)(有中性點(diǎn)接地變壓器時(shí)),起動電流整定為 斷路器2斷開,線路L1末端(d6點(diǎn))短路時(shí),即 取較大值作為零序Ш段起動電流,即(2)靈敏度校驗(yàn)作為本線路近后備保護(hù)時(shí),按相鄰線路保護(hù)范圍末端發(fā)生接地故障時(shí)、流過本保護(hù)的最小零序電流來校驗(yàn),要求Klm≥2,即,符合要求。當(dāng)兩個(gè)保護(hù)之間具有分支電路時(shí)(有中性點(diǎn)接地變壓器時(shí)),起動電流整定為 斷路器2斷開,線路L1末端(d6點(diǎn))短