【正文】 定容量(KVA)Sts2廠用變壓器分裂繞組額定容量(KVA)高壓繞組:(200x8%x110%)/= 號%/冷卻方式 186KW 160KW附表3:高備變技術(shù)參數(shù):型3相額定容量高─(低1+低2)低1─低2 對于220KV電壓等級的配電裝置的接線,一般分為兩大類:其一為母線類(包括單母線、單母線分段、雙母線分段和增設(shè)旁路母線的接線);其二為無母線類(包括單元接線、橋型接線和多角型接線等)。⑷、大機組超高壓電氣主接線應(yīng)滿足可靠性的特殊要求。有簡單、清晰、設(shè)備少、投資少、運行操作且有利于擴建等優(yōu)點,但可靠性及靈活性較差。⑶、 雙母線帶旁路接線:雙母線接線可以用母聯(lián)斷路器臨時代替出現(xiàn)斷路器工作,但出線數(shù)目較多時,母聯(lián)斷路器經(jīng)常被占用,降低了工作的可靠性和靈活性,為此可以設(shè)置旁路母線。電廠為區(qū)域性電廠,遠離負荷中心。 雙母線帶旁路接線:每回線路都經(jīng)一臺斷路器和二組隔離開關(guān)分別與二組母線連接,并經(jīng)一組隔離開關(guān)與旁母相連接。單母線帶旁路接線的優(yōu)點:簡單清晰,設(shè)備少,投資小,運行操作方便且利于擴建,其缺點:可靠性、靈活性較差。其優(yōu)缺點如下表所示:優(yōu)點三、短路點的選擇高壓母線上發(fā)生短路:D1發(fā)電機出口發(fā)生短路:D2第一節(jié) 系統(tǒng)各元件電抗標(biāo)幺值的計算:一、選取基準(zhǔn)功率SB=100MVA I*t=4=I N∑2=S N∑2/ 單位:KA總沖擊電流電流基準(zhǔn)值總電流0S有名值 在技術(shù)條件上,選擇的高壓電器能在長期工作條件下和發(fā)生過電壓、過電流的情況下保持正常運行。采用有限流電阻的熔斷器保護的設(shè)備,可不校驗動穩(wěn)定。三、斷路器型號的組成第一個字母表示:S——少油斷路器、D——多油斷路器、K——空氣斷路器、Q——產(chǎn)氣斷路器、L——六氟化硫斷路器、Z——真空斷路器、C——電磁式斷路器第二個字母表示:N——戶內(nèi)用、W——戶外用產(chǎn)品名稱使用環(huán)境SF6氣體壓力即選擇校驗主變至220KV母線處的斷路器。三、隔離開關(guān)型號的組成第一個字母表示:G——隔離開關(guān)、J——接點開關(guān)、第二個字母表示:N——戶內(nèi)用、W——戶外用產(chǎn)品名稱使用環(huán)境額定電流 接地刀閘或接地器的配置(1)為保證電器和母線的檢修安全,35KV及以上每段母線根據(jù)長度宜裝設(shè)1—2組接地刀閘或接地器,每兩接地刀閘間的距離應(yīng)盡量保持適中。(3)當(dāng)需要監(jiān)視和檢測線路側(cè)有無電壓時,出線側(cè)的一相上應(yīng)裝設(shè)電壓互感器。與此對應(yīng),互感器3相總的額定容量為Se2=150VA負荷校驗:電壓互感器的額定二次容量(對應(yīng)于所要求的準(zhǔn)確級)應(yīng)不小于電壓互感器的二次負荷。QVW(Var) 壓無功電度表1由于每相上尚接有絕緣監(jiān)視電壓表V(P0=)+ SVWSin ()]/(3)對直接接地系統(tǒng),一般按三相配置。 式中UN1 IN1為電流互感器一次額定電壓和電流二次額定電流的選擇:有5A和1A兩種,一般弱電系統(tǒng)用1A,強電系統(tǒng)用5A。電流互感器準(zhǔn)確級和額定容量的選擇:為保證測量儀表的準(zhǔn)確度,互感器的準(zhǔn)確級不得低于所供測量儀表的準(zhǔn)確級,且互感器二次所接負荷應(yīng)不大于該準(zhǔn)確級所規(guī)定的額定容量。(2X200~2X600)/5并應(yīng)使CT一次額定電流比正常工作電流大1/3。一般測量儀表與保護裝置宜分別接于不同的二次繞組。 流 熱穩(wěn)定滿足要求。 它們都與架空輸電線路相聯(lián)接,輸電線上的過電壓波會運動至發(fā)、變電所,對電氣設(shè)備構(gòu)成威脅,因此發(fā)、變電所要對侵入波過電壓進行防護,主要手段是避雷器。2)直接接地系統(tǒng)中,變壓器中性點為全絕緣,但變電所為單進線且為單臺變壓器運行時。 額定電壓:146KV母線避雷器:型號:Y10W220/520W(4) 便于擴建和安裝(5) 在保證上述條件要求下,應(yīng)節(jié)約材料、減少投資。第二節(jié) 高壓主接線配電裝置的布置一、主接線配置布置形式的選擇:電氣主接線配電裝置是發(fā)電廠的重要組成部分,是各種電氣設(shè)備及必需的輔助設(shè)備組成的,擔(dān)負著接受、分配和輸出電能的作用。選擇LGJ500/35大于LGJ300/30可不進行電暈校驗。 between Practically all these phenomena disappear if the gas is removed from the space vacuum interrupters makes in possible to install the breakers in space如果空氣通過裂縫進入滅弧室,真空斷路器失靈。因此斷路器中介電強度恢復(fù)的非???。因此,過電壓就可以被限制在正常值內(nèi)。因為金屬蒸汽等離子體是高導(dǎo)電的而且產(chǎn)生的電弧電壓僅為20—200V。 DL 5000—94(中國電力出版社在分斷時,產(chǎn)生的電弧能量是非常小的。因此,最后一個電極處熄滅的電弧也只要15MS。這可避免當(dāng)切斷大電流時產(chǎn)生局部過熱。真空斷路器是由三個真空斷續(xù)器失靈。 swetching boards.When the contact separates,the current to be interrupted initiates a metalvapour arc discharge and flows through this plasma until the next current zero. The arc is the extinguished and the conductive metal vapour condenses withein a matter of microseconds. As a result,the dielectric strength in the break builds up very rapidly. The contact pieces are designed to generate a magnetic field which causes the arc root to rotate. The prevents their local overheating when interrupting large currents. In breakers for very high fault currents (50/63kA), an axial magnetic field ensures that the arc burns diffusely, at every current level,throughout the whole current range.The metal vapour arc discharge can only be maintained if a certain minimum current flows. A current that does not attain this level is chopped prior to current zero. This chopping current must be kept to a minimum in order to proevent unduly high overvoltages building up when inductive circuits are switched. The use of a special contact material ensures that current chopping is limited to 4~5A. Consequently the overvoltages are limited to uncritical values as well.The rapid build up of the dielectric strength enables the arc to be safely extinguished even if contact separation occurs immediately prior to current zero. The maximum arcing time for the last pole to clear is therefore only 15ms.The purpose of the arc quenching device of AC breakers is to deionize the break immediately after current zero. For all convertional arc quenching methods this means that the arc has to be booled even before the contact pieces have reached the minimum quenching distance and before the next current zero,a fact which automatically increases the arc energy. The arc drawen in the vacuum breaker, on the other hand , is not cooled since the metal vapour plasma is highly conductive and the resulting arc voltage only attains values between 20V and 200V. For this reason and because of the short arcing times, the arc energy developed in the bread is very small. This also accounts for the long service life of the vacuum breakers.The contact clearance in the interrupter need only be 6~25mm because under steadystate conditions a pressure of 109 bar suffices to obtain a high dielectric strength.真空斷路器真空開關(guān)提供了另一種電路開斷形式。 reignite. Vacuum breakers fail if parting contacts. This gas is ionized by several different processes and so providesIgmax=(200x1000)/( )=8625A選用圓管形導(dǎo)線(銅材)查《設(shè)計手冊》,其型號為:D=280mm ,d=260mm,t=10mm,δ=25mm,S=7900mm2第七章即所有電器都安裝在同一水平面上內(nèi),并裝在一定高度的基礎(chǔ)上,使帶電部分對地保持必要的高度,以便工作人員能在地面上安全活動,中型配電裝置母線所在的水平面稍高于電器所在的水平面。屋內(nèi)配電裝置是將電氣設(shè)備安裝在屋內(nèi),它的特點是占地面積小,運行維護和操作條件較好,電氣設(shè)備受污穢和氣候條件影響較??;但需建造房屋,投資較大。 滅弧電壓:365KV第六章 各級配電裝置的配置(參考資料:《發(fā)電廠電氣設(shè)備》 于長順 主編 )發(fā)電廠和變電站主接線中,所裝開關(guān)電器、載流導(dǎo)體以及保護和測量電器等設(shè)備,按
點擊復(fù)制文檔內(nèi)容
環(huán)評公示相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1