【正文】 =2657=2126(kVar)考慮線損 5%: =3658(kW)=2232(kVar)K、視在功率計算負(fù)荷:S==4283(KVA)第2章 主變壓器的選擇 主變臺數(shù)的確定變電所中主變壓器的臺數(shù)為一臺或兩臺。60千伏變電站電氣部分設(shè)計方案負(fù)荷計算的內(nèi)容和目的在進(jìn)行變電所設(shè)計時,基本的原始資料以用戶提供的額定容量為設(shè)計依據(jù)。適用于各種范圍的負(fù)荷計算,但計算過程稍繁。對兩臺變壓器的變電所,每臺變壓器的容量按不小于負(fù)荷容量的70%來選擇,當(dāng)一臺主變壓器停運(yùn)時,其余變壓器容量應(yīng)能保證全部負(fù)荷的70%~80%。8%低壓 YN,d11 第3章 無功補(bǔ)償 提高功率因數(shù)的意義(1)減小電力網(wǎng)中輸電線路上有功功率損耗和電能損耗。 功率因數(shù)的計算在沒有考慮低壓母線(10kV)上裝無功補(bǔ)償裝置情況下,只要滿足有關(guān)的參數(shù)即可選擇主變壓器,但根據(jù)設(shè)計要求,則需計算出補(bǔ)償前的變電所平均功率因數(shù),則還需在低壓母線上裝設(shè)無功功率補(bǔ)償裝置,以提高變電所的平均功率因數(shù)。具有發(fā)展和擴(kuò)建的可能性 電氣主接線的選擇為了正確選擇電氣主接線,必須根據(jù)任務(wù)書中指定的設(shè)計原始資料進(jìn)行初步設(shè)計,確定兩個可行方案。當(dāng)線路斷路器或刀閘故障檢修時,將造成線路或變壓器停電。Ⅰ經(jīng)濟(jì)比較 單母線分段與單母線分段帶旁路接線所用一次設(shè)備統(tǒng)計表接線方式斷路器隔離開關(guān)電流互感器電壓互感器避雷器母線單母線分段少少相同相同相同少單母線分段帶旁路多多相同相同相同多:單母線分段較單母線分段帶旁路接線節(jié)設(shè)備。檢修任一斷路器時不中斷對用戶的供電。當(dāng)線路斷路器需要檢修時,可以用備用手車斷路器代用,使線路停電的時間非常短。本次設(shè)計過程,由火電廠和水電廠組成系統(tǒng)網(wǎng)絡(luò),根據(jù)短路電流計算的目的來設(shè)置各元件的連接方式和故障點(diǎn)。其和便是故障點(diǎn)周期電流的有名值。 系統(tǒng)接線圖 等值電路圖計算等值電抗:根據(jù)設(shè)計任務(wù)書中所給條件進(jìn)行元件參數(shù)的計算。(6)按額定開斷電流校驗(yàn):INbr=,I’’=,INbr≥I’’;(7)按額定關(guān)合電流校驗(yàn):INcl=80kA,Ich= ,INclIch。但由于隔離開關(guān)不用來接同和切除短路電流,故無需進(jìn)行開斷電流和短路關(guān)合電流的效驗(yàn)。由以上短路計算得I’’ =(kA),Qk =(kA2S)額定周期分量熱效應(yīng)為:Q=Ir2=202=400(kVar) k經(jīng)校驗(yàn)滿足熱穩(wěn)定要求。電壓互感器二次額定電壓應(yīng)滿足測量、繼電保護(hù)和自動裝置的要求。手動式開關(guān)柜中的斷路器及其他元件設(shè)備可拉出柜外檢修,推入備用可繼續(xù)使用供電。 LDZ1—10型電流互感器主要參數(shù)型號額定電流(kA)準(zhǔn)確級二次組合額定1s短路時熱電流(kA)動穩(wěn)定峰值電流(kA)LDZ1—10400/510P153075(3)熱穩(wěn)定檢驗(yàn):在驗(yàn)算電器的短路熱效應(yīng)時,通常以1S允許通過的熱穩(wěn)定電流進(jìn)行校驗(yàn)。:反應(yīng)變壓器繞組和引出線間的相間短路,安裝在變壓器兩側(cè),縱差保護(hù)是比較流入差動繼電器的差動電流,當(dāng)變壓器兩側(cè)流入繼電器差流為零時,繼電器不動作,當(dāng)差流大于整定值保護(hù)動作跳開主變開關(guān)。首先考慮對兩側(cè)電流進(jìn)行相位補(bǔ)償,然后進(jìn)行數(shù)值補(bǔ)償,才能保證正常運(yùn)行和外部短路時流入繼電器的電流在理想狀態(tài)時等于零。因此,還需要第二次補(bǔ)償,變壓器相間短路的后備保護(hù)和過負(fù)荷保護(hù)一、過電流保護(hù)安裝位置:保護(hù)裝置安裝在變壓器的電源側(cè)。保護(hù)動作時限的選擇和靈敏度校驗(yàn)與定時限過電流保護(hù)相同。以防止過負(fù)荷保護(hù)在外部短路故障及短路過負(fù)荷時誤發(fā)信號。但在土壤電阻大于500的地區(qū),宜裝設(shè)獨(dú)立避雷針。(3)兩針間水平面上保護(hù)范圍的一側(cè)最小寬度按下式計算:當(dāng)時, ()當(dāng)時, ()當(dāng)時, () 兩只等高避雷針保護(hù)范圍2與4的保護(hù)范圍:=同理1與(3#與4#)=2與(1#與4#)= 由防雷保護(hù)范圍計算可知,各相臨避雷針的保護(hù)范圍,所以全部的設(shè)備都在被保護(hù)的范圍之內(nèi),滿足設(shè)計要求。這種接地網(wǎng)的總接地電阻可按下式計算R=+() () 接地網(wǎng)平面圖L是接地體(包括水平的與垂直的)總長度(m)。二次為單母線分段,由于10KV配電裝置選擇了KYN2810型開關(guān)柜,它也是單母線接線,與設(shè)計方案正好吻合,它的配套斷路器是VS110型,所以本設(shè)計也選擇了此型號。在計算中首先計算出各個元件參數(shù),星三角變換,求計算電抗,查表求出短路電抗標(biāo)幺值,最后算出短路電流沖擊值,做為選擇電器用。但本人水平有限,難免會在某些地方有錯誤和遺漏,敬請各位老師批評和指正。wrong39。 this touch potential presents a hazard of electrocution.Transmission substationA transmission substation connects two or more transmission lines. The simplest case is where all transmission lines have the same voltage. In such cases, the substation contains highvoltage switches that allow lines to be connected or isolated for fault clearance or maintenance. A transmission station may have transformers to convert between two transmission voltages, voltage control/power factor correction devices such as capacitors, reactors or static VAr pensators and equipment such as phase shifting transformers to control power flow between two adjacent power systems.Transmission substations can range from simple to plex. A small switching station may be little more than a bus plus some circuit breakers. The largest transmission substations can cover a large area (several acres/hectares) with multiple voltage levels, many circuit breakers and a large amount of protection and control equipment (voltage and current transformers, relays and SCADA systems). Modern substations may be implemented using international standards such as IEC Standard 61850.Distribution substationA distribution substation transfers power from the transmission system to the distribution system of an area. It is uneconomical to directly connect electricity consumers to the main transmission network, unless they use large amounts of power, so the distribution station reduces voltage to a value suitable for local distribution.The input for a distribution substation is typically at least two transmission or subtransmission lines. Input voltage may be, for example, 115在此我要向您誠摯的說一聲,謝謝您!同時,電氣教研室的各位老師也非常熱情地給予我耐心的指導(dǎo)。符合長遠(yuǎn)要求。由此得出如下結(jié)論:負(fù)荷計算采用需要系數(shù)法計算簡潔。垂直接地體一般用角鋼(20 203~50505mm)或鋼管。(詳見防雷保護(hù)圖)對角避雷針間距:由于4只避雷針?biāo)鶉擅娣e為四邊形,所以分成兩個三角形計算。當(dāng)有困難時,該接地裝置可與主接地網(wǎng)連接。過負(fù)荷保護(hù)應(yīng)能反應(yīng)變壓器各繞組的過負(fù)荷情況,對雙繞組降壓變壓器應(yīng)設(shè)在高壓側(cè)。對并列運(yùn)行的變壓器,應(yīng)考慮突然切除一臺時所出現(xiàn)的過負(fù)荷。變壓器三角形側(cè)電流互感器變比: nTA(d)=IN(d) /5 ()變壓器星形側(cè)因?yàn)殡娏骰ジ衅鹘映扇切魏螅媳垭娏鲾U(kuò)大了倍,所以為保證通過穿越性電流時差動回路中無電流,應(yīng)將電流互感器的變比也擴(kuò)大倍。:過流保護(hù)、過負(fù)荷保護(hù)。KYN28—12金屬鎧裝中置式開關(guān)柜(簡稱手車柜),適用于各大、中型變電所3~10kV配電系統(tǒng)中,作為接受和分配電能并對電路實(shí)行控制保護(hù)和監(jiān)測之用。(5)動穩(wěn)定校驗(yàn):所選斷路器極限動穩(wěn)定電流INcl為50kA,其值大于沖擊電流Ich=,即INclIch滿足動穩(wěn)定要求。: JCC5—60型電壓互感器主要參數(shù)型號額定電壓(kV)初級繞組 次級繞組 剩余電壓繞組試驗(yàn)電壓(kv)1min 雷電沖短時工頻 擊全波二次負(fù)荷 剩余電壓繞組輸出 準(zhǔn)確級(kV)JCC5—60 140 250150 250100 3P 10kV側(cè)電壓互感器的選擇電壓互感器選擇是根據(jù)額定電壓選擇。 LDZ1—10型電流互感器主要參數(shù)型號額定電流(kA)準(zhǔn)確級級次組合額定1s短路時熱電流(kA)動穩(wěn)定峰值電流(kA)LDZ1—10800/545115(3)熱穩(wěn)定檢驗(yàn):在驗(yàn)算電器的短路熱效應(yīng)時,通常以1S允許通過的熱穩(wěn)定電流進(jìn)行校驗(yàn)。(4)動穩(wěn)定校驗(yàn):所選斷路器極限動穩(wěn)定電流INcl為80kV,其值大于沖擊電流Ich=,即INclIch滿足動穩(wěn)定要求。(5)動穩(wěn)定校驗(yàn):所選斷路器額定動穩(wěn)定電流峰值INcl為100kA,其值大于沖擊電流Ich=,即INclIch滿足動穩(wěn)定要求。: K3點(diǎn)發(fā)生三相短路等值網(wǎng)絡(luò)圖其中: X16=X14+X9+=++= X17=X15+X9+=++=計算電抗: X=X16== X=X17= =17,所以系統(tǒng)供給的三相短路電流周期分量不隨時間而衰減,其值為: I*1== I*2==經(jīng)過查運(yùn)算曲線可得:汽輪發(fā)電機(jī)供給的三相短路電流周期分量標(biāo)幺值為: I1(0)= 2S時: I1(2)= 4S時: I1(4)= 水輪發(fā)電機(jī)供給的三相短路電流周期分量標(biāo)幺值為:I2(0)= 2S時: I2(2)= 4S時: I2(4)= 歸算至短路點(diǎn)電壓等級各等值電源的基準(zhǔn)電流為: IN∑1=== (kA) IN∑2=== (kA)計算10kV側(cè)三相短路點(diǎn)K3(3)的三相短路電流周期分量有名值為:(次暫態(tài))I(0)=I*1(0)IN∑1+ I2(0)IN∑2=+= (kA) 2S時: I(2)=I*1(2)IN∑1+ I2(2)IN∑2=+= (kA)4S時: I(4)=I*1(4)IN∑1+ I2(4)IN∑2=+= (kA)所以,短路沖擊電流為:iimp= I(0) ==(kA)短路電流的最大有效值為: Iimp= I(0)= 1’71=(kA) 第6章 電氣設(shè)備的選擇與校驗(yàn) 斷路器的選擇 60kV側(cè)斷路器的選擇根據(jù)安裝地點(diǎn)的工作電壓,最大長期工作電流選擇(1)額定電壓 (kV)(2)最大長期工作電流為:max===(kA)根據(jù)額定電壓和最大長期工作電流的計算數(shù)據(jù),查電氣設(shè)備選擇工具書可選擇—63型斷路器為60kV側(cè)的高壓斷路器,: LW963高壓斷路器主要參數(shù)型 號額定電壓(kV)額定電流(kA)額定開斷電流(kA)額定關(guān)合電流峰值(kA)4s短路時承受電流(KA)額定動穩(wěn)定電流峰值(kA)
點(diǎn)擊復(fù)制文檔內(nèi)容
公司管理相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1