freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

10kv降壓變電所畢業(yè)論文(存儲(chǔ)版)

2025-07-28 07:05上一頁面

下一頁面
  

【正文】 稱的短路電流分解為對(duì)稱的正序、負(fù)序、和零序分量,然后按對(duì)稱量進(jìn)行分析和計(jì)算。 短路計(jì)算等效電路、 K1點(diǎn)()的相關(guān)計(jì)算1) 總電抗標(biāo)幺值=+= (式67)2) 三相短路電流周期分量有效值 (式68)3) 其他短路電流① 三相短路次暫態(tài)電流和穩(wěn)態(tài)電流 (式69)② 三相短路沖擊電流及第一個(gè)周期短路全電流有效值 (式610) (式611)4) 三相短路容量 (式612) 、K2點(diǎn)()的相關(guān)計(jì)算兩臺(tái)變壓器并列運(yùn)行時(shí):1) 總電抗標(biāo)幺值=++=2) 三相短路電流周期分量有效值3) 其他短路電流① 三相短路次暫態(tài)電流和穩(wěn)態(tài)電流② 三相短路沖擊電流及第一個(gè)周期短路全電流有效值4) 三相短路容量?jī)膳_(tái)變壓器分列運(yùn)行時(shí)1) 總電抗標(biāo)幺值=++=2) 三相短路電流周期分量有效值3) 其他短路電流① 三相短路次暫態(tài)電流和穩(wěn)態(tài)電流② 三相短路沖擊電流及第一個(gè)周期短路全電流有效值4) 三相短路容量以上短路計(jì)算結(jié)果綜合如圖表61所示。常用的斷路器類型主要有少油斷路器、真空斷路器、SF6斷路器,由于真空斷路器、SF6斷路器技術(shù)特性比較好,少油斷路器已經(jīng)逐漸被它們代替。繪制斷路器的校驗(yàn)表,如表72所示。表74 隔離開關(guān)選擇校驗(yàn)表序號(hào)裝設(shè)地點(diǎn)的電氣條件ZN310/630A8型斷路器項(xiàng)目數(shù)據(jù)項(xiàng)目數(shù)據(jù)結(jié)論1UN10kV10kV合格2I30630A合格3Ish(3)50kA合格4(I∞3)2timaIt2t2022=800合格、 高壓熔斷器的選擇與校驗(yàn)表75 RN210/額定電壓額定熔體電流額定開斷電流/KV/A/KA1050 高壓側(cè)熔斷器用作高壓電壓互感器一次側(cè)的短路保護(hù),擬選用RN210/。繪制斷路器的校驗(yàn)表,如表77所示。經(jīng)校驗(yàn)所選接地開關(guān)是合格的。、低壓電氣設(shè)備選擇與校驗(yàn)由于根據(jù)《低壓一次設(shè)備的選擇校驗(yàn)項(xiàng)目和條件》進(jìn)行的低壓一次側(cè)設(shè)備選擇,不需再對(duì)熔斷器、路器進(jìn)行校驗(yàn)。、電流互感器選擇與校驗(yàn)(1) 1500/5A型低壓電流互感器(2)。根據(jù)設(shè)計(jì)經(jīng)驗(yàn):一般10KV及以下的高壓線路和低壓動(dòng)力線路,通常先按發(fā)熱條件選擇導(dǎo)線和電纜截面,再校驗(yàn)其電壓損耗和機(jī)械強(qiáng)度。查表的該電纜的熱穩(wěn)定系數(shù),,校驗(yàn)熱穩(wěn)定性: 滿足熱穩(wěn)定性要求。動(dòng)穩(wěn)定度校驗(yàn)TMY母線材料的最大允許應(yīng)力 三相短路時(shí)所受的最大動(dòng)力:母線的彎曲力矩(母線檔數(shù)為3):母線的截面系數(shù): 母線在三相短路時(shí)的計(jì)算應(yīng)力: 所以, 滿足動(dòng)穩(wěn)定度要求。但是根據(jù)實(shí)際經(jīng)驗(yàn),N線截面可選為。滿足發(fā)熱條件,故選。綜上可知,倉(cāng)庫(kù)所選的導(dǎo)線型號(hào)和規(guī)格可表示為VV221KV350+125。(b)N線截面的選擇 按,選。1)電鍍車間的計(jì)算電流:2)按發(fā)熱條件選擇導(dǎo)線的截面(a)相線截面的選擇截面為的VV221KV型銅芯電纜直埋時(shí)的載流量為261A,。(b)N線截面的選擇 按,選。綜上可知,鍛壓車間所選的導(dǎo)線型號(hào)和規(guī)格可表示為VV221KV3150+170。表713 低壓電纜的選擇廠房名稱電纜線型號(hào)允許載流量金工車間VV221KV3150+170Ial=303A(直埋)機(jī)修車間VV221KV395+150Ial=236A(直埋)鍋爐車間VV221KV3120+170Ial=269A(直埋)倉(cāng)庫(kù)VV221KV350+125Ial=158A(直埋)裝配車間VV221KV3120+170Ial=269A(直埋)工具車間VV221KV3150+170Ial=303A(直埋)熱處理車間VV221KV3185+195Ial=340A(直埋)電鍍車間VV221KV3120+170兩根并聯(lián);Ial=2692=538(直埋)鑄造車間VV221KV395+150兩根并聯(lián);Ial=2362=472(直埋)鍛壓車間VV221KV3150+170Ial=303A(直埋)生活區(qū)VV221KV3185+195兩根并聯(lián);Ial=3402=680A(直埋)第八章 變電所二次回路方案選擇及繼電保護(hù)的整定在各級(jí)電壓等級(jí)的變電所中,使用各種電氣設(shè)備,諸如變壓器、斷路器、隔離開關(guān)、電流互感器、電壓互感器、母線、補(bǔ)償電容器等,這些設(shè)備的任務(wù)是保證變電所安全、可靠的供電,因?yàn)檫x擇電氣設(shè)備時(shí),必須慮及電力系統(tǒng)在正常和故障時(shí)的工作情況。結(jié)合上面設(shè)備的選擇和電源選擇,采用彈簧操作機(jī)構(gòu)的斷路器控制和信號(hào)回路。、二次回路接線要求繼電保護(hù)裝置即各種不同類型的繼電器,以一定的方式連結(jié)與組合,在系統(tǒng)發(fā)生故障時(shí),繼電保護(hù)動(dòng)作,作用于斷路器脫扣線圈或給出報(bào)警信號(hào),以達(dá)到對(duì)系統(tǒng)進(jìn)行保護(hù)的目的。繼電保護(hù)裝置的接線方式采用兩相兩繼電器式接線;繼電保護(hù)裝置的操作方式采用交流操作電源供電中的“去分流跳閘”操作方式(接線簡(jiǎn)單,靈敏可靠);帶時(shí)限過電流保護(hù)采用反時(shí)限過電流保護(hù)裝置。2) 過電流保護(hù)動(dòng)作時(shí)限的整定:由于此變電所為終端變電所。下面對(duì)高壓母線處的過電流保護(hù)裝置進(jìn)行整定。過電流保護(hù)靈敏度系數(shù)因無臨近單位變電所10kV母線經(jīng)聯(lián)絡(luò)線到本廠變電所低壓母線的短路數(shù)據(jù),無法檢驗(yàn)靈敏度系數(shù),只有從略??筛鶕?jù)以上整定要求,參考相關(guān)產(chǎn)品資料對(duì)低壓側(cè)的ACB和MCCB系列低壓斷路器進(jìn)行整定,在此不詳述。如變電所的主變壓器裝在室外或有露天配電裝置時(shí),則應(yīng)在變電所外面的適當(dāng)位置裝設(shè)獨(dú)立避雷針,其裝設(shè)高度應(yīng)使其防雷保護(hù)范圍包圍整個(gè)變電所。、雷電侵入波的防護(hù) 1)在10KV電源進(jìn)線的終端桿上裝設(shè)FS4—10型閥式避雷器。b)計(jì)算單根鋼管的接地電阻查《工廠供電》附錄表25,得砂質(zhì)粘土的。綜上設(shè)計(jì),作出變電所的電氣平面布置圖以及變電所接地裝置平面圖。與此同時(shí)我的計(jì)算機(jī)應(yīng)用水平也有了一定的提升。同時(shí),在本次設(shè)計(jì)中同組的同學(xué)們也給了我很大的幫助,我們之間的相互討論和幫助也是本次畢業(yè)設(shè)計(jì)能順利完成的一個(gè)關(guān)鍵所在,所以在此再次向各位老師和各位同學(xué)表示衷心的感謝!附錄A:外文資料翻譯Substation integrated automation systemIn recent years, as the level of power grid operations increased levels dispatch center to ask for more information, to grasp power grid and the operation of the substation and improve substation controllability, then ask for more focused use of remote control, operation, antiaccident measures, namely Unattended mode of management. to improve labor productivity, reduce the possibility of human error in their operation and improve the reliability. The other hand, the contemporary puter technology, munication technology and other advanced technological means of application, has changed the traditional model of secondary equipment to simplify the system, information sharing, reducing cable, reducing size, lowering the cost has changed the face of the substation operation. For the above reasons, substation automation from hot topic has been shifted to the practical stage, Power industry departments put。經(jīng)過收集資料、設(shè)計(jì)、繪圖、審核的整個(gè)過程完成了本次設(shè)計(jì)。變電所的變壓器室有兩條接地干線、高低壓配電室各有一條接地干線與室外公共接地裝置焊接相連,接地干線均采用25 mm 4 mm的鍍鋅扁剛。、接地裝置的設(shè)計(jì) a)接地裝置的初步方案現(xiàn)初步考慮圍繞變電所建筑三面,距變電所外墻2~3m,打入一圈直徑50mm、每隔5m打入一根(為減小接地電流的屏蔽效應(yīng),管距一般不宜小于管長(zhǎng)的2倍)。避雷針采用直徑20mm的鍍鋅扁剛,長(zhǎng)1~。實(shí)際運(yùn)行表明,對(duì)于變配電所防直擊雷的保護(hù)避雷針和避雷器是很有效的,雷電波入侵則必須裝設(shè)閥型避雷器保護(hù),防雷保護(hù)涉及應(yīng)認(rèn)真調(diào)查地質(zhì)地貌氣象環(huán)境等條件和雷電的活動(dòng)規(guī)律,以及被保護(hù)物的特點(diǎn)等,因地制宜地采取防雷保護(hù)措施,做到安全可靠、技術(shù)先進(jìn)、經(jīng)濟(jì)合理等。d)過流脫扣器與被保護(hù)線路配合要求: 滿足:, (式811):絕緣導(dǎo)線和電纜允許短時(shí)過負(fù)荷倍數(shù)(對(duì)瞬時(shí)和短延時(shí)過流脫扣器,;對(duì)長(zhǎng)延時(shí)過流脫扣器,~)。過電流保護(hù)動(dòng)作電流的整定,利用式,其中 , ,因此動(dòng)作電流為: 因此過電流保護(hù)動(dòng)作電流整定為9A。 、10KV側(cè)繼電保護(hù)繼電保護(hù)在此選用GL25/10型繼電器。本設(shè)計(jì)變壓器保護(hù)采用微機(jī)裝置GYR100T下面整定該繼電器的動(dòng)作電流,動(dòng)作時(shí)限和速斷電流倍數(shù)。由于本廠的高壓線路不很長(zhǎng),容量不很大,因此繼電保護(hù)裝置比較簡(jiǎn)單。(5)低壓動(dòng)力線路:裝設(shè)電流表一只。這里采用交流操作電源。該型號(hào)的載流量為340A。(b)N線截面的選擇 按,選。1)鑄造車間的計(jì)算電流:2)按發(fā)熱條件選擇導(dǎo)線的截面(a)相線截面的選擇截面為的VV221KV型銅芯電纜直埋時(shí)的載流量為221A,。但是根據(jù)實(shí)際經(jīng)驗(yàn),N線截面可選為。1)工具車間的計(jì)算電流:2)按發(fā)熱條件選擇導(dǎo)線的截面(a)相線截面的選擇截面為的VV221KV型銅芯電纜直埋時(shí)的載流量為296A,。(b)N線截面的選擇 按,選。綜上可知,機(jī)修車間所選的導(dǎo)線型號(hào)和規(guī)格可表示為VV221KV395+150。滿足發(fā)熱條件,故選。、 按載流量選擇TMY4(1008)矩形銅母線,該母線最高工作溫度為700C,水平平放,檔距為900mm,檔數(shù)為3,相鄰兩相的軸線距離為160mm,允許載流量。該電纜纜芯最高工作溫度為900C,允許載流量為182A。該開關(guān)柜的尺寸為2200 mm(高)1000 mm(寬)800mm(深)。該熔斷器具有功率損耗小,分?jǐn)嗄芰Ω?,特性穩(wěn)定,限流性能好,體積小等優(yōu)點(diǎn)。、高壓開關(guān)柜的選擇參考以上設(shè)備選擇,考慮以后發(fā)展,選擇KYN2812型鎧裝移開式金屬封閉開關(guān)柜。,滿足保護(hù)要求本設(shè)計(jì)擬選用JN1512/,該接地開關(guān)的主要技術(shù)參數(shù)如表79所示。動(dòng)穩(wěn)定度校驗(yàn)即滿足動(dòng)穩(wěn)定的條件: 或 代入數(shù)據(jù)得: ;滿足動(dòng)穩(wěn)定的度條件。經(jīng)上述的校驗(yàn)所選的隔離開關(guān)是合格的。動(dòng)穩(wěn)定度校驗(yàn)即滿足動(dòng)穩(wěn)定的條件: 或 代入數(shù)據(jù)得: ;滿足動(dòng)穩(wěn)定的度條件。 ,—— 設(shè)備允許的通過的極限電流峰值和有效值。、短路電流的計(jì)算及匯總表、 繪制計(jì)算電路,采用一路電源供線,以距本廠8km的饋電變電站經(jīng)LGJ185架空線(備用采用鄰廠高壓聯(lián)絡(luò)線),該干線首段所裝高壓斷路器的斷流容量為500MVA計(jì)算K1點(diǎn)和K2點(diǎn)的短路電流和短路容量。同時(shí),為了選擇切除短路故障的開關(guān)電器、整定短路保護(hù)的繼電保護(hù)裝置和選擇限制短路電流的元件等,也必須計(jì)算短路電流。短路的后果有以下幾點(diǎn)1) 短路電流的熱效應(yīng)。、低壓?jiǎn)文妇€不分段以上三種方案均能滿足主接線要求,采用三方案時(shí)雖經(jīng)濟(jì)性最佳,但是其可靠性相比其他兩方案差;采用方案二需要的斷路器數(shù)量多,接線復(fù)雜,它們的經(jīng)濟(jì)性能較差;采用方案一既滿足負(fù)荷供電要求又較經(jīng)濟(jì),故本次設(shè)計(jì)選用方案一。優(yōu)點(diǎn):用斷路器把母線分段后,對(duì)重要用戶可以從不同母線段引出兩個(gè)回路, 用兩個(gè)電路供電;當(dāng)一段母線故障時(shí),分段斷路器自動(dòng)切除故障母線保證正常段母線不間斷供電和不致使重要用戶停電 。能適應(yīng)各種不同的運(yùn)行方式,以便于操作和檢修,并能適應(yīng)負(fù)荷發(fā)展。對(duì)一級(jí)用電負(fù)荷,必須有兩個(gè)獨(dú)立電源供電。b)裝設(shè)兩臺(tái)變壓器 型號(hào)為S9型,而每臺(tái)變壓器容量根據(jù)式(41)、(42)選擇,即 (式41)≥=(++) KVA= KVA (式42)因此選兩臺(tái)S91000/10型低損耗配電變壓器。、負(fù)荷中心的確定、負(fù)荷指示圖負(fù)荷指示圖是將電力負(fù)荷(計(jì)算負(fù)荷P30)按一定比例K(例如以1mm面積代表若干kW)用負(fù)荷圓的形式標(biāo)示在企業(yè)或車間的平面圖上。表22 無功補(bǔ)償后工廠的計(jì)算負(fù)荷項(xiàng)目
點(diǎn)擊復(fù)制文檔內(nèi)容
教學(xué)教案相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1