【正文】
gn needs to consider the following points: ① question of how much reserve power, lighting and electricity, which according to GB500342020 Architectural Lighting Design Standards table of Article and , mercial building lighting power density value, highend supermarkets, business offices as 20W/m2, under the decorative lighting included 50% of the total lighting power density calculation requirements, using the reserved standard 40W/m2. ② In order to facilitate the decoration in each partition set fire lighting in public areas and emergency lighting distribution box distribution box, in order to identify the electrical power distribution decoration cutoff point. ③ the staircase, storage rooms and other parts of the decoration does not need to do, set the power distribution circuit or a separate distribution box, try not to be reserved from the public area of electricity distribution board fed hardcover out. ④ control of lighting in public areas, the majority in two ways, namely, CBUS control system or the BA system, the use of CBUS has the advantage of more flexible control, each road can be fed out of control, adjustable light control。項目組成為:辦公樓兩座,建筑面積為70800m2, 28 層,標準層高為 。 3 變電所設置 根據(jù)負荷計算結果,本工程的變壓器總安裝容量為 ,經(jīng)與供電公司反復協(xié)商,分別在本工程的北、中和南三段設置 3 個變電所為三段建筑供電,1變電所設 6 臺 變壓器 ,承擔北段供電; 2變電所設 4 臺 變壓器 ,加 6 臺 變壓器 ,承擔中段的供電,另外還有 5 臺 高壓冷水機組(合計 ); 3變電所設 2 臺 加 2 臺 變壓器,承擔南段 A、 B 兩座辦公樓供電。根據(jù)這一特點,在設計中較多地使用了插接母線供電,既可以滿足大載流量的要求,又使供配電靈活性加大,在每層豎井中均預留備用插接箱,以便在變化時 ,可根據(jù)上下層負荷的變化,進行調整。此處 的設計需要考慮以下幾點: ① 電量預留多少的問題,其中照明用電可根據(jù) GB500342020 《建筑照明設計標準》表 及其 條,商業(yè)建筑照明功率密度值計算,高檔超市營業(yè)廳為 20W/m2,根據(jù) “裝飾性燈具總功率 50%計入照明密度計算值 ”的規(guī)定,采用的預留標準為 40W/m2。本工程有 3 個 10Kv 變電所, 20 臺變壓器,上百臺低壓饋出柜,饋出回路更多。低壓饋出回路的編號采用了如: W3—6—AL—1—A1,W3—6)表示此回路由 3 號變壓器所供電的 6 號配電柜饋出, AL—1—A1 表示本回路所接的第一個配電箱為 AL—1—A1 等,以此類推。地下部分基本為車庫,用途比較單一,防火分區(qū)也比較整齊,按防火分區(qū)編號,如 AL—BL—1/AP 與 APE 等各字母及數(shù)字含義: AL 代表照明配電箱( AP 代表動力配電箱,APE 代表應急動力配電箱); BI 代表地下一層; 1/1 代表 I 防火分區(qū) 1 號箱。本工程的做法是在電表箱內(nèi)增加一個斷路器為風機盤管供電,另一路為用戶二次設計時使用,如下圖所示。在設計時,采用了就近原則,同時也考慮到整條干線負擔的負荷情況,盡量使各個豎井內(nèi)負荷比較平衡。在本設計中,采用了增加一級配電的方法,即從變電所不同母線段上分別饋出一條消防專用回路,在適當位置設置兩臺配電柜,再由此配電柜放射式配至末端雙電源互投箱,這樣既滿足了規(guī)范對專用供電回路的要求,又避免在變電所級饋出許多小電流回路。一般采用需要系數(shù)法,計算過程不再贅述。本文結合工程實例,介紹了高層建筑電氣設計中一些比較典型且具有普遍意義的問題,結合某工程的實際做法闡述了問題的解決方法。 in the bus and the transformer circuit breaker according to the choice of the general framework of values to select . For example: Route certain equipment capacity 530Kv, Kx take to calculate current of 704A, select the frame circuit breaker is 1000A, tuning is 800A。 distribution。 and different levels of economic development between cities is not balanced, power indices are also different。 shortings is a higher cost. BA system control advantages of using low cost, simple control。 2 負荷計算 1)負荷特點 :用電負荷大 ,遠大于《全國民用建筑工程設計術措施》中大120W/m2 的指標 ,尤其是餐飲的用電負荷更大,而且不同類型、不同飲食文化背景的餐飲差別也很大。本工程配置兩處 10Kv 電源引入點,每處為兩路 10Kv線路 ,根據(jù)供電公司對 10Kv電源容量的規(guī)定:每路最大負荷為 左右,兩路即為 ,設計 3變電所合用一處 10Kv,電源進線,總容量為 ; 2變電所內(nèi)變壓器和 10Kv,冷水機組共用一處 10Kv 電源進線,總容量為 。例如:某豎井一段母線負責 1~ 3 層供電,當 1 層由于變化容量增大,而 3 層容量減小時,就可使用 1 層的備用插接箱把 3 層富裕的容量配給 1 層使用。 ② 為方便裝修設計,在每個防火分區(qū)內(nèi)設置了公共區(qū)域照明配電箱和應急照明配電箱,以便明確裝修設計的電氣配電分界點。按照國際電工委員會( IEC)及中國國標的要求: ① 所有的配電編號要簡單明了,不能太箱和線路編號不重復。 10 結束語 隨著商業(yè)設計項目越來越復雜,需要設計人員不斷地提高設計水平,精心設計,作出精品。根據(jù)以