【正文】
b一一主變壓器外廓寬度(M)。當(dāng)設(shè)有容納20%的油量的貯油池時(shí),變電站內(nèi)還應(yīng)設(shè)置按最大一個(gè)油箱60%的地下總事故油池。按照規(guī)定選擇變壓器的容量、電壓等級不同而有所區(qū)別,存在不合理的地方。但不能帶電作業(yè)污染及抗震性能防污性能差,抗震性能好防污及抗震性能均較差防污及抗震性能均差防污性能較好而抗震性能較差由上表65可見,各型110kV配電裝置中屋外半高型能大幅度節(jié)約用地,能滿足施工、運(yùn)行和檢修的要求,并由多年的運(yùn)行經(jīng)驗(yàn),各型經(jīng)濟(jì)指標(biāo)也較先進(jìn)。表65 110kV配電部分經(jīng)濟(jì)分析[4]比較項(xiàng)目布置形式屋外普通中型屋外半高型屋外高型屋內(nèi)型占地面積%10040總投資%100鋼材消耗%100113水泥消耗%100導(dǎo)線消耗%100電纜%100施工土建施工及安裝調(diào)整方便。采用SF6組合電器:將斷路器、電力互感器和隔離開關(guān)三者組合在一起,可以有效的壓縮占地面積,其壓縮面積可達(dá)40%。%,可見效果十分顯著。其優(yōu)點(diǎn)是巡視、檢修方便,但配電裝置的寬度較大,占地多,土石方量大。母線原設(shè)計(jì)采用鋁管,施工時(shí)改為LGJQ400型鋼芯鋁絞線。(2)貯油坑應(yīng)有排油管,以保證在發(fā)生設(shè)備事故時(shí),迅速將油排至安全處所。遮攔應(yīng)有門鎖,網(wǎng)孔不應(yīng)大于2020mm。(13)當(dāng)電廠具有二級升高電壓配電裝置時(shí),一般要預(yù)留安裝第二臺三卷變壓器的位置和引線走廊。25m。(6)當(dāng)防爆走廊長度超過40m時(shí),應(yīng)以帶門的非燃性隔墻隔開。(4)配電裝置長度在7m以內(nèi)時(shí)允許只有一個(gè)出口,長度大于7m時(shí)至少應(yīng)有兩個(gè)出口,且每兩個(gè)出口間距離不超過60m。5.對于35kV~110kV屋外配電裝置,當(dāng)結(jié)線比較簡單時(shí),一般采用帶“隔離插頭”的布置。同時(shí)要注意防洪和滑坡等問題。(5)陡波沖擊電流的殘壓其中BIL’為110kV側(cè)內(nèi)絕緣截?cái)嗬纂姏_擊耐受電壓為530kV。 3.母線的選擇:(1) 其中Ig為負(fù)載的長時(shí)最大工作電流,若進(jìn)線在母線中間時(shí),~[7]。②熱穩(wěn)定校驗(yàn)110kV側(cè)的短路熱容量為:SW4110G型斷路器的4s熱穩(wěn)定電流為:21kAIt2t=2124=1764 kA2SQk< It2t符合要求。(5)陡波沖擊電流的殘壓其中BIL’為35kV側(cè)內(nèi)絕緣截?cái)嗬纂姏_擊耐受電壓為220kV。3.母線的選擇:(1) 其中Ig為負(fù)載的長時(shí)最大工作電流,若進(jìn)線在母線中間時(shí),~。②熱穩(wěn)定校驗(yàn)35kV側(cè)的短路熱容量為:SW435I型斷路器的4s熱穩(wěn)定電流為:It2t=4=1089 kA2SQk< It2t符合要求。(5)陡波沖擊電流的殘壓其中BIL’為10kV側(cè)內(nèi)絕緣截?cái)嗬纂姏_擊耐受電壓為85kV。3.母線的選擇:(1) 其中Ig為負(fù)載的長時(shí)最大工作電流,若進(jìn)線在母線中間時(shí),~。②熱穩(wěn)定校驗(yàn)10kV側(cè)的短路熱容量為:SN1010III型斷路器的4s熱穩(wěn)定電流為:40kAIt2t=4024=6400 kA2SQk< It2t符合要求。按本工程設(shè)計(jì)最終容量計(jì)算,并考慮電力系統(tǒng)遠(yuǎn)景發(fā)展規(guī)劃;其接線采用可能發(fā)生最大短路電流的正常接線方式,但不考慮在切換過程中可能短時(shí)并列的接線方式。(1)短路熱穩(wěn)定校驗(yàn)短路電流通過電器時(shí),電氣設(shè)備各部件溫度應(yīng)不超過允許值。1.按正常工作條件選擇電氣設(shè)備(1)額定電壓電氣設(shè)備所在電網(wǎng)的運(yùn)行電壓因調(diào)壓或負(fù)荷的變化,有時(shí)會高于電網(wǎng)的額定電壓,故所選電氣設(shè)備允許的最高工作電壓不得低于所接電網(wǎng)的最高運(yùn)行電壓。5.計(jì)算1000kV以下低壓電網(wǎng)短路電流時(shí),一般不允許忽略短路回路中電氣設(shè)備的電阻值,如配電變壓器的電阻,低壓線路的電阻,不太長的母線和電纜,電流互感器的一次繞組,自動開關(guān)的過電流線圈及自動開關(guān)和隔離開關(guān)觸頭的接觸電阻等,因?yàn)檫@些電阻對低壓短路電流都有影響。在這樣的系統(tǒng)內(nèi),當(dāng)某處發(fā)生短路時(shí),電源電壓維持不變,即短路電流周期分量在整個(gè)短路過程中不衰減[14]。同時(shí)又力求節(jié)約資金,這就需要按短路情況進(jìn)行全面校驗(yàn)。該型直流系統(tǒng)是模塊化設(shè)計(jì),N+1熱備份。第三章 所用變與直流系統(tǒng) 所用電接線變電站站用母線采用單母線接線方式。因?yàn)榇ㄗ冸娝?0kV出線有Ⅰ、Ⅱ類負(fù)荷。③110~220 kV配電裝置出線回路數(shù)為5回及以上時(shí);或當(dāng)110~220 kV配電裝置在系統(tǒng)中居重要地位,出線回路數(shù)為4回及以上時(shí)。當(dāng)有雙架空線路時(shí),可以順序布置,以致連接不同的母線段時(shí),不會如單母分段那樣導(dǎo)致出線交叉跨越。②3563kV配電裝置出線回路數(shù)為48回時(shí)。單母線可用隔離開關(guān)分段,但當(dāng)一段母線故障時(shí),全部母線仍需短時(shí)停電,在用隔離開關(guān)將故障的母線段分開后才能恢復(fù)非故障段的供電。(2)變電所主變壓器臺數(shù)的確定主變臺數(shù)確定的要求:①對大城市郊區(qū)的一次變電站,在中、低壓側(cè)已構(gòu)成環(huán)網(wǎng)的情況下,變電站以裝設(shè)兩臺主變壓器為宜。復(fù)雜的接線不僅不便于操作,還往往會造成運(yùn)行人員的誤操作而發(fā)生事故。(2)變電所的分期和最終建設(shè)規(guī)模。最大負(fù)荷利用小時(shí)為4000h,一類負(fù)荷占最大負(fù)荷的20%,二類負(fù)荷占20%,其余為三類負(fù)荷。有兩端供電、環(huán)式、鏈?zhǔn)降取?2)保證良好的電能質(zhì)量。(3)電力系統(tǒng)的發(fā)展和國民經(jīng)濟(jì)的發(fā)展密切相關(guān)。1949年以前,有154kV,220kV等電壓等級。同一電力系統(tǒng)中電力線路往往有幾種不同電壓等級。電力系統(tǒng)的總裝機(jī)容量指該系統(tǒng)中實(shí)際安裝的發(fā)電機(jī)組額定有功功率的總和,以千瓦(kW)、兆瓦(MW)、吉瓦(GW)計(jì)。關(guān)鍵字 變電所 短路電流計(jì)算 變壓器 電氣設(shè)備AbstractRequest according to design specification, capital the connection diagram designing that the first step designs, and draw the electricity host for 110 kV substation electricity once parts time and their his drawing sheet. That transformer substation is set up having two host transformers, the station inner host works a telephone switchboard dividing 110 kV , 35 kV ,10 kV three voltage grades , one by one, the voltage grade adopt the bridge shape to work a telephone switchboard respectively , Shan bus bar paragraph division takes other mother connection and Shan bus bar paragraph division to work a telephone switchboard , designs the design including electric part and repeated part and secretly schemes against. In a part, want the analysis carrying out population on electric system and the transformer substation, choice ascertaining transformer substation electricity host connection form then, and carrying out systematic idle work pensation , secretly scheme against and electric equipment of shortcircuit current here in process. Arrangement wanting to be to build a transformer substation to carry out the power distribution device and the general flat surface of electricity too in the queen who secretly schemes against concretely, designs , makes rationalization build a station. In repeated part, want the choice considering the way and short circuit point that way , system protecting run synthetically, the adjusting being in progress here on the basis secretly schemes against. Need to draw the relevance drawing sheet in the process of design , include more important drawing sheet such as host connection and grasp whose content.This time design middle be in progress electricity host work a telephone switchboard design, shortcircuit current secretly scheme against, main electric accessory choose and checking (including breaker, disconnector, electric current mutual inductance implement, voltage mutual inductance implement, bus bar and so on), every voltage grade power distribution device design, directcurrent system design and lightning protection protection allocation.Keywords Substation Shortcircuit current secretly schemes against Transformer Electric accessory目 錄摘要 IAbstract II第一章 緒 論 1 電力系統(tǒng)概述 1 電力工業(yè)概況 1 2 2 3 本變電所各級電壓負(fù)荷情況分析 4 變電所的自然條件 4第二章 電氣主接線 5 電氣主接線設(shè)計(jì)的基本要求 5 主變壓器臺數(shù)、容量、型式的選擇 6 電氣主接線方案設(shè)計(jì) 7 變電所電氣主接線特點(diǎn) 9第三章 所用變與直流系統(tǒng) 11 所用電接線 1容量選擇 11 直流系統(tǒng) 12第四章 短路電流計(jì)算 13 13 短路電流計(jì)算條件 13 短路電流計(jì)算方法與步驟 15 變電所三相短路電流計(jì)算 16第五章 電氣設(shè)備選擇 18 電氣設(shè)備選擇一般條件 18 10kV配電裝置電氣設(shè)備選擇 20 35kV配電裝置電氣設(shè)備選擇 27 110kV配電裝置電氣設(shè)備選擇 34第六章 電氣布置 42 配電裝置布置要求 42 配電裝置總要求 42 屋內(nèi)配電裝置的一般要求 43 屋外配電裝置的一般要求 44 配電裝置分類 47 變壓器的布置要求 51第七章 變電所過電壓保護(hù) 53 53 54 保護(hù)措施 54 進(jìn)線保護(hù) 55 變壓器及電氣設(shè)備的保護(hù) 56 避雷器的選擇 58 59第八章 繼電保護(hù)整定計(jì)算 61 61 繼電保護(hù)整定計(jì)算的基本任務(wù) 61 整定計(jì)算的準(zhǔn)備工作和步驟 62 整定計(jì)算 63社會經(jīng)濟(jì)效益分析 66結(jié)論 67致謝 68參考文獻(xiàn) 69附錄1 70附錄2 72附錄3 7483第一章 緒 論 電力系統(tǒng)概述 電力工業(yè)概況1831年法拉第電磁感應(yīng)定律,為發(fā)電機(jī)的發(fā)明創(chuàng)造了前提條件。110kV變電站畢業(yè)設(shè)計(jì)摘 要根據(jù)設(shè)計(jì)任務(wù)書的要求,本次設(shè)計(jì)為110kV 變電所電氣一次部分初步設(shè)計(jì),并繪制電氣主接線圖及其他圖紙。1875年法國在巴黎北火車站建立了世界上第一座發(fā)電廠,專供弧光燈照明用電。所謂最高電壓等級,是指該系統(tǒng)中最高電壓等級電力線路的額定電壓,以千伏計(jì)。1981年,建成平頂山-武漢,我國第一條500kV交流輸電線路。(4)電力系統(tǒng)電能質(zhì)量要求高,對電壓、頻率、波形都有嚴(yán)格的國家標(biāo)準(zhǔn)。如上所述,電能質(zhì)量包括電壓質(zhì)量、頻率質(zhì)量和波形質(zhì)量三個(gè)方面。優(yōu)點(diǎn)在于供電可靠性和電壓質(zhì)量高,缺點(diǎn)是不夠經(jīng)濟(jì)。,l0kV側(cè)出線共計(jì)14回,其中2回為站用變出線,無電源進(jìn)線,為電纜出線,每回負(fù)荷1600kVA,最大負(fù)荷利用小時(shí)數(shù)為5000h以上,其中一、二類負(fù)占總最大負(fù)荷的50%。(3)負(fù)荷的大小和重要性,一級負(fù)荷必須設(shè)兩個(gè)獨(dú)立電源供電;二級負(fù)荷一般也設(shè)兩個(gè)獨(dú)立電源供電;三級負(fù)荷一般只設(shè)一個(gè)電源供電。但接線過于簡單,可能又不能滿足運(yùn)行方式的需要,而且也會給運(yùn)行造成不便或造成不必要的停電。②對地區(qū)性孤立的一次變電站或大型專用變電站,在設(shè)計(jì)時(shí)應(yīng)考慮裝設(shè)三