【正文】
wer supply mode, the entire face in HV power supply, low pressure parts. Choice of the choice of equipment, cables, transformers, switch setting and the short circuit current calculation, to form the full face of the power supply system.Establishment of low power supply system in fully mechanized caving task is, according to the equipment requirements, the establishment of meeting the requirements of supporting equipment of power supply system. This article requires calculation of power supply including, choice of selection of cables, transformers, high voltage switch setting, select, twophase short circuit current calculation. In the design, fully taking into account the supply economy, practicality, and main power supply circuit to achieve doubleloop dual supply, ensuring the supply of intrinsically safe.This article through 2105 of low fully mechanized coal caving face design of power supply, with a real face as design carrier, accelerate the speed of face equipment and power supply. For the end of the mine construction and digital mine construction and lay a good foundation.供電實行雙回路供電,當(dāng)其中一回路因不可控原因發(fā)生故障,另一回路能馬上投入工作,能承載全部負荷。選擇電纜、供電設(shè)備時,必須全面滿足可靠性、選擇性、靈敏性和速動性的要求,當(dāng)同時滿足有困難時,可根據(jù)具體情況,予以調(diào)解,但不能降低對系統(tǒng)穩(wěn)定性的要求。生產(chǎn)格局為一井、一面、一條運輸線、日產(chǎn)萬噸、生產(chǎn)人員一千的集約高效生產(chǎn)模式。二水平共有2223四個采區(qū),20采區(qū)已結(jié)采,2223采區(qū)大巷均已施工完畢。井下有9個6KV變電所。井下各級變電所、主排水泵房,均采用雙回路電源供電,運行方式均采用分列運行方式供電。實現(xiàn)在井下千兆工業(yè)以太環(huán)網(wǎng),實現(xiàn)數(shù)據(jù)、視頻、音頻三網(wǎng)合一的全礦綜合自動化平臺。 21采區(qū)2105工作面基本概況 2105工作面巷道布置情況該工作面為低位放頂煤一次采全高綜采工作面,切眼長度190m(中—中),可采長度共1620m,可采儲量260萬噸。煤質(zhì)變化不大,均為貧煤, ?!?0176?!?0176。H=、270176。根據(jù)2105運巷掘進涌水情況及2303工作面涌水情況分析,預(yù)計2105工作面回采時最大涌水量為160m3/h,正常涌水量為80m3/h。主要配套設(shè)備如下:采煤機MGTY250/600 1臺 太原礦山機器集團公司生產(chǎn)刮板輸送機SGZ830/800 2部 西北奔牛轉(zhuǎn)載機SZZ960/250 1部 西北奔牛破碎機PLM2200 1臺 西北奔牛自移式皮帶機尾DY1200 1套 西北奔牛液壓支架 ZFS6000/17/33 119組 局機廠 排頭尾架 ZT6500/乳化液泵站BRW400/ 3臺(三泵一箱) 南京六合噴霧泵BPW315/10 1臺 南京六合 工作面設(shè)備安裝項目 支架切眼內(nèi)由南至北依次安裝ZT6500/,ZFS6000/17/33型中間架119組,ZT6500/;轉(zhuǎn)載機與排頭第一架之間增設(shè)一組副架(臨時支護頂板),第一組中間架中線距中運巷中線6400mm,支架每隔10架安裝一臺語音報警裝置。 皮帶機頭設(shè)備布置一部皮帶機頭安裝二臺KBSGZY1250/6/,四臺QJR400/1140型軟啟動開關(guān)供皮帶機使用,每臺電機均形成雙回路供電;二臺KBSGZY630/6/,作為排水、絞車、信號照明等電源;二臺ZBZ10型照明信號綜合保護,作為信號、照明電源;一臺QBZ80N開關(guān),作為漲緊絞車開關(guān);一部機尾前10米處安設(shè)一處過人橋。轉(zhuǎn)載機落地段與破碎機入口處安設(shè)一座過人橋;行人跨越轉(zhuǎn)載機機尾到排頭架處安設(shè)一座過人橋;破碎機出口段處安設(shè)一座過人橋。由西向東設(shè)備安裝順序為:3節(jié)備用車盤(備用轉(zhuǎn)載電機及減速機各1臺;大溜電機及減速機各1臺;破碎機錘頭軸組1件)———2臺備用MD15530*7離心泵——1臺采煤機二次負壓降塵泵——1臺負壓泵配套液箱——1臺支架噴霧泵——3臺乳化液泵(BRW400/)——1臺GX400供液箱——1臺ZJT1400/1140工變頻乳化液自動控制開關(guān)——4臺組合開關(guān)(HT6L400/1140)——4臺KBSGZY1600移變——消防器材——3輛電纜車,共26節(jié)車盤。開關(guān)整定牌和完好牌、責(zé)任牌齊全有效。7) 各電氣設(shè)備間的聯(lián)機必須排列整齊。11) 移變、電氣列車、油脂存放點等處必須安設(shè)至少2個合格的滅火器、。15) 工作面必須安設(shè)語音信號報警裝置及工作面刮板輸送機必須裝設(shè)能發(fā)出停止和起動的語音通訊系統(tǒng),發(fā)出信號的間距不得超過15m;工作面必須安設(shè)照明,間距不大于15m,皮帶機頭必須安設(shè)皮帶保護裝置,皮帶各類保護齊全有效。工具房及運巷繞道開關(guān)共計7臺:4臺BKD400中斷開關(guān)(運巷兩回,風(fēng)巷兩回)、1臺QBZ80N(調(diào)度絞車)、1臺ZJT1400/1140(自動配液工頻開關(guān))、1臺BZX4綜保(監(jiān)測監(jiān)控用)。4.2105工作面負荷統(tǒng)計工作面負荷統(tǒng)計計算見附表一,統(tǒng)計結(jié)果:1140V設(shè)備裝機功率ΣP=5130KW;660V系統(tǒng)設(shè)備裝機功率ΣP=;。A; VN,T=變壓器高壓側(cè)額定電壓,KV;移動變電站額定電流為IN,T1===154A根據(jù)生產(chǎn)實際,從表中選KBG250型隔爆真空配電箱,或額定電流大于250A的高壓配電箱。A; VN,T=變壓器高壓側(cè)額定電壓,KV;移動變電站額定電流為IN,T1===120A根據(jù)生產(chǎn)實際,從表中選KBG250型隔爆真空配電箱,或額定電流大于250A的高壓配電箱。A; VN,T=變壓器高壓側(cè)額定電壓,KV;移動變電站額定電流為IN,T1===60A根據(jù)生產(chǎn)實際,從表中選KBG250型隔爆真空配電箱,或額定電流大于250A的高壓配電箱。額定電流應(yīng)大于所帶變壓器總的最大長時工作電流。 高壓三回路變壓器選擇變壓器的計算容量為ST===900KVA式中ΣpN用電設(shè)備額定功率之和,即ΣpN=2315=630KW;Kde=需用系數(shù),即Kde=+=+=1;=容量最大電動機的額定功率;cosφWm=變壓器負載的加權(quán)平均功率因數(shù),查表得cosφWm=;查表選擇KBSGZY1250/6型隔爆移動變電站2臺,其額定容量=1250KVA,額定電壓為6KV/。故取MYPTJ350mm2截面的電纜。6KV(二)回路負荷:后溜電機2400KW、2乳化泵250KW、離心泵160KW;轉(zhuǎn)載機250KW、破碎機200KW、3乳化液泵250KW;總計為1910KW,負荷率按照60%計算,COSφ=6KV(二)回路額定電流為:Ig= Kt同時系數(shù)取1;Si視在功率;Ig=;查表MYPTJ350mm2截面電纜的載流量為200A。(三)回路高壓電纜選型6KV(三)回路按電纜載流量選擇校驗6KV(三)回路:供電距離起始點21采區(qū)變電所,終點為2105運巷電氣列車,總長度為1200 m。故選用MYPTJ350mm22000m為其供電。: △U=Ue5%=300V R= =查表得MYPTJ350mm2電纜R=,符合電壓降要求。故選用MCPTB3120mm2410m電纜為其供電。前溜機尾高速與其相同,不再計算。前溜機尾低速與其相同,不再計算。 水泵電纜的選擇總長度L=(轉(zhuǎn)載機長度50m+拖拉電纜100m+列車段50m)(電纜伸縮系數(shù))=210m,電纜長度取210m。皮帶電機負荷630KW,負荷率按照60%計算,COSφ=;Ig= 225A; 查表MCP395mm2截面的電纜載流量260A225A △U=Ue5%=57V R= = 查表得MCP395mm2電纜R=, 符合電壓降要求。電纜型號:50+125;6KV(二)回路:起始端21采區(qū)變電所,終點端2105電氣列車距離2000米。660V低壓電纜風(fēng)巷雙回路排水21800米;(70mm2)運巷雙回路排水21600米;(70mm2)其他電纜距離比較短,在此不一一列出,具體數(shù)量見附表。短路回路阻抗計算1)系統(tǒng)電抗。已知這段電纜長為2km、變壓器變比Ksc=6300/1200=,求得折合到低壓側(cè)的電阻R及電抗X分別為Rg===Xg===3)變壓器的阻抗。 短路保護。鋼絞線將高壓連接器與接地極相連接地移動變電站的高壓部分也利用鋼絞線將高壓開關(guān)與接地極相連接連接接地。 工作面接地保護設(shè)計低壓開關(guān)均使用鋼絞線將開關(guān)與接地極相連接地。井下接地保護系統(tǒng)由主接地極、局部接地極、接地母線、輔助接地母線、接地導(dǎo)線和連接導(dǎo)線等組成。有幾個水平的礦井,每個水平的總接地網(wǎng)都要與主接地極連接。連接動力鎧裝電纜的每個接線盒以及高壓電纜連接裝置。井下各機電硐室、配電點、采區(qū)變電所內(nèi)與局部接地極、電氣設(shè)備外殼、電纜的接地部分連接的母線稱為輔助接地母線。從局部接地極引出的導(dǎo)線稱接地導(dǎo)線。采掘工作面的移動機械以及不便裝設(shè)固定接地極的設(shè)備,它們的外殼利用6芯或4芯橡套軟電纜中的接地芯線來接地。要求從任意一個局部接地裝置處所測得接地系統(tǒng)總接地電阻不得超過2Ω。在工作面安裝一套語音電話系統(tǒng),間距1臺/15米。高壓連接裝置采用硬鏈接,型號為BHG1400A/100。電纜敷設(shè)平直,同鉤電纜弧垂一致。電纜拖拉段的電纜采用單軌梁懸空吊掛方式進行懸掛。小型電器必須上牌上版。懸掛高度、相對位置要統(tǒng)一。安裝過程中,要有動態(tài)安裝記錄、驗收記錄,進行大范圍高壓電纜安裝過程中,電力科要進行驗收,確保一次到位。因此工作面供電設(shè)計是礦山煤炭生產(chǎn)的重要內(nèi)容之一。致 謝兩年的大學(xué)學(xué)業(yè)即將結(jié)束,在此我想對我的母校、我的家人、我的老師、同學(xué)們表達我由衷的謝意。參考文獻(1) :煤炭工業(yè)出版社,(2) . 北京:煤炭工業(yè)出版社,(3) :煤炭工業(yè)出版社,