freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

臨時用電設(shè)計專項施工方案培訓(xùn)資料-預(yù)覽頁

2025-05-27 01:59 上一頁面

下一頁面
 

【正文】 = ,tgφ = Pjs = KxPe = = Qjs = Pjstgφ = = (38)干粉砂漿攪拌機組Kx = ,Cosφ = ,tgφ = Pjs = KxPe = = Qjs = Pjstgφ = = (39)插入式振動器_ZX50C組Kx = ,Cosφ = ,tgφ = Pjs = KxPe = = Qjs = Pjstgφ = = (40)振搗棒組Kx = ,Cosφ = ,tgφ = Pjs = KxPe = = Qjs = Pjstgφ = = (41)交流電焊機_BX31201組Kx = ,Cosφ = ,tgφ = 將Jc = 40%統(tǒng)一換算到Jc = 100%的額定容量Pe = n(Jc/Jc1)1/2Pn = 1()1/2 = Pjs = KxPe = = Qjs = Pjstgφ = = (42)混凝土磨光機 型號:TZL3SM80組Kx = ,Cosφ = ,tgφ = Pjs = KxPe = = Qjs = Pjstgφ = = (43)總的計算負荷計算,干線同期系數(shù)取 Kx = 總的有功功率Pjs = KxΣPjs = (+++++++++++++++++++++++++++++++++++++++++) = 總的無功功率Qjs =KxΣQjs = (+++++++++++++++++++++++++++++++++++++++++) = 總的視在功率Sjs = (Pjs2+Qjs2)1/2 = (+)1/2 = 總的計算電流計算Ijs = Sjs/(Ue) = () = 選擇變壓器根據(jù)計算的總的視在功率選擇SL7400/10型三相電力變壓器,≥(增容系數(shù))能夠滿足使用要求。干1(1樓)線路上導(dǎo)線截面及分配箱、開關(guān)箱內(nèi)電氣設(shè)備選擇在選擇前應(yīng)對照平面圖和系統(tǒng)圖先由用電設(shè)備至開關(guān)箱計算,再由開關(guān)箱至分配箱計算,選擇導(dǎo)線及開關(guān)設(shè)備。(1)雙籠電梯開關(guān)箱至雙籠電梯導(dǎo)線截面及開關(guān)箱內(nèi)電氣設(shè)備選擇i)計算電流Kx 取 ,Cosφ = Ijs = KxPe/(UeCosφ) = () = ii)選擇導(dǎo)線按允許電壓降:S = KxΣ(PL)/C△U = () = 選擇BX316+26,空氣明敷時其安全載流量為110A。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)開關(guān)為DZ520/330,其脫扣器整定電流值為Ir = 16A。漏電保護器為ZBM163/10。(5)交流電焊機_BX31201開關(guān)箱至交流電焊機_BX31201導(dǎo)線截面及開關(guān)箱內(nèi)電氣設(shè)備選擇i)計算電流Kx 取 ,Cosφ = Ijs = KxPe/(UeCosφ) = () = ii)選擇導(dǎo)線按允許電壓降:S = KxΣ(PL)/C△U = () = 選擇BX31+26,空氣明敷時其安全載流量為21A。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)開關(guān)為DZ520/330,其脫扣器整定電流值為Ir = 16A。漏電保護器為DZ10L100/3。(9)分2(樓層)至第1組電機的開關(guān)箱的導(dǎo)線截面及分配箱內(nèi)開關(guān)的選擇i)Ijs = ii)選擇導(dǎo)線選擇VV34+2,空氣明敷時其安全載流量為30A。室外架空銅芯電纜線按機械強度的最小截面為10mm2,滿足要求。iii)選擇電氣設(shè)備選擇分配箱進線開關(guān)為DZ10250/3,其脫扣器整定電流值為Ir = 200A。iii)選擇電氣設(shè)備選擇分配箱進線開關(guān)為DZ520/330,其脫扣器整定電流值為Ir = 16A。iii)選擇電氣設(shè)備選擇分配箱進線開關(guān)為DZ10250/3,其脫扣器整定電流值為Ir = 200A。ii)選擇出線開關(guān)干1(1樓)出線開關(guān)選擇DZ10250/3,其脫扣器整定電流值為Ir = 200A。分6(升降機)至開關(guān)箱,開關(guān)箱至用電設(shè)備采用銅芯聚氯乙烯絕緣電纜線空氣明敷。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)開關(guān)為DZ520/330,其脫扣器整定電流值為Ir = 16A。漏電保護器為ZBM1100/80。(4)干粉砂漿攪拌機開關(guān)箱至干粉砂漿攪拌機導(dǎo)線截面及開關(guān)箱內(nèi)電氣設(shè)備選擇i)計算電流Kx 取 ,Cosφ = Ijs = KxPe/(UeCosφ) = () = ii)選擇導(dǎo)線按允許電壓降:S = KxΣ(PL)/C△U = () = 選擇BX31+26,空氣明敷時其安全載流量為21A。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)開關(guān)為DZ520/330,其脫扣器整定電流值為Ir = 16A。漏電保護器為ZBM163/10。(8)混凝土磨光機 型號:TZL3SM80開關(guān)箱至混凝土磨光機 型號:TZL3SM80導(dǎo)線截面及開關(guān)箱內(nèi)電氣設(shè)備選擇i)計算電流Kx 取 ,Cosφ = Ijs = KxPe/(UeCosφ) = () = ii)選擇導(dǎo)線按允許電壓降:S = KxΣ(PL)/C△U = () = 選擇BX31+16+11,空氣明敷時其安全載流量為21A。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)開關(guān)為DZ10250/3,其脫扣器整定電流值為Ir = 200A。iii)選擇電氣設(shè)備選擇分配箱內(nèi)開關(guān)為DZ520/330,其脫扣器整定電流值為Ir = 16A。(12)分6(升降機)至第1組電機的開關(guān)箱的導(dǎo)線截面及分配箱內(nèi)開關(guān)的選擇i)Ijs = ii)選擇導(dǎo)線選擇VV335+216,空氣明敷時其安全載流量為115A。室外架空銅芯電纜線按機械強度的最小截面為10mm2,滿足要求。iii)選擇電氣設(shè)備選擇分配箱內(nèi)開關(guān)為DZ10250/3,其脫扣器整定電流值為Ir = 200A。漏電保護器為RMM163/12。漏電保護器為ZBM1100/80。漏電保護器為DZ10L100/3。漏電保護器為ZBM163/10。漏電保護器為ZBM1100/80。干3(4樓)線路上導(dǎo)線截面及分配箱、開關(guān)箱內(nèi)電氣設(shè)備選擇在選擇前應(yīng)對照平面圖和系統(tǒng)圖先由用電設(shè)備至開關(guān)箱計算,再由開關(guān)箱至分配箱計算,選擇導(dǎo)線及開關(guān)設(shè)備。(1)雙籠電梯開關(guān)箱至雙籠電梯導(dǎo)線截面及開關(guān)箱內(nèi)電氣設(shè)備選擇i)計算電流Kx 取 ,Cosφ = Ijs = KxPe/(UeCosφ) = () = ii)選擇導(dǎo)線按允許電壓降:S = KxΣ(PL)/C△U = () = 選擇BX316+26,空氣明敷時其安全載流量為110A。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)開關(guān)為DZ520/330,其脫扣器整定電流值為Ir = 16A。漏電保護器為ZBM163/10。(5)交流電焊機_BX31201開關(guān)箱至交流電焊機_BX31201導(dǎo)線截面及開關(guān)箱內(nèi)電氣設(shè)備選擇i)計算電流Kx 取 ,Cosφ = Ijs = KxPe/(UeCosφ) = () = ii)選擇導(dǎo)線按允許電壓降:S = KxΣ(PL)/C△U = () = 選擇BX31+26,空氣明敷時其安全載流量為21A。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)開關(guān)為DZ520/330,其脫扣器整定電流值為Ir = 16A。漏電保護器為DZ15L63/3。(9)分10(4樓層)至第1組電機的開關(guān)箱的導(dǎo)線截面及分配箱內(nèi)開關(guān)的選擇i)Ijs = ii)選擇導(dǎo)線選擇VV34+2,空氣明敷時其安全載流量為30A。室外架空銅芯導(dǎo)線按機械強度的最小截面為10mm2,滿足要求。iii)選擇電氣設(shè)備選擇分配箱進線開關(guān)為DZ10250/3,其脫扣器整定電流值為Ir = 200A。iii)選擇電氣設(shè)備選擇分配箱進線開關(guān)為DZ520/330,其脫扣器整定電流值為Ir = 16A。iii)選擇電氣設(shè)備選擇分配箱進線開關(guān)為DZ15100/3,其脫扣器整定電流值為Ir = 80A。ii)選擇出線開關(guān)干3(4樓)出線開關(guān)選擇DZ10250/3,其脫扣器整定電流值為Ir = 200A。分14(7升降機)至開關(guān)箱,開關(guān)箱至用電設(shè)備采用銅芯聚氯乙烯絕緣電纜線空氣明敷。(2)振搗棒開關(guān)箱至振搗棒導(dǎo)線截面及開關(guān)箱內(nèi)電氣設(shè)備選擇i)計算電流Kx 取 ,Cosφ = Ijs = KxPe/(UeCosφ) = () = ii)選擇導(dǎo)線按允許電壓降:S = KxΣ(PL)/C△U = () = 選擇BX31+26,空氣明敷時其安全載流量為21A。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)開關(guān)為DZ520/330,其脫扣器整定電流值為Ir = 16A。漏電保護器為ZBM163/10。(6)雙籠電梯開關(guān)箱至雙籠電梯導(dǎo)線截面及開關(guān)箱內(nèi)電氣設(shè)備選擇i)計算電流Kx 取 ,Cosφ = Ijs = KxPe/(UeCosφ) = () = ii)選擇導(dǎo)線按允許電壓降:S = KxΣ(PL)/C△U = () = 選擇BX316+26,空氣明敷時其安全載流量為110A。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)開關(guān)為DZ520/330,其脫扣器整定電流值為Ir = 16A。iii)選擇電氣設(shè)備選擇分配箱內(nèi)開關(guān)為DZ10250/3,其脫扣器整定電流值為Ir = 200A。(10)分14(7升降機)至第1組電機的開關(guān)箱的導(dǎo)線截面及分配箱內(nèi)開關(guān)的選擇i)Ijs = ii)選擇導(dǎo)線選擇VV335+216,空氣明敷時其安全載流量為115A。室外架空銅芯電纜線按機械強度的最小截面為10mm2,滿足要求。室外架空銅芯電纜線按機械強度的最小截面為10mm2,滿足要求。室外架空銅芯電纜線按機械強度的最小截面為10mm2,滿足要求。室外架空銅芯電纜線按機械強度的最小截面為10mm2,滿足要求。分16(8樓升降機)至開關(guān)箱,開關(guān)箱至用電設(shè)備采用銅芯聚氯乙烯絕緣電纜線空氣明敷。漏電保護器為ZBM1100/16。(3)鋼筋彎曲機_GW40開關(guān)箱至鋼筋彎曲機_GW40導(dǎo)線截面及開關(guān)箱內(nèi)電氣設(shè)備選擇i)計算電流Kx 取 ,Cosφ = Ijs = KxPe/(UeCosφ) = () = ii)選擇導(dǎo)線按允許電壓降:S = KxΣ(PL)/C△U = () = 選擇BX31+26,空氣明敷時其安全載流量為21A。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)開關(guān)為DZ520/330,其脫扣器整定電流值為Ir = 16A。漏電保護器為ZBM163/10。(7)消防泵開關(guān)箱至消防泵導(dǎo)線截面及開關(guān)箱內(nèi)電氣設(shè)備選擇i)計算電流Kx 取 ,Cosφ = Ijs = KxPe/(UeCosφ) = () = ii)選擇導(dǎo)線按允許電壓降:S = KxΣ(PL)/C△U = () = 選擇BX310+26,空氣明敷時其安全載流量為85A。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)開關(guān)為DZ520/330,其脫扣器整定電流值為Ir = 16A。漏電保護器為ZBM163/10。(11)交流電焊機_BX31201開關(guān)箱至交流電焊機_BX31201導(dǎo)線截面及開關(guān)箱內(nèi)電氣設(shè)備選擇i)計算電流Kx 取 ,Cosφ = Ijs = KxPe/(UeCosφ) = () = ii)選擇導(dǎo)線按允許電壓降:S = KxΣ(PL)/C△U = () = 選擇BX31+26,空氣明敷時其安全載流量為21A。iii)選擇電氣設(shè)備選擇開關(guān)箱內(nèi)開關(guān)為DZ520/330,其脫扣器整定電流值為Ir = 16A。iii)選擇電氣設(shè)備選擇分配箱內(nèi)開關(guān)為DZ15100/3,其脫扣器整定電流值為Ir = 80A。(15)分17(8樓層)至第1組電機的開關(guān)箱的導(dǎo)線截面及分配箱內(nèi)開關(guān)的選擇i)Ijs = ii)選擇導(dǎo)線選擇VV34+2,空氣明敷時其安全載流量為30A。室外架空銅芯電纜線按機械強度的最小截面為10mm2,滿足要求。室外架空銅芯電纜線按機械強度的最小截面為10mm2,滿足要求。室外架空銅芯電纜線按機械強度的最小截面為10mm2,滿足要求。室外架空銅芯電纜線按機械強度的最小截面為10mm2,滿足要求。(3)根據(jù)施工現(xiàn)場用電設(shè)備布置情況,總線采用電纜線空氣明敷,干1(3樓)采用電纜線空氣明敷,干2(5樓)采用電纜線空氣明敷,干3(6樓)采用電纜線空氣明敷,干4(9樓)采用電纜線空氣明敷,干5(綜合樓)采用電纜線空氣明敷,分1(3塔吊)采用電纜線空氣明敷,分2(3樓升降機)采用電纜線空氣明敷,分3(3樓層)采用電纜線空氣明敷,分4(5塔吊)采用電纜線空氣明敷,分5(5樓升降機)采用電纜線空氣明敷,分6(5樓樓層)采用電纜線空氣明敷,分7(圓盤鋸)采用電纜線空氣明敷,分8(高壓泵)采用電纜線空氣明敷,分9(6塔吊)采用電纜線空氣明敷,分10(6升降機)采用電纜線空氣明敷,分11(6樓層)采用電纜線空氣明敷,分12(鋼筋制作)采用電纜線空氣明敷,分13(9塔吊)采用電纜線空氣明敷,分14(9升降機)采用電纜線空氣明敷,分15(9樓層)采用電纜線空氣明敷,分16(鋼筋制作)采用電纜線空氣明敷,分17(綜合樓)采用電纜線空氣明敷,布置位置及線
點擊復(fù)制文檔內(nèi)容
公司管理相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1