freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

空調(diào)說明書---辦公樓空調(diào)工程設(shè)計(jì)-全文預(yù)覽

2025-01-04 00:39 上一頁面

下一頁面
  

【正文】 handling unit. Cold and hot and cold water source unit using lithium bromide. The thermal insulation material of water pipe and air duct are foam plastics and centrifugal glass wool tower selction of circular pressrue use of expansion tank ways and lay it on the top of the building. Measures of noise elimination, damp, fire prevention and smoke extraction is considered during the design. The whole system process to achieve high efficiency, energy saving, environmental protection purposes in the design. Strictly abide by the norms of airconditioning, reference information, the system in all aspects of an integrated consideration, thus providing a practical airconditioning system design Key Words: air conditioning,primary air fancoil system,all air system,fresh air 河南科技大學(xué)畢業(yè)設(shè)計(jì) III 目 錄 前 言 .................................................... 1 第 1 章 工程概況 ......................................... 2 167。系統(tǒng)定壓采用膨脹水箱定壓方式,置于大樓樓頂。因杭州市無城市熱力管網(wǎng),故系統(tǒng)冷熱源采用直燃式溴化鋰?yán)錈崴畽C(jī)組,采用了閉式水平 異程,豎直同程 兩管制定流量水系統(tǒng)。河南科技大學(xué)畢業(yè)設(shè)計(jì) I 杭州市人民政府辦公樓空調(diào)工程設(shè)計(jì) 摘 要 本設(shè)計(jì)為杭州市人民政府辦公大樓空調(diào)工程設(shè)計(jì),大樓共十一層 , 總建筑面積 ㎡,包括一樓大廳,辦公室 ,娛樂室 ,結(jié)算室 ,調(diào)解室 ,信訪室等功能間。新風(fēng)從墻洞引入,再由新風(fēng)機(jī)組集中處理供應(yīng)。 冷卻塔選用圓形逆式冷卻塔,置于大樓樓頂。 整個(gè)系統(tǒng)在設(shè)計(jì)過程中,以達(dá)到高效、節(jié)能、環(huán)保的目的。 屋頂?shù)倪x型和校核 ............................... 3 167。 房間散濕量 .................................... 12 167。 水系統(tǒng)方案確定 ................................ 19 167。 空調(diào)系統(tǒng)的運(yùn)行調(diào)節(jié) ........................... 28 第 4 章 空調(diào)設(shè)備的選擇 .................................. 30 167。 冷熱源機(jī)組選型 ................................ 34 第 5 章 房間氣流組織的確定和計(jì)算 ....................... 36 167。 風(fēng)口型式的確定 ................................ 37 167。 冷凝水管的設(shè)計(jì) ................................ 53 167。 冷卻塔的選擇 .................................. 60 167。 空調(diào)系統(tǒng)的減振 ................................ 69 第 9 章 確定管道的保溫、防腐的措施 ...................... 70 167。于是空調(diào)技術(shù)的革新與發(fā)展,對(duì) 世界 經(jīng)濟(jì) 以及 普通民生均產(chǎn)生積極而深遠(yuǎn)的影響。 在現(xiàn)代的辦公大樓中,通過采用舒適性空氣調(diào)節(jié)系統(tǒng),保證了辦公人員在工作生產(chǎn)時(shí)的舒適性感覺。 河南科技大學(xué)畢業(yè)設(shè)計(jì) 2 第 1章 工程概況 167。 167。 10′ 海拔 室外計(jì)算干球溫度: 冬季空調(diào)溫度: 1℃ 夏季空調(diào)溫度: ℃ 夏季空調(diào)日平均溫度: ℃ 室外計(jì)算濕球溫度: 夏季空調(diào)濕球 溫度: ℃ 相對(duì)濕度: 80% 冬季空調(diào)室外相對(duì)濕度: 77% 大氣壓力: 冬季: 河南科技大學(xué)畢業(yè)設(shè)計(jì) 3 夏季: kPa 室外風(fēng)速 (m/s)。 屋頂?shù)倪x型和校核 167。 167。C,屋頂取 。 1 外墻墻體的選型 外墻的構(gòu)造如圖 12所示。 外墻墻體的校核 最小傳熱熱阻: )422( tta yy wnm in. ?? ???? ? )(OR W/(㎡ .K) 式中: tn—— 冬季室內(nèi)計(jì)算溫度, ℃ ; tw—— 圍護(hù)結(jié)構(gòu)冬季室外計(jì)算溫度 ,℃; n? —— 圍護(hù)結(jié)構(gòu)內(nèi)表面換熱系數(shù), W/(m178。 1. 1111 ?????? kaRaR wjnO W/(㎡ .K)= (㎡ .k/w) 由此可知 R o min.?R ,故所選外墻滿足要求 . 河南科技大學(xué)畢業(yè)設(shè)計(jì) 5 第 2章 冷、熱、濕負(fù)荷的計(jì)算 167。 2. 內(nèi)墻 ,樓板等室內(nèi)傳熱維護(hù)結(jié)構(gòu)形成的瞬 時(shí)冷負(fù)荷 當(dāng)空調(diào)房間的溫度與相鄰非空調(diào)房間的溫度大于 3℃時(shí) ,要考慮內(nèi)維護(hù)結(jié)構(gòu)間的溫差傳熱對(duì)空調(diào)房間形成的瞬時(shí)冷負(fù)荷 ,可按如下傳熱公式計(jì)算: )( .)(c Rmoii tttAKQ ????? ( ) 式中: Ai—— 內(nèi)圍護(hù)結(jié)構(gòu)的傳熱面積, m178。 在室內(nèi)外溫差的作用下 , 玻璃窗瞬時(shí)傳熱形成的冷負(fù)荷可按下式計(jì)算 : )( )()( RcWWc ttAKQ ?? ?? ( ) 式中: )(?CQ —— 外玻璃窗的逐時(shí)冷負(fù)荷, W; KW—— 玻璃的傳熱系數(shù), W /( m178。 透過玻璃窗的日射得熱引起的冷負(fù)荷 透過玻璃窗進(jìn)入室內(nèi)的日射得熱形成的逐時(shí)冷負(fù)荷按下式計(jì)算 : LQjiswaC CDCCACQ m a x)( ?? ( ) 式中 : AW—— 玻璃窗的面積 , ㎡; —— 玻璃窗的綜合遮擋系數(shù) =CS CLQ () 熒光燈 : )(?CQ =1000 CLQ () 式中: )(?CQ —— 燈具散熱形成的冷負(fù)荷, W; N—— 照明燈具所需功率, KW; n1—— 鎮(zhèn)流器消耗功率系數(shù),當(dāng)明裝熒光燈的鎮(zhèn)流器裝在空調(diào)房間內(nèi)時(shí),取 n1= ;當(dāng)暗裝熒光燈鎮(zhèn)流器裝設(shè)在頂棚內(nèi)時(shí),可取 n1= ;本設(shè)計(jì) 取 n1= ; n2—— 燈罩隔熱系數(shù),當(dāng)熒光燈上部穿有小孔(下部為玻璃板),可利用自然通風(fēng)散熱與 頂棚內(nèi)時(shí),取 n2= ~ ;而熒光燈罩無通風(fēng)孔時(shí) ,取 n2= ~ ;本設(shè)計(jì) 取 n2= ; CLQ—— 照明散熱冷負(fù)荷系數(shù)。 表 210 大樓冷負(fù)荷匯總 時(shí)間 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 大廳 8826 9024 9200 5637 一層 66440 68514 70025 73504 77604 80370 75792 73421 55191 二層 79738 82474 84514 89838 96399 100931 94193 90798 66876 三 ~十層 86798 90271 92914 98151 103997 107835 100572 96828 71062 十一層 92752 96194 99080 104862 111448 116251 108584 105925 80688 根據(jù)匯總情況可得 ,負(fù)荷最大值出現(xiàn)在 15:00,因此選此時(shí)作為計(jì)算依據(jù) ,根據(jù)大樓總負(fù)荷 1169584w,總面積 ㎡求得大樓冷指標(biāo) : q= 93711 6954 8 ??fQw/㎡ 167?!?); Rt —— 冬季室內(nèi)計(jì)算溫度,℃ wot. —— 采暖室外計(jì)算溫度,℃; 河南科技大學(xué)畢業(yè)設(shè)計(jì) 11 ? —— 圍護(hù)結(jié)構(gòu)的溫差修正系數(shù), 二、朝向附加耗熱量: 朝向附加耗熱量是考慮建筑物受太陽照射影響而對(duì)圍護(hù)結(jié)構(gòu)基本耗熱量的修正。在本設(shè)計(jì)中,由于建筑物一 ,二層的層高為 米。 由于空調(diào)建筑室內(nèi)通常保持正壓,因而在一般情況下,不計(jì)算門窗縫隙滲入室內(nèi)的冷空氣和由門,孔洞等侵入室內(nèi)的冷空氣引起的耗熱量 , 以 101 室為例計(jì)算房間的熱負(fù)荷 ,如表 212: 表 212 101 房間熱負(fù)荷計(jì)算 房間 方向 面積 k t1 t2 t1t2 a Q 風(fēng)力 附加 修正值 修正后的熱量 101 北外墻 20 4 24 1 884 0 北外窗 20 4 24 1 398 0 河南科技大學(xué)畢業(yè)設(shè)計(jì) 12 西外墻 20 4 24 1 487 0 西外窗 20 4 24 1 199 0 其它房間熱負(fù)荷見附表二 同樣的方法,依據(jù)大樓總熱負(fù)荷以及總面積得到辦公大樓熱指標(biāo)為㎡。 新風(fēng)負(fù)荷 最小新風(fēng)量的確定: 1. 新風(fēng) 量多少的矛盾問題:從 改善室內(nèi)空氣品質(zhì)角度,新風(fēng)量應(yīng)多,但耗能,從節(jié)能角度,新風(fēng)量宜少。如果計(jì)算新風(fēng)量不足送風(fēng)量的 10%,則取送風(fēng)量的 10%。 b、本辦公樓屬于辦公建筑物,對(duì)溫濕度的控制要求不嚴(yán)格。 167。 方案比較 全空氣系統(tǒng)與空氣 水系統(tǒng)是現(xiàn)在普遍運(yùn)用的兩種方式 ,現(xiàn)將兩種方案的優(yōu)缺點(diǎn)總結(jié)歸納見表 32: 表 32 全空氣系統(tǒng)與空氣-水系統(tǒng) 方案比較表 比較項(xiàng)目 全空氣系統(tǒng) 空氣 -水系統(tǒng) 設(shè)備布置與機(jī)房 1. 空調(diào)與制冷設(shè)備可以集中布置在機(jī)房 2. 機(jī)房面積較大層高較高 3. 有時(shí)可以布置在屋頂或安設(shè)在車間柱間平臺(tái)上 1. 只需要新風(fēng)空調(diào)機(jī)房、機(jī)房面積小 2. 風(fēng)機(jī)盤管可以設(shè)在空調(diào)機(jī)房?jī)?nèi) 3. 分散布置、敷設(shè)各種管線較麻煩 風(fēng)管系統(tǒng) 1. 空調(diào)送回風(fēng)管系統(tǒng)復(fù)雜、布置困難 2. 支風(fēng)管和風(fēng)口較多時(shí)不易均衡調(diào)節(jié)風(fēng)量 1. 放室內(nèi)時(shí)不接送、回風(fēng)管 2. 當(dāng)和新風(fēng)系統(tǒng)聯(lián)合使用時(shí),新風(fēng)管較小 續(xù)表 32 河南科技大學(xué)畢業(yè)設(shè)計(jì) 16 節(jié)能與經(jīng)濟(jì)性 1. 可以根據(jù)室外氣象參數(shù)的變化和室內(nèi)負(fù)荷變化實(shí)現(xiàn)全年多工況節(jié)能運(yùn)行調(diào)節(jié),充分利用室外新風(fēng)減少 與避免冷熱抵消,減少冷凍機(jī)運(yùn)行時(shí)間 2. 對(duì)熱濕負(fù)荷變化不一致或室內(nèi)參數(shù)不同的多房間不經(jīng)濟(jì) 3. 部分房間停止工作不需空調(diào)時(shí)整個(gè)空調(diào)系統(tǒng)仍需運(yùn)行不經(jīng)濟(jì) 1. 靈活性大、節(jié)能效果好,可根據(jù)各室負(fù)荷情況自我調(diào)節(jié) 2. 盤管冬夏兼用,內(nèi)避容易結(jié)垢,降低傳熱效率 3. 無法實(shí)現(xiàn)全年多工況節(jié)能運(yùn)行 使用壽命 使用壽命長(zhǎng) 使用壽命較長(zhǎng) 安裝 設(shè)備與風(fēng)管的安裝工作量大周期長(zhǎng) 安裝投產(chǎn)較快,介于集中式空調(diào)系統(tǒng)與單元式空調(diào)器之間 維護(hù)運(yùn)行 空調(diào)與制冷設(shè)備集中安設(shè)在機(jī)房便于管理和維護(hù) 布置分散維護(hù)管理不方便,水系統(tǒng)布置復(fù)雜、易漏水 溫濕 度控制 可以嚴(yán)格地控制室內(nèi)溫度和室內(nèi)相對(duì)濕度 對(duì)室內(nèi)溫度要求嚴(yán)格時(shí)難于滿足 空氣過濾與凈化 可以采用初中效和高效過濾器,滿足室內(nèi)空氣清潔度的不同要求,采用噴水室時(shí)水與空氣直接接觸易受染,須常換水 過濾性能差,室內(nèi)清潔度要求較高時(shí)難于滿足 消聲與隔振 可以有效地采取消防和隔振措施 必須采用低噪聲風(fēng)機(jī)才能保證室內(nèi)要求 風(fēng)管互相串通 空調(diào)房間之間有風(fēng)管連通,使各房間互相污染,當(dāng)發(fā)生火災(zāi)時(shí)會(huì)通過風(fēng)管迅速蔓延 各空調(diào)房間之間不會(huì)互相污染 河南科技大學(xué)畢業(yè)設(shè)計(jì) 17 空氣 水系統(tǒng)最為普遍
點(diǎn)擊復(fù)制文檔內(nèi)容
研究報(bào)告相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1