【正文】
器的開斷電流一般按兩相短路計(jì)算,若發(fā)電機(jī)出口的兩相短路或中性點(diǎn)直接接地系統(tǒng)中的單項(xiàng)或兩相接地短路較三相短路嚴(yán)重時(shí),應(yīng)按最嚴(yán)重的情況計(jì)算。 1 輸電線路的電容略去不計(jì); 1 用概率統(tǒng)計(jì)法制定短路電流運(yùn)算曲線。 本變電所 60出線為 14回,且均為重要負(fù)荷,應(yīng)主要側(cè)重于可靠性和靈活性。 兩種接線的比較如下: 圖 23 雙母線接線 文關(guān) 220kV 降壓變電所電氣部分初步設(shè)計(jì) 13 圖 24 雙母線帶旁路接線 a、雙母線接線: 雙母線接線的特點(diǎn)在 220kV側(cè)接線方式選擇論證中已詳細(xì)說明,此處不再綴述。 根據(jù)《 220500kV變電所設(shè)計(jì)技術(shù)規(guī)程》 SDJ2— 88規(guī)定, 220kV配電裝置 出線回?cái)?shù)在四回及以上時(shí),宜采用雙母線或其他接線。 ( 2)靈活性。 根據(jù)《電力工程設(shè)計(jì)手冊(cè)》的要求,主接線應(yīng)滿足可靠性、靈活性,并在此基礎(chǔ)上考慮 做到經(jīng)濟(jì)合理。 配電裝置復(fù)雜,運(yùn)行操作復(fù)雜。 用斷路器把母線分段后,對(duì)重要負(fù)責(zé)用戶可以從不同的母線段引出兩個(gè)回路,有兩個(gè)電源,具有供電可靠性。 ( 3)母聯(lián)斷路器故障,將造成配電裝置全停。 ( 6)、便于實(shí)驗(yàn)。 ( 4)運(yùn)行高度靈活。 兩種接線的比較如下: 沈陽(yáng)工程學(xué)院畢業(yè)設(shè)計(jì) 10 圖 21 雙母線接線 圖 22 單母線分段帶旁路母線接線 文關(guān) 220kV 降壓變電所電氣部分初步設(shè)計(jì) 11 a、雙母線接線 單斷路器的雙母線接線中,每個(gè)回路均通過一臺(tái)斷路器和兩組隔離開關(guān),連接到兩組母線上,電源和出線可均勻地分布在兩組母線上,普遍適用于 6~ 220kV 電壓等級(jí)的配電裝置中,此接線有以下幾個(gè)優(yōu)點(diǎn): ( 1)可以輪流檢修母線而不影響供電,只需將要檢修的那組母線上所連接的電源和線路通過兩組母線隔離開關(guān)的倒閘操作,全部切換到另一組母線上。 電氣主接線的選擇 主接線的預(yù)定方案 本變電所電壓等級(jí)為 220kV/60kV, 220kV側(cè)進(jìn)線為 2回; 60kV側(cè)出線為 12回。 主接線設(shè)計(jì)的基本要求 可靠性 1) 研究主接線可靠性應(yīng)注意的問題: a、 應(yīng)重視 國(guó)內(nèi)外長(zhǎng)期運(yùn)行實(shí)踐經(jīng)驗(yàn)及其可靠性的定性分析; b、 主接線的可靠性包括一次部分和二次部分在運(yùn)行中的可靠性的綜合; c、 主接線的可靠性在很大程度上取決于設(shè)備的可靠性程度,采用可靠性能高的電氣設(shè)備可以簡(jiǎn)化接線。 4) 考慮主變臺(tái)數(shù)對(duì)主接線的影響 變電所主變的容量和臺(tái)數(shù),對(duì)變電所主接線的選擇將產(chǎn)生直接的影響。 1) 變電所在電力系統(tǒng)中的地位和作用 變電所在電力系統(tǒng)中的地位和作用是決定主接線的主要因素,變電所是樞紐變電所、地區(qū)變電所、終端變電所、企業(yè)變電所還是分支變電所,由于他們?cè)陔娏ο到y(tǒng)中的地位和作用不同,對(duì)主接線的可靠性、靈活性、經(jīng)濟(jì)性的技術(shù)要求也不同。主接線的確定對(duì)變電所的安全、穩(wěn)定、靈活、經(jīng)濟(jì)運(yùn)行以及對(duì)電氣設(shè)備選擇、配電裝置布置、繼電保護(hù)擬定等都有著密切的關(guān)系。 容量的確定: P1=20220+10000+20220+5000=55000kw P2=20220+5000=25000kw Pmax1=P1*Kp*= Pmax2=P2*Kp*= S1=Pmax1/cosφ 1=S1=Pmax2/cosφ 2=21250/= S=(S1+S2)*=*= 總安裝容量為 根據(jù)以上計(jì)算可選擇兩臺(tái)型號(hào)為 SFPZ463000/220的有載調(diào)壓變壓器。電力系統(tǒng)采用的繞組連接方式只有 Y 和△,高、中、低三側(cè)繞組組合要根據(jù)工程具體情況確定。 (PZMAX 為綜 合最大負(fù)荷 ) (3)應(yīng)根據(jù)電力系統(tǒng) 5~ 10年的發(fā)展規(guī)劃進(jìn)行選擇。 (4)具有三種電壓的變電所,例如 220kV, 110kV, 35kV一般采用三繞組變壓器。當(dāng)裝設(shè)一組單相變壓器時(shí),應(yīng)考慮裝設(shè)備用相,當(dāng)主變超過一組,且各組容量滿足全所負(fù)荷的 75%時(shí),可不裝設(shè)備用相。對(duì)大型樞紐變電所,根據(jù)工程的具體情況,應(yīng)安裝 24臺(tái)主變。因此,在確保安全可靠供電的基礎(chǔ)上,確定變壓器的經(jīng)濟(jì)容量,提高網(wǎng)絡(luò)的經(jīng)濟(jì)運(yùn)行素質(zhì)將具有明顯的經(jīng)濟(jì)意義。 。 。 ;無功負(fù)荷率取 。終端變電所主要由地方變電所或發(fā)電廠供電,降壓后直接向各種用電設(shè)備供電 本次設(shè)計(jì)的變電所是高壓側(cè)為 220kV,低壓側(cè)為 60kV的終端變電所 文關(guān) 220kV 降壓變電所電氣部分初步設(shè)計(jì) 3 第二章 概 論 設(shè)計(jì)的基本要求說明 本次設(shè)計(jì)的為文關(guān) 220kV降壓變電所電氣部分初步設(shè)計(jì),電壓等級(jí)為 220/60KV, 220KV側(cè)有兩回進(jìn)線, 60kV側(cè)有配出線路 12回 ,并 出線走廊寬闊。有些變電所考慮母線的功率因數(shù)較低,還裝有電力電容器組靜止補(bǔ)償裝置或調(diào)相機(jī)等設(shè)備 上述設(shè)備中,除控制與信號(hào)部分,繼電保護(hù)裝置,測(cè)量?jī)x表,控制電源和通訊等設(shè)備外,其余部分稱為一次設(shè)備,由一次設(shè)備組成的網(wǎng)絡(luò)系統(tǒng)稱為一次系統(tǒng) 變電所的分類 按電壓的升降分類,分為升壓變電所和降壓變電所兩大類。 由于本人水平有限,設(shè)計(jì)書中難免會(huì)有錯(cuò)誤和不足之處,懇請(qǐng)老師批評(píng)指正。同時(shí)經(jīng)過變壓器的選擇和變電所所帶負(fù)荷情況,確定本變電所電氣主接線方案和高壓配電裝置及其布置方式,同時(shí)根據(jù)變電所的電壓等級(jí)及其在電力網(wǎng)中的重要地位進(jìn)行繼電保護(hù)和自動(dòng)裝置的規(guī)劃設(shè)計(jì),最后通過對(duì)主接線形式的確定及所選設(shè)備的型號(hào)繪制變電所的斷面圖、平面圖、和主接線圖,同時(shí)根據(jù)所繪制的變電所平面圖計(jì)算變電所屋外高壓配電裝置的防雷保護(hù)。s power industry development soon, since the early 1970s, the first 300 MW unit for a few shipped to the end of 1988, the 600 MW unit has been put into operation, electricity and industrial development on a new level. Capacity building of power plants has reached 2700 MW. 330 ~ 500kv power transmission system is being gradually expanded. To the end of 1991, the total installed capacity of over 150000 MW, the generation capacity has reached billion . Power system is an important energy sector in the national economy, and the electricity substation was designed in the building industry essential to a project. Design familiar with the various protocols and design principles, the design process to address the scale and form of substations, concrete analysis of concrete problems. This paper introduced the buck, Commissioner of 220 kV electric substation of the preliminary design, design tasks from the point of view, is divided into seven steps. That is, 1, choice of the main transformer substation of the models, capacity and number of Taiwan. 2, the design of the electrical substation main connection of the basic form. 3, a shortcircuit current calculation. 4, a major electrical equipment choice. 5, the highvoltage power distribution substation planning and design of the devices. 6, the substation protection and automatic devices of the planning and design. 7, Lightning Protection of the substation planning and design, such as seven steps, this paper with the electrical design on a point of order. The design is in school during the last a very important part of a prehensive practice teaching, but also full use of our students have learned basic theories, professional knowledge to practical problems to design (or research) integrated training, is also our future Jobs and to lay the basic practice. Through this design can be enhanced by the knowledge we use to explain the actual capacity and ability to innovate in order to better meet the needs of their work. The design elements associated with the reference to the preparation, the limited level, it is inevitable there will be errors of omission, please refer to the teacher to give more criticism correction. 文關(guān) 220kV 降壓變電所電氣部分初步設(shè)計(jì) V Keyword: substations, transformers, the main electrical wiring and electrical equipment, protection, mine protection. 沈陽(yáng)工程學(xué)院畢業(yè)設(shè)計(jì) VI 引 言 發(fā)電廠及電力系統(tǒng)專業(yè)的畢業(yè)設(shè)計(jì)是培養(yǎng)學(xué)生綜合運(yùn)用大學(xué)三年所學(xué)理論知識(shí),獨(dú)立分析和解決工程實(shí)際問題的初步能力的一個(gè)重要環(huán)節(jié)。其設(shè)計(jì)內(nèi)容結(jié)合相關(guān)的參考文獻(xiàn)進(jìn)行編寫,由于水平有限,難免會(huì)有錯(cuò)誤疏漏之處,請(qǐng)參閱老師多給予批評(píng)指正。 進(jìn)行本變電所繼電保護(hù)和自動(dòng)裝置的規(guī)劃設(shè)計(jì)。 設(shè)計(jì)本變電所電氣主接線的基本形式。 電力系統(tǒng)是國(guó)民經(jīng)濟(jì)的重要能源部門,而變電所的設(shè)計(jì)是電力工業(yè)建設(shè)中必不可少的一個(gè)項(xiàng)目。 我國(guó)的電力工業(yè)發(fā)展也很快,自 70年代初,第一臺(tái) 300MW機(jī)組數(shù)投運(yùn)至 1988年底,投產(chǎn) 600MW機(jī)組以來,電力工業(yè)發(fā)展又上了一個(gè)新臺(tái)階。例如,工廠中的電動(dòng)機(jī),就是將電能轉(zhuǎn)換成機(jī)械能,拖動(dòng)各種機(jī)械;又如我們常用的電燈,是將電能轉(zhuǎn)變?yōu)楣饽?,滿足照明需要。電能有許多優(yōu)點(diǎn):首先,它可簡(jiǎn)便地轉(zhuǎn)變成另一種形式的能量。因此可見,電力工業(yè)在國(guó)民經(jīng)濟(jì)中占有十分重要的地位,而且電力必須先行,才能滿足工農(nóng)業(yè)發(fā)展的需要。到 1991 年底,全國(guó)裝機(jī)總?cè)萘恳殉^ 150000MW,年發(fā)電量已達(dá) 億 kw?h。即, 選擇本變電所主變壓器的型號(hào)、容量和臺(tái)數(shù)。 進(jìn)行本變電所高壓配電裝置的規(guī)劃設(shè)計(jì)。通過本次設(shè)計(jì)可以增強(qiáng)我們運(yùn)用所學(xué)知識(shí)解釋實(shí)際問題的能力和創(chuàng)新能 力,以便更好地適應(yīng)工作的需要。 Also, we used the Electric Company, is the power to change solar energy to meet the lighting needs. Second, a highvoltage power transmission lines, but also conveying a very long distance, the distance of electricity supply. In addition, many production sectors of electricity to control, easy to aut