freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

潔凈廠房消防系統(tǒng)設(shè)計-全文預(yù)覽

2025-09-25 18:04 上一頁面

下一頁面
  

【正文】 re of fire safety system sun reasonable or loopholes, emergency firefighting is not timely, to the enterprise caused significant loss of life and property issues. Considering clean plant equipment is expensive, hightechnology elements, fire suppression difficult, general detectors,automatic fire extinguishing equipment and other factors can not be effectively applied investigation, literature, calculation, geometry mapping method, refer to the Building Fire specifications Specification , automatic fire alarm system design and other laws and regulations, scientific economy, higher safety factor for fire system design, to ensure the production space of the system is able to control the spread of fire disaster to expand to achieve the purpose of timely and efficient pletely extinguished . This design mainly in the clean room automatic fire alarm system, automatic fire extinguishing system, linkage control system three aspects make the total fire protection system design. Key words:Clean rooms Air sampling smoke detector Highpressure water mist fire extinguishing equipment Hydraulic diameter calculation System layout 目錄 第一章 概論 .................................................... 1 研究現(xiàn)狀 ............................................................. 1 潔凈廠房的基本特點 .............................................. 1 潔凈廠房消防設(shè)施設(shè)計存在的問題 .................................. 2 潔凈廠房的火災(zāi)特點 .............................................. 2 研究的意義 ........................................................... 2 研究對象概況 ......................................................... 3 第二章 設(shè)計內(nèi)容 ................................................ 7 .消防系統(tǒng)的組成 ...................................................... 7 設(shè)計對象的防護等級以及內(nèi)容確定 ....................................... 7 .............................................. 8 ........................................................ 9 第三章 火災(zāi)自動報警系統(tǒng) ....................................... 10 火災(zāi)自動報警系統(tǒng)的工作原理 .......................................... 10 火災(zāi)自動報警系統(tǒng)的形式 .............................................. 10 報警區(qū)域及探測區(qū)域的劃分 ............................................ 11 報警區(qū)域的劃分 ................................................. 11 探測區(qū)域的劃分 ................................................. 11 火災(zāi)探測器的選擇和布置 .............................................. 12 .................................................. 12 探測器的布置 ................................................... 13 探測器的連線方式 ............................................... 14 火災(zāi)顯示盤、火災(zāi)報警控制器的布置 ............................... 15 手動報警按鈕及聲光報警器的布置 ................................. 15 應(yīng)急照明及疏散設(shè)施 .................................................. 15 應(yīng)急照明的控制形式及布置 ...................................... 15 安全疏散標(biāo) 示的布置 ............................................. 16 ................................................... 16 第四章 自動滅火系統(tǒng) ........................................... 17 設(shè)計對象的實際情況 .................................................. 17 自動滅火裝置的工 作原理 .............................................. 17 自動滅火裝置布置 .................................................... 17 系統(tǒng)選型 ....................................................... 18 噴頭布置 ....................................................... 18 水力計算 ............................................................ 20 第五章 聯(lián)動控制系統(tǒng) .................................................... 23 信息傳遞方式 ........................................................ 23 控制中心聯(lián)動指令 ................................................... 23 第六章 設(shè)計結(jié)果圖及結(jié)論 ....................................... 24 參考文獻(xiàn) ...................................................... 27 謝詞 .......................................................... 28 天津理工大學(xué) 2020屆本科畢業(yè)設(shè)計說明書 1 第一章 概論 研究現(xiàn)狀 在現(xiàn)代,醫(yī)藥、電子、食品等行業(yè)迅速發(fā)展,這些行業(yè)對廠房、生產(chǎn)工序和生產(chǎn)環(huán)境的要求越來越高。 電子產(chǎn)品制造業(yè)中小型生產(chǎn)空間 消防系統(tǒng)設(shè)計 摘要 為了解決電子科技 潔凈 廠房或存儲空間內(nèi)發(fā)生火災(zāi)時因建筑物內(nèi)本質(zhì)消防安全系統(tǒng)不合理或者存在漏洞、應(yīng)急滅火不及時 ,給企業(yè)造成生命財產(chǎn)的重大損失問題。 關(guān)鍵詞 : 潔凈室 空氣采樣式感煙探測器 高壓細(xì)水霧自動滅火裝置 水力管徑計算 系統(tǒng)布置。本文就潔凈廠房的特點,提出了常規(guī)消防設(shè)施設(shè)計實際工程應(yīng)用中存在的問題,并提出了消防設(shè)施設(shè)計方案,以供指正 。一般有六級 (即十級、百級、千級、萬級、十萬級、百萬級等 )。潔凈廠房主要結(jié)構(gòu)由人員凈化室、物料凈化室、空氣吹淋室、氣閘室、空調(diào)凈化機房、輔助用房、技術(shù)管道線夾層及夾道和潔凈區(qū)等組成。電氣設(shè)備集聚較多,線路大多為暗敷,檢修比較困難,給火災(zāi)撲滅帶來較大的困難。加之廠房內(nèi)通風(fēng)管道、電氣線路套管、技術(shù)夾層等彼此串通,很容易造成煙熱氣流向其它房間快速芡延。 潔凈廠房消防設(shè)施設(shè)計存在的問題 (1)氣流組織方式特殊,普通感煙探測器基本無效 。 潔凈區(qū)有潔凈無菌的工藝要求,采用自動噴水滅火系統(tǒng)中的開式系統(tǒng),平時敞開的管道不能滿足潔凈廠房無塵無菌的要求,閉式系統(tǒng)管道中又經(jīng)常充滿滅火介質(zhì),免不了偶 有泄漏,污染空氣,在設(shè)有貴重設(shè)備、儀器的房間內(nèi)自動噴水滅火動作后還會造成二次污染,造成更大的損失。 ( 2) 火災(zāi) 蔓 延快 若干潔凈室都通過風(fēng)管彼此相連,當(dāng)發(fā)生火災(zāi),特別是初起火災(zāi)未被發(fā)現(xiàn)而 又繼續(xù)送風(fēng)的情況下,風(fēng)管成為煙、火迅速外竄,殃及其余房間的重要通道。廠房的平面布置曲折,增加了疏散路線上的障礙,延長了安全疏散的距離和時間。 研究對象概況 該廠房為某電子科技企業(yè)集成電路后工序潔凈廠房,集成電路后工序生產(chǎn)廠房主要是芯片制造好以后給芯片穿衣的過程 ,目前使用較多的是塑料封裝。 廠房概況:廠房高度: 3m (地面到天花板 ); 建筑梁底高: ; 室內(nèi)總面積: 2m ; 生產(chǎn)線部分外潔凈室 : 255 2m ; 內(nèi)潔凈室 : 90 2m ; **捆 包間 : 80 2m ;
點擊復(fù)制文檔內(nèi)容
公司管理相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1