出雙排樁的排距有合理的排距范圍。關(guān)鍵詞:雙排樁;有限差分;土壓力;數(shù)值模擬 中圖分類號:TU47 文獻(xiàn)標(biāo)識碼:ANumerical simulation on soil pressure of doublerow pile retaining structuresNIU Shuangjian1, YANG Dafang2, MA Huan1(1. School of Architecture amp。 the soil pressure before rear row pile was roughly linear distribution and consistent with the static soil pressure , upward of the excavation of foundation ditch was less than the static soil pressure, underside of the excavation of foundation ditch was greater than the static soil pressure。目前,對雙排樁的研究一般多集中在對樁頂側(cè)移、樁身內(nèi)力方面[26],很少有文獻(xiàn)研究雙排樁土壓力的分布。(2)土體為單一土層,且均質(zhì)、連續(xù)。 工程概況該基坑長50 m,寬24 m,基坑開挖深度8 m,分兩次開挖,第一次開挖3 m,第二次開挖至基坑設(shè)計(jì)標(biāo)高。樁的截面尺寸為bh= m m,E=104 MPa,μ=,樁的密度ρ為2500 kg/m3;樁頂連梁截面尺寸bh= m m, m,模型計(jì)算參數(shù)取值與混凝土樁一致,連梁與前后排樁節(jié)點(diǎn)采用剛結(jié)連接?;娱_挖土體采用零模型(Null),零模型區(qū)域的應(yīng)力被設(shè)置為零,在FLAC3D可以很好地進(jìn)行開挖、回填之類的模擬[7]。因此,在雙排樁支護(hù)結(jié)構(gòu)內(nèi)力計(jì)算時(shí),建議前排樁樁前被動土壓力取被動土壓力值?!『笈艠稑肚氨粍油翂毫笈艠稑肚氨粍油翂毫θ鐖D3所示。由圖4可知,后排樁樁后土壓力比較接近靜止土壓力分布,大于朗肯主動土壓力,在基坑開挖面以上小于靜止土壓力;在基坑開挖面以下有大于靜止土壓力的分布部分,因此在進(jìn)行雙排樁支護(hù)結(jié)構(gòu)內(nèi)力計(jì)算時(shí),建議后排樁樁后主動土壓力取值在基坑開挖面以上取靜止土壓力圖4 后排樁樁后主動土壓力Fig. 4 Active soil pressurebehind rear row pile值,在基坑開挖面以下取靜止土壓力值乘以一個(gè)大于1的系數(shù),適當(dāng)擴(kuò)大其值?!∏芭艠稑肚氨粍油翂毫Ω鞣N排距下前排樁樁前被動土壓力分布如圖6所示?!『笈艠稑肚氨粍油翂毫Ω鞣N排距下后排樁樁前被動土壓力分布如圖8所示。由圖9可知,在基坑開挖面以上隨著排距的增大,其值分布越來越接近朗肯主動土壓力值的分布;在基坑開挖面以下約4 m處,各種排距下的后排樁樁后主動土壓力值均大于靜止土壓力值,隨著排距的增大,其分布越來越接近靜止土壓力值。(2)雙排樁前排樁樁后主動土壓力大致與靜止土壓力一致,在基坑開挖面以上其值小于靜止土壓力,大于朗肯主動土壓力,在基坑開挖面以下其值大于靜止土壓力;隨著排距的增大,在基坑開挖面以上分布越來越接近朗肯主動土壓力,在基坑開挖面以下,其分布越來越接近靜止土壓力值。(5)樁間土對前后排樁樁側(cè)的土壓力大致相等,這表明由于樁頂連梁的作用,使前后排樁和樁間土成為一個(gè)整體,這就增大了其側(cè)向剛度,這就是雙排樁支護(hù)體系樁頂側(cè)向位移較單排樁小的主要原因,因此在進(jìn)行雙排樁支護(hù)體系內(nèi)力分析的時(shí)候不能把樁間土僅作為作用在樁上的外荷載,而應(yīng)該作為雙排樁支護(hù)體系的一部分加以考慮。在基坑開挖面以上其值小于靜